Description
1. Introduction
The oral tracheal endotracheal tube without cuff and with Murphy eye, internal diameter 7.5 mm (Ref. ETAN75002), is the airway solution that anaesthesia, emergency and intensive care services need to ensure patient ventilation when the use of a face mask is not viable. Manufactured in medical-grade polyvinyl chloride (PVC), it offers durability, controlled flexibility and compatibility with the safety standards required in critical procedures. It is supplied in a box of 10 units, designed to keep hospital stock always available.
2. What it is and how it works
In orotracheal intubation, the tube is inserted through the mouth under laryngoscopic vision, passes through the glottis and is placed in the trachea to conduct gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. As it is a tube without a cuff, sealing is achieved by the anatomical fit of the tube against the tracheal wall, so it is especially indicated when cuff inflation is contraindicated or not necessary. The Murphy eye, a lateral opening located in the distal area, acts as an alternative ventilation route: if the main lumen were obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening. The Magill curve, the rounded atraumatic tip, the radiopaque line and the depth marks facilitate safe placement and verification. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.
3. Technical Specifications
The specifications set out below correspond to the technical data published for this reference in the Cahnos catalogue:
| Parameter | Specification |
|---|---|
| Reference | ETAN75002 |
| Type | Oral endotracheal (orotracheal), Magill curve |
| Sleeve | Without sleeve |
| Murphy eye | Present, distal lateral safety orifice |
| Internal diameter (ID) | 7.5 mm (standard adult size) |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque line and depth marks |
| Use | Single-use |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
ETAN series (oral tracheal tubes without cuff with Murphy eye): the family to which this reference belongs covers the following sizes documented in the catalogue, all with the same configuration and presentation in boxes of 10 units:
| Inner diameter | Reference (box of 10 units) |
|---|---|
| 2.0 mm | ETAN20002 |
| 2.5 mm | ETAN25002 |
| 3.0 mm | ETAN30002 |
| 3.5 mm | ETAN35002 |
| 4.0 mm | ETAN40002 |
| 4.5 mm | ETAN45002 |
| 5.0 mm | ETAN50002 |
| 5.5 mm | ETAN55002 |
| 6.0 mm | ETAN60002 |
| 6.5 mm | ETAN65002 |
| 7.0 mm | ETAN70002 |
| 7.5 mm | ETAN75002 (this product) |
| 8.5 mm | ETAN85002 |
| 9.0 mm | ETAN90002 |
| 9.5 mm | ETAN95002 |
| 10.0 mm | ETAN10002 |
Note: verify the manufacturer’s declaration of conformity and CE/MDR marking on each supplied batch before use in procedures. Tracheal tubes are manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors); confirm on the batch labelling.
4. Equivalences and Cross-References
The SKU ETAN75002 is Cahnos’s own code (ETAN series) for this generic oral tracheal tube in PVC; the ETAN family follows the nomenclature of the DEAFLUX line from DEAS S.r.l., but it must not be confused with the official reference number of any other manufacturer. To date, there is no manufacturer-validated equivalence table for this reference, so we classify the following options as comparable at category level (not interchangeable 1:1), pending technical verification against each manufacturer’s official data sheet:
- Dahlhausen, Magill tube without cuff, ID 7.5 mm: ref. 4400011075, confirmed in the manufacturer’s online catalogue: tube without cuff with graduation, Murphy eye, radiopaque line and MRI compatible. Same configuration and size; manufacturer and supply format differ.
- ETA075002A2 – reinforced oral endotracheal tube without cuff with Murphy eye, ID 7.5 mm (Cahnos catalogue): same size and configuration, but with spiral reinforcement providing greater kink resistance; differs in construction and price.
- ETAN75C02 – oral endotracheal tube with cuff and Murphy eye, ID 7.5 mm (Cahnos catalogue): same size and base design, but incorporates a cuff for an airtight seal; it is not interchangeable with the cuffless version.
- ETSL75C02 – oral endotracheal tube with cuff and subglottic suction lumen, ID 7.5 mm (Cahnos catalogue): adds subglottic suction for prolonged ventilation.
- 840075 – ENDOSID Magill endotracheal tube without balloon, ID 7.5 mm (Cahnos catalogue): same functional category, another product family.
- At market level, 7.5 mm cuffless tubes fall into the same functional category as the Teleflex (Rüsch®), Medtronic (Shiley™), ICU Medical (Portex®) or Intersurgical lines: same general clinical indication, but it is essential to verify in each technical data sheet the internal diameter, material, presence of Murphy eye and sterilisation standard before replacing the device in a care protocol.
There is no manufacturer-validated equivalence table for this reference; consult the Cahnos technical department before using this reference as an equivalence in tenders or bids.
5. Selection tips and variants of interest
Size selection (usual practice in clinical practice, not manufacturer specification): the cuffless tube is frequently used in patients in whom cuff inflation is contraindicated or in procedures of limited duration. As a general guide, in adults tubes of 7.0 to 9.0 mm are used according to age, weight and build (7.0–7.5 mm in women or medium build and 7.5–8.5 mm in men), always selecting the largest size compatible with the patient’s anatomy. The final choice must be based on the service protocol and the patient’s anaesthetic assessment.
Verification before intubation: check the integrity of the tube, the patency of the Murphy eye and the correct attachment of the connector. As it lacks a cuff, special attention must be paid to the fit of the tube in the trachea to minimise leaks and the risk of aspiration in protocols where sealing is critical.
Variants of interest in the catalogue: if you need another size, the ETAN series covers from 2.0 mm to 10.0 mm (ETAN20002 to ETAN10002). For procedures requiring an airtight seal or prolonged ventilation, consider the cuffed tube (Ref. ETAN75C02) or with subglottic suction (Ref. ETSL75C02); in case of risk of kinking or external compression, the spiral-reinforced one (Ref. ETA075002A2); and for head and neck surgery or nasal airways, consult the preformed lines in the catalogue. Contact the technical-commercial department of Cahnos for samples, volume conditions and the approval of references for your tender.




Reviews