We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Endotracheal Tube with Cuff CH 5.0 mm (Ø 5.0 x 245 mm), ISO Connector, Radiopaque, Atraumatic Tip, Sterile | Ref. 11814102007

Price on request

Endotracheal tube with cuff in CH 5.0 mm size (Ø 5.0 x 245 mm) from the manufacturer, indicated for orotracheal intubation in hospital, surgical and emergency settings. Manufactured in plastic material, it incorporates a sealing cuff with one-way valve, standard connector in accordance with ISO standards, reference marks, radiopaque band and atraumatic tip to minimise trauma to the airways. It is supplied in individual sterile packaging, ensuring patient safety in each procedure. Manufacturer’s reference: 11814102007 (BRL11814102007). For large orders you can request a quote: contact our technical-commercial department for supply conditions and volumes.

International shipping. Import duties and taxes are payable by the recipient.

Reference
BRL11814102007

Description

1. Introduction

The CH 5.0 mm cuffed endotracheal tube (Reference 11814102007 / BRL11814102007) is the airway solution that your anaesthesia, intensive care and emergency department needs to ensure safe intubation and effective ventilation when face mask ventilation is not viable. Manufactured in plastic material, it combines a reliable sealing cuff with a design aimed at minimising airway trauma: reference marks to control insertion depth, a radiopaque band to verify position and an atraumatic tip. It is presented in sterile packaging, ready for use in each procedure.

2. Technical explanation of the equipment and procedure

In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and is placed in the trachea, below the vocal cords, conducting gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. The sealing cuff is inflated through the one-way valve (pilot balloon), isolating the airway, preventing gas leaks and reducing the risk of aspiration of secretions during positive-pressure ventilation. The standard connector in accordance with ISO standards allows it to be universally connected to ventilation circuits.

The reference marks and radiopaque marking facilitate both control of insertion depth and radiographic verification of position after placement. The atraumatic tip, rounded and non-injurious, reduces the risk of damage to the tracheal mucosa during the manoeuvre. As it is a sterile-packaged device, the risk of contamination before use is eliminated.

3. Technical Specifications

The specifications listed below correspond to the technical data published by the manufacturer for this reference:

Parameter Specification
Manufacturer reference 11814102007 (BRL11814102007)
Type Endotracheal tube with cuff, in plastic material
Valve Unidirectional
Connector Standard, in accordance with ISO standards
Marking Reference marks; radiopaque
Tip Atraumatic
Presentation Sterile-packed
Size Ø 5.0 x 245 mm (CH 5.0)

4. Equivalences and Cross-References

This product is identified by the references 11814102007 and BRL11814102007, corresponding to the manufacturer’s catalogue and its distribution by Cahnos. In the official sources consulted, no equivalence table validated by the manufacturer has been found for this specific reference (endotracheal tube with cuff, CH 5.0 mm, Ø 5.0 x 245 mm); therefore, any substitution with a code from another manufacturer must be checked feature by feature (size, length, cuff type, connector and standards) with the Cahnos technical department before use in tenders or stock replenishment.

5. Selection tips and variants of interest

The CH 5.0 mm size (Ø 5.0 mm) is intended for paediatric patients and reduced-calibre airways; always select the largest size compatible with the patient’s anatomy and the service protocol, bearing in mind that an inappropriate size can cause leaks or mucosal damage. Before intubation, check the integrity of the cuff, the patency of the lumen, the correct attachment of the connector and the sterility expiry date; after placement, inflate the cuff with the minimum effective volume and verify the position using the reference marks and radiographic control.

If your protocol prefers to avoid the cuff, consider the range of uncuffed endotracheal tubes in the Cahnos catalogue; to complete the intubation trolley, cover the adjacent sizes in the series. Sterile-packaged device: once opened, use it in the same procedure and discard it after removal according to the centre’s healthcare waste management protocols. For samples, volume conditions or supply lead times, contact the Cahnos technical-commercial department.

Additional information

Product type

Endotracheal tube with cuff (pneumatic cuff)

Gauge

CH 5.0 mm

Measurements

Ø 5.0 x 245 mm

Valve

Unidirectional

Connector

Standard in accordance with ISO standards

Marking

Reference marks; radiopaque

Tip

Atraumatic

Sterilisation

Yes, sterile-packed

References

11814102007, BRL11814102007

Material

Plastic

Documentation

Reviews

There are no reviews yet.

Be the first to review “Endotracheal Tube with Cuff CH 5.0 mm (Ø 5.0 x 245 mm), ISO Connector, Radiopaque, Atraumatic Tip, Sterile | Ref. 11814102007”

Your email address will not be published. Required fields are marked *