Description
1. Introduction
The Right Double-Lumen Bronchial Tube ENDOSID® by Medline is an advanced airway management device designed for one-lung ventilation in anaesthesia and thoracic surgery procedures. It incorporates sealing cuffs at both tracheal and bronchial levels, allowing one lung to be isolated and the other selectively ventilated with total reliability. It is supplied in a set that includes two suction catheters and is available in six different sizes to suit each patient’s anatomy.
2. Technical explanation of the equipment
The PVC double-lumen endotracheal tube is equipped with angled connectors at its distal end, designed to easily attach to the ventilation circuit tubing and securely lockable via a rotating knob. In this way, each of the lumens can be manually opened or closed according to the anaesthetist’s needs, allowing ventilation to be alternated between both lungs or selective ventilation to be applied. The need to use Magill forceps to open or close the lumen is now obsolete: the clear markings on the rotating handle facilitate a safe and reproducible opening and closing process. Its right directional configuration (Tip Direction: Right) makes it ideal for selective intubation of the right main bronchus.
3. Technical Specifications
| Reference | Diameter | Units per box | Units per pack |
|---|---|---|---|
| 847032-RZ | CH32 | 10 | 1 |
| 847035-RZ | CH35 | 10 | 1 |
| 847039-RZ | CH39 | 10 | 1 |
| 847041-RZ | CH41 | 10 | 1 |
| 847035ARZ | CH35 | 10 | 1 |
| 847028ARZ | CH28 | 10 | 1 |
| 847032ARZ | CH32 | 10 | 1 |
| 847037ARZ | CH37 | 10 | 1 |
| 847039ARZ | CH39 | 10 | 1 |
| 847041ARZ | CH41 | 10 | 1 |
General specifications from the manufacturer’s catalogue:
- Direction: Right (selective for right bronchus)
- Single-use: Yes
- Material: PVC
- Includes: Set with two suction catheters
4. Equivalences and Cross-References
This product belongs to the Medline P-BA19U family (Right Double-Lumen Bronchial Tube ENDOSID®), marketed under the references 847032-RZ, 847035-RZ, 847039-RZ, 847041-RZ, 847035ARZ, 847028ARZ, 847032ARZ, 847037ARZ, 847039ARZ and 847041ARZ, as well as its distribution codes MDL8470xx-RZ / MDL8470xxARZ. There is no 1:1 equivalence table validated by the manufacturer against double-lumen tubes from other brands: each manufacturer applies its own curvature geometries, sizes and connection systems, so any substitution in tenders must be checked field by field with the technical department of Cahnos. Within the catalogue itself, the Endosid family includes other comparable airway management products by category (e.g., endotracheal tube with cuff and Murphy eye, ref. 841045).
5. Selection tips and variants of interest
Select the size according to the patient’s anatomy and estimated airway size: six sizes are available (CH28, CH32, CH35, CH37, CH39 and CH41), covering from smaller patients to large-built adults. This right directional model is indicated when selective intubation of the right main bronchus is required; for left-sided approaches, consider the corresponding left double-lumen tube version. Always verify proper sealing of both cuffs and patency of the lumens before starting one-lung ventilation. For institutional orders, tenders and purchasing groups, contact the technical-commercial department of Cahnos: we have the official technical data sheet and conformity documentation to validate the references in specifications and tenders.