Description
1. Introduction
The oral tracheal endotracheal tube without cuff and with Murphy eye of ID 2.5 mm (Ref. ETAN25002) is the airway solution that anaesthesia, emergency and intensive care services need to guarantee ventilation of their patients when the face mask is not a viable option. Made of medical-grade polyvinyl chloride (PVC), latex-free and transparent, it combines durability, controlled flexibility and biocompatibility for critical procedures in small-sized patients. It is presented in a box of 10 units, individually packaged and sterile, designed to maintain a hospital stock always available in high-turnover units such as the NICU, the paediatric operating theatre and emergency bays.
2. Technical explanation of the equipment and procedure
In orotracheal intubation, the tube is introduced through the mouth under laryngoscopic vision, passes through the glottis and is placed in the trachea, where it conducts gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. As it is a cuffless tube, sealing is achieved by the anatomical fit of the calibre against the tracheal wall, so it is especially indicated when cuff inflation is contraindicated or not necessary, a common practice in small-calibre airways and in neonatal and paediatric patients.
The Murphy eye, a lateral opening located at the distal end, acts as an alternative ventilation pathway: if the main lumen were obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening, ensuring continuity of ventilation. The Magill-type curvature, the rounded atraumatic tip, the radiopaque contrast line and the depth marks facilitate safe placement and radiographic verification. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference (SKU) | ETAN25002 (Cahnos own code Cahnos) |
| Type | Oral endotracheal tube (orotracheal), Magill curve |
| Access route | Oral |
| Internal diameter (ID) | 2.5 mm |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, flexible and durable |
| Latex | Natural latex-free |
| Sleeve | Cuffless (sealed by anatomical fit of the size) |
| Murphy eye | Present, distal lateral safety orifice |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth markings |
| Sterilisation | Ethylene oxide (EO), sterile, individually packaged |
| Use | Single-use, disposable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
The ETAN series of oral tracheal tubes without cuff with Murphy eye, to which this reference belongs, covers the following calibres in the same configuration and presentation:
| Inner diameter | Reference (box of 10 units) |
|---|---|
| 2.0 mm | ETAN20002 |
| 2.5 mm | ETAN25002 (this product) |
| 3.0 mm | ETAN30002 |
| 3.5 mm | ETAN35002 |
| 4.0 mm | ETAN40002 |
| 4.5 mm | ETAN45002 |
| 5.0 mm | ETAN50002 |
| 5.5 mm | ETAN55002 |
| 6.0 mm | ETAN60002 |
| 6.5 mm | ETAN65002 |
| 7.0 mm | ETAN70002 |
| 7.5 mm | ETAN75002 |
| 8.0 mm | ETAN80002 |
| 8.5 mm | ETAN85002 |
| 9.0 mm | ETAN90002 |
| 9.5 mm | ETAN95002 |
| 10.0 mm | ETAN10002 |
Note: tracheal tubes are manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the declaration of conformity and the CE/MDR marking of the manufacturer on each supplied batch. The outer diameter (OD) and total length in this calibre could not be verified in official public sources from the manufacturer; they are pending confirmation with the technical department before use in tenders or stock replacement.
4. Equivalences and Cross-References
The SKU ETAN25002 is Cahnos’ own code in the catalogue and the ETAN family follows the nomenclature of the DEAFLUX line of Magill-type tracheal tubes; it should not be confused with the official part number of any specific manufacturer. Therefore, an exact reference equivalence cannot be declared.
- Comparable confirmed in Cahnos’ own catalogue (same configuration: Magill without cuff with Murphy eye, calibre 2.5 mm): endotracheal tube ENDOSID Magill without cuff with Murphy eye Ref. 843025, which shares indication, calibre and general geometry; it may differ in manufacturer and supply format.
- Category-level comparables (same type of product and clinical indication, not interchangeable 1:1): Magill-type tracheal tube without cuff with Murphy eye from P. J. Dahlhausen, series 44.000.11.025 (series documented in the manufacturer’s official catalogue for this calibre), and cuffless tubes from the Safety Clear® ranges of Teleflex/Rüsch (consult exact code for 2.5 mm) and ICU Medical/Portex. They may differ in PVC compound, length, outer diameter, distal profile and bevel design.
- Complementary references of the same 2.5 mm calibre in the Cahnos catalogue: 840025 (standard Magill without cuff), 842025 (without cuff and without Murphy eye), 843025 (without cuff with Murphy eye), 845025 (emergency intubation kit) and ETAN25C02 (version with cuff and Murphy eye).
There is no equivalence table validated by the manufacturer for this generic distributor reference; consult with the technical department of Cahnos before using this reference as an equivalence in specifications, tenders or direct replacement of another brand.
5. Selection tips and variants of interest
Calibre selection (usual practice in clinical use, not manufacturer specification): the ID 2.5 mm calibre is intended for neonates and premature infants; as a general guide, in premature infants and neonates calibres from 2.0 to 3.5 mm are used according to gestational age, weight and service protocol. As it lacks a cuff, special attention must be paid to the fit of the tube in the trachea to minimise leaks and risk of aspiration in protocols where sealing is critical.
Verification before intubation: check the integrity of the tube, the patency of the Murphy eye and the correct attachment of the 15 mm connector to the circuit; after placement, confirm the position using the radiopaque line and depth marks. Single-use product: do not re-sterilise or reuse.
Variants of interest in the Cahnos catalogue: if you require an airtight seal or prolonged ventilation, consider the cuffed version of the same size (Ref. ETAN25C02); in the event of a risk of kinking or external compression, consult the reinforced ranges in the intubation section; and to complete the intubation trolley, the emergency kits from the 8450xx series. If you need another size, the uncuffed ETAN series covers from 2.0 mm to 10.0 mm (ETAN20002 to ETAN10002) in the same configuration. Contact the technical-commercial department at Cahnos for samples, volume terms and the approval of references for your tender.



Reviews
There are no reviews yet.