Description
1. Product description
The reinforced oral endotracheal tube with cuff and Murphy eye, internal diameter 7.5 mm (ref. ETA075C02A2), is a single-use airway management device designed for orotracheal intubation of adult patients in the operating theatre, intensive care units, emergency departments and resuscitation. Its structure reinforced with a helical spiral makes it the reference option when stability of the airway is required during head and neck movements, frequent repositioning or prolonged positive-pressure ventilation. It is supplied in a box of 10 units with individual sterile packaging, ideal for restocking the intubation trolley and the department’s stock.
2. Technical explanation of the device and procedure
Orotracheal intubation involves inserting the tube orally, through the glottis, until its distal end is positioned in the trachea, below the vocal cords. The proximal end is connected to the ventilator, the anaesthesia circuit or the resuscitation bag via the universal 15 mm connector, in accordance with ISO 5356-1.
The reinforced body incorporates a helical spiral in the PVC wall that prevents the tube from collapsing under external compression, biting or kinking, maintaining airway patency in complex positions. The high-volume, low-pressure cuff, inflated via the pilot balloon, seals the tracheal lumen and allows positive-pressure ventilation without leaks, as well as preventing aspiration of secretions and tube displacement. The Murphy eye, a lateral opening located near the distal tip, acts as a safety route: if the tip rests against the tracheal or bronchial wall, respiratory flow continues through this opening, preventing total occlusion.
3. Technical Specifications
| Parameter | Specification |
| Reference | ETA075C02A2 |
| Type | Reinforced oral endotracheal tube with cuff and Murphy eye |
| Access route | Oral (orotracheal intubation), Magill-type curvature |
| Internal diameter (ID) | 7.5 mm, standard size commonly used in adults |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free and DEHP-free |
| Reinforcement | Helical spiral integrated into the wall; prevents collapse and kinking during positive-pressure ventilation |
| Sleeve | Sealing, high volume and low pressure, with pilot balloon and valve |
| Murphy eye | Yes, distal lateral safety opening |
| Connector | Universal 15 mm (ISO 5356-1) |
| Marking | Radiopaque line and depth graduation |
| Use | Single-use, non-reusable |
| Sterilisation | Sterile, individually packaged (ethylene oxide) |
| Indication | Positive-pressure ventilation and administration of general anaesthesia when a face mask is not viable |
| Presentation | Box of 10 units |
Range of sizes available at Cahnos (ETA family, reinforced with cuff):
| Reference | Internal diameter (ID) |
| ETA035C02A2 | 3.5 mm |
| ETA045C02A2 | 4.5 mm |
| ETA055C02A2 | 5.5 mm |
| ETA065C02A2 | 6.5 mm |
| ETA075C02A2 (this product) | 7.5 mm |
| ETA080C02A2 | 8.0 mm |
| ETA085C02A2 | 8.5 mm |
| ETA090C02A2 | 9.0 mm |
| ETA095C02A2 | 9.5 mm |
| ETA010C02A2 | 10.0 mm |
4. Equivalences and Cross-References
The reference ETA075C02A2 is a code specific to the Cahnos catalogue and could not be cross-checked against an official third-party manufacturer code in public sources: there is no manufacturer-validated equivalence table; consult the Cahnos technical department before using it in tenders or as a replacement for stock from other brands. The references listed below are offered as a functional category comparison, not interchangeable 1:1, and must be confirmed on a specification-by-specification basis (external diameter, material, distal geometry, cuff characteristics and sterilisation standard) before replacing the device in a clinical protocol.
| Reference / Line | Description | Comparison status |
| Teleflex (Rüsch® / Sheridan®), family of reinforced oral tubes with cuff | Oral tubes reinforced with a stainless steel spiral in the wall, cuff and Murphy eye, size 7.5 mm | Functional category comparison without a specific verified code; cross-check specification by specification |
| Medtronic Shiley™ / Mallinckrodt™, reinforced oral-nasal tubes with cuff | Flexible PVC tube with reinforced spiral and Murphy eye, indicated for head and neck surgery | Not verified as a direct equivalent; distributor source, confirm with the manufacturer before use |
| ICU Medical / Portex™ Blue Line®, reinforced tubes with cuff | Range of oral tubes reinforced with helical reinforcement and sealing cuff | Functional category comparison without a specific verified code; cross-check specification by specification |
| Dahlhausen, line of reinforced endotracheal tubes with cuff | Series with spiral reinforcement, inflation balloon and Murphy eye in size 7.5 mm | Series documented in the manufacturer’s official catalogue; comparable by category, not interchangeable 1:1 |
| ENDOSID® (Asid Bonz / Medline), reinforced tubes with cuff | Reinforced spiral tubes, Magill type, with high-volume low-pressure cuff and Murphy eye | Functional category comparison; verify geometry and length before replacing |
Comparable by category within the Cahnos catalogue (same ID 7.5 mm, other configurations):
| Reference | Description |
| ETAM75C02A1 | Reinforced oral endotracheal tube with cuff and insertion guide |
| ETA075002A2 | Reinforced oral endotracheal tube, without cuff, with Murphy eye |
| ETAN75C02 | Oral endotracheal tube with cuff and Murphy eye, without reinforcement |
| ETSL75C02 | Oral endotracheal tube with cuff and subglottic suction lumen |
| ETPO75C02 / ETPN75C02 | Preformed oral / nasal tubes with cuff and Murphy eye |
Fields checked before comparing: internal diameter (7.5 mm), material (medical-grade PVC), cuff type (high volume/low pressure), presence of Murphy eye, helical reinforcement and 15 mm connector. Any difference in these fields places the comparison at the category level, not exact equivalence.
5. Selection tips and variants of interest
The 7.5 mm ID is a size commonly used in adult patients; as a general guide, tubes of 7.0 to 9.0 mm are used in adults depending on build and airway, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.
Before insertion, check the integrity of the cuff, the pilot balloon and the patency of the lumen. Control the cuff sealing pressure with a manometer and keep it within the usual clinical range (indicative 20–30 cmH₂O; common market practice, confirm the service protocol).
This reinforced model is the right choice when frequent repositioning, prone positioning, head and neck surgery or a risk of kinking are anticipated. If an insertion guide is also required, there is the guided version (ETAM75C02A1); if the protocol prefers to avoid the balloon, the reinforced variant without cuff (ETA075002A2); if intubation is to be prolonged and there is a risk of ventilator-associated pneumonia, consider the range with subglottic suction lumen (ETSL75C02); and for nasal approaches or ENT/maxillofacial surgery, the preformed ones (ETPO75C02, ETPN75C02).
For volume conditions, samples or hospital supply deadlines, contact the technical and commercial department of Cahnos.