Description
1. Introduction
The 10 cm Guedel oropharyngeal airway (ref. 5004 / BRL5004) is an essential airway device in the basic management of breathing in large adult patients with loss of consciousness, deep sedation or general anaesthesia. Thanks to its anatomical design in semi-rigid polyethylene, sterile single-use and latex- and phthalate-free, it prevents the collapse of the tongue and soft tissues against the pharyngeal wall, ensuring a patent airway throughout the procedure. It is the ideal solution for emergency departments, intensive care, anaesthesia, cardiopulmonary resuscitation and patient transport.
2. Technical explanation of the device
The Guedel oropharyngeal airway (also known as a Mayo tube) is a curved semi-rigid tube inserted through the mouth into the oropharynx. Its anatomical curvature reproduces the morphology of the palate and pharynx, separating the tongue from the posterior pharyngeal wall and keeping the upper airway open in patients who cannot maintain it themselves. The central channel with lateral reinforcements ensures a continuous and stable airflow, while also allowing suction of secretions, while the integrated bite block protects the device from occlusion by bite pressure. Being single-use and sterile, it prevents cross-contamination between patients. It should only be used in unconscious patients or those with a depressed level of consciousness, and never in conscious patients with a gag reflex.
3. Technical Specifications
| Parameter | Specification |
| Designation | Guedel oropharyngeal cannula (oropharyngeal airway) |
| References | 5004 / BRL5004 |
| Manufacturer | Boscarol |
| Length | 10 cm (100 mm) |
| Minimum internal diameter (I.D.) | 5.0 mm |
| Material | Polyethylene (PE), latex- and phthalate-free |
| Sterility | Yes, sterile single-use device |
| Use | Single-use (disposable), prevents cross-contamination |
| Indication | Oropharyngeal airway for large adult patients |
| Applications | Emergency care, anaesthesia, ICU, CPR and medical transport |
| Regulatory standard | Medical device with CE marking |
Range of available sizes (oropharyngeal airways)
| Reference | Length | Minimum I.D. |
| BRL5000 | 6 cm | 4.0 mm |
| BRL5001 | 7 cm | 4.0 mm |
| BRL5002 | 8 cm | 4.5 mm |
| BRL5003 | 9 cm | 4.5 mm |
| BRL5004 | 10 cm | 5.0 mm |
4. Equivalences and Cross-References
There is no official equivalence table validated by the manufacturer for this reference; the following industry references are offered as a functional comparison by size (10 cm / 100 mm) and must be confirmed with the technical department before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level |
| Catalogue Cahnos | 10 cm oropharyngeal airway (this item) | 5004 / BRL5004 | Original reference |
| Cahnos | Guedel airway ISO 10 (10 cm), sterile unit | 830040M | Direct size equivalent |
| Cahnos | Soft Guedel airway ISO 10, flexible | SGU241100 | Comparable by category |
| Cahnos | Fibre-optic Guedel airway ISO 10 | SLT253100 | Comparable by category |
| Intersurgical | One-piece Guedel airway, size 4, ISO 10 | 1114100 | Functional equivalence by size |
| Gima | Guedel Airway 100 mm | 57757 | Comparable by category |
| Teleflex / Rüsch | Color-Coded Guedel Airway 100 mm | 1224100 | Comparable by category |
| McKesson | Guedel Oropharyngeal Airway 100 mm, ISO 10 | 485078 | Comparable by category |
Sizing note: the classic numbering varies by manufacturer (100 mm may be associated with size 4 or size 5). Always verify the length in millimetres, the material, sterility and the bite block design before replacing a reference in your airway trolley.
5. Selection tips and variants of interest
To choose the correct Guedel airway size, measure the distance between the labial commissure and the angle of the patient’s mandible: the length of the airway should approximate this distance without exceeding it. The 10 cm (100 mm) size fits large adults; complete your stock with the adjacent sizes of 9 cm (ref. BRL5003) and the 7 and 8 cm sizes (ref. BRL5001 and BRL5002) to cover all cases in your department. Before insertion, lubricate the airway and insert it with a 180-degree rotation to minimise trauma. Consult our technical-commercial team for volumes, supply conditions and airway kits tailored to your anaesthesia, emergency, ICU or patient transport department.




Reviews