Description
1. Introduction
The reinforced oral endotracheal tube with cuff, insertion stylet and Murphy eye of 6.0 mm internal diameter (ref. ETAM60C02A1) is a single-use medical device designed to ensure a patent and stable airway in critical situations: positive-pressure ventilation, administration of general anaesthesia and management of the patient in intensive care when mask ventilation is not possible. Its helical reinforcement wire makes it the reference option when tube movement, special positioning, head and neck surgery or risk of kinking are anticipated.
With an internal diameter of 6.0 mm, this size is intended for tall paediatric patients or small-built adults. It is supplied in a box of 10 units, ready for restocking intubation trolleys, ICU bays and operating theatres, ensuring a uniform and reliable standard in every airway procedure.
2. Technical explanation of the device and procedure
Orotracheal intubation involves introducing the tube orally, through the glottis, until its distal end is placed in the trachea, below the vocal cords. The included insertion stylet facilitates advancement and correct positioning, providing controlled rigidity during the manoeuvre and being removed once the tube is placed.
The reinforced body (helical spiral integrated into the PVC wall) prevents tube collapse under external compression, biting or kinking, maintaining airway patency in complex positions. The cuff, inflated via the pilot balloon with Luer connection, seals the tracheal lumen and allows positive-pressure ventilation without leaks, as well as preventing aspiration of secretions. The Murphy eye, a lateral opening near the distal tip, acts as a safety pathway: if the tip rests against the tracheal or bronchial wall, respiratory flow continues through that opening, avoiding total occlusion. The proximal end connects to the ventilator, anaesthesia circuit or resuscitation bag via the universal 15 mm connector conforming to ISO 5356-1, and the radiopaque line allows position verification by radiography.
3. Technical Specifications
Technical data corresponding to the data sheet for this reference in the Cahnos catalogue:
| Parameter | Specification |
|---|---|
| Reference | ETAM60C02A1 |
| Type | Reinforced oral endotracheal tube with cuff |
| Internal diameter (ID) | 6.0 mm |
| Access route | Oral (orotracheal) |
| Material | Medical-grade polyvinyl chloride (PVC), transparent |
| Reinforcement | Integrated helical spiral, kink resistance |
| Insertion guide | Yes, included |
| Sleeve | Cuffed, inflated via pilot balloon with Luer connection |
| Murphy eye | Present (distal lateral safety opening) |
| Connector | Universal 15 mm (ISO 5356-1) |
| Radiopacity | X-ray contrast line |
| Latex | Natural rubber latex-free |
| Sterility | Sterile, individually packaged (ethylene oxide, according to EN ISO 11135-1) |
| Use | Single-use, non-reusable |
| Indications | Positive pressure ventilation and anaesthesia administration |
| Presentation | Box of 10 units |
This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the declaration of conformity and the manufacturer’s CE marking on each supplied batch before use in procedures.
Range of sizes available from Cahnos (ETAM family, reinforced with cuff and guide):
| Reference | Internal diameter (ID) | Indicative patient |
|---|---|---|
| ETAM30C02A1 | 3.0 mm | Newborn |
| ETAM35C02A1 | 3.5 mm | Newborn |
| ETAM45C02A1 | 4.5 mm | Child |
| ETAM50C02A1 | 5.0 mm | Child |
| ETAM55C02A1 | 5.5 mm | Child / small adult |
| ETAM60C02A1 (this product) | 6.0 mm | Small adult |
| ETAM65C02A1 | 6.5 mm | Small adult |
| ETAM70C02A1 | 7.0 mm | Adult |
| ETAM75C02A1 | 7.5 mm | Adult |
| ETAM80C02A1 | 8.0 mm | Adult |
| ETAM85C02A1 | 8.5 mm | Adult / large adult |
| ETAM90C02A1 | 9.0 mm | Large adult |
| ETAM95C02A1 | 9.5 mm | Large adult |
| ETAM10C02A1 | 10.0 mm | Very large adult (exceptional size) |
4. Equivalences and Cross-References
Functional equivalence by category (not interchangeable 1:1). By clinical indication (reinforced oral endotracheal tube with cuff, stylet and Murphy eye, ID 6.0 mm), this product is comparable to reinforced tubes from manufacturers such as Teleflex (Rüsch® / Safety-Flex line), Medtronic (Shiley™ / Mallinckrodt™) and ICU Medical (Portex® Blue Line®). All these brands offer oral tubes reinforced with helical wire to resist compression, but they differ in outer diameter (OD), total length, distal tip geometry and cuff characteristics, so they must be compared specification by specification before replacing a specific product. Specific third-party codes must be verified against the manufacturer before any substitution.
The reference ETAM60C02A1 is a proprietary code of the Cahnos range; it does not correspond to an official manufacturer part number published in public sources, so it must be treated as an internal distributor reference and verified before use in tenders that require the manufacturer’s code. There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using it in a tender or as a stock replacement.
Comparable by category within the Cahnos catalogue (same ID 6.0 mm, other configurations):
| Reference | Description |
|---|---|
| ETA060C02A2 | Reinforced oral endotracheal tube with cuff and Murphy eye, without stylet |
| ETA060002A2 | Reinforced oral endotracheal tube without cuff, with Murphy eye |
| ETSL60C02 | Oral endotracheal tube with cuff and subglottic suction lumen |
| ETAN60C02 | Oral endotracheal tube with cuff and Murphy eye, without reinforcement (pending confirmation) |
| ETPN60C02 | Preformed nasal tracheal tube with cuff and Murphy eye (pending confirmation) |
These references are comparable at category level, not interchangeable 1:1: each configuration addresses a specific indication (reinforcement, stylet, subglottic suction, nasal route, etc.).
5. Selection tips and variants of interest
The 6.0 mm ID is reserved for tall paediatric patients or small-built adults; as a general guide, in adults tubes of 7.0 to 9.0 mm are used depending on build, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.
Before insertion, check the integrity of the cuff and pilot balloon and control the sealing pressure with a manometer, keeping it within the usual clinical range (indicative 20–30 cmH₂O; common market practice, confirm the service protocol).
The reinforced tube with stylet is especially indicated when frequent repositioning, prone positioning, head and neck surgery or risk of kinking are anticipated. If intubation is to be prolonged and there is a risk of ventilator-associated pneumonia (VAP), consider the range with subglottic suction lumen (ETSL60C02). For procedures where a stylet is not required, the standard reinforced ETA060C02A2 can be selected; for nasal approaches, the preformed ETPN60C02.
For volume conditions, samples or hospital supply lead times, contact the technical and commercial department of Cahnos.