We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 5.5 mm | Medical-Grade PVC, Sterile, Single-Use | Ref. ETA055C02A2 | Box of 10 units

99,80 €

Reinforced orotracheal endotracheal tube with cuff and Murphy eye, internal diameter 5.5 mm (Ref. ETA055C02A2), made of medical-grade polyvinyl chloride (PVC), transparent and latex-free. Its anti-kink helical spiral keeps the airway patent during head and neck movements, external compression or complex surgical positions, while the sealing cuff with pilot balloon and self-sealing valve ensures a tight and safe seal during positive-pressure ventilation and anaesthesia administration when face mask use is not feasible. Includes universal 15 mm connector (ISO 5356-1), radiopaque line and depth graduation for position control. Presentation in a box of 10 individually packaged units, sterile and single-use; verify the CE/MDR marking of each batch before use.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETA055C02A2

Description

1. Introduction

The reinforced oral endotracheal tube with cuff and Murphy eye of 5.5 mm (Ref. ETA055C02A2) is the airway solution that anaesthesia, emergency and intensive care services need when face-mask ventilation is not viable. Manufactured in medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the strength of the helical anti-kink reinforcement with the airtight sealing of the cuff and the safety of the Murphy eye, providing a patent and stable airway during critical procedures. It is supplied in a box of 10 individually packaged units, designed for the intubation trolley and high-turnover hospital consumables.

2. Technical explanation of the equipment and procedure

In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and sits in the trachea below the vocal cords, conducting gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. The helical reinforcement integrated into the PVC wall prevents tube collapse under external compression, biting or kinking, making it especially suitable for head and neck surgery, ENT, maxillofacial, thyroid, prone positioning and complex surgical positions.

The sealing cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of secretions and stabilises the device during positive-pressure ventilation. The Murphy eye, a distal lateral opening, acts as a safety route: if the tip of the tube becomes obstructed by secretions or rests against the tracheal wall, respiratory flow continues through that opening and occlusion is never complete. The universal 15 mm connector, radiopaque line and depth graduation allow connection to the circuit and radiographic verification of position. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.

3. Technical Specifications

The specifications set out below correspond to the technical data published for this reference in the Cahnos catalogue:

Parameter Specification
Reference (SKU) ETA055C02A2 (Cahnos distributor’s own code; ETA series reinforced with cuff, without guide)
Type Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced
Access route Oral (orotracheal)
Internal diameter (ID) 5.5 mm
Reinforcement Anti-kink helical spiral integrated into the tube wall
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Sleeve Sealing (cuff inflation), with pilot balloon and self-sealing valve
Murphy eye Present (distal lateral safety opening)
Tip Atraumatic, rounded and gently bevelled
Connector Universal 15 mm, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque contrast line and depth graduation
Sterilisation Ethylene oxide (EO), sterile, individually packaged
Use Single-use, non-reusable
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Indicative population Older child, adolescent or adult with a reduced-calibre airway
Presentation Box of 10 units
Regulatory standard ISO 5361 (tracheal tubes); connector ISO 5356-1; verify CE/MDR marking of each batch

Range of sizes documented in Cahnos (ETA…C02A2 series, reinforced with cuff and Murphy eye, without guide):

Reference Internal diameter (ID) Indicative patient
ETA035C02A2 3.5 mm Newborn
ETA045C02A2 4.5 mm Child
ETA055C02A2 (this product) 5.5 mm Older child / adolescent / adult with reduced airway
ETA065C02A2 6.5 mm Small adult
ETA075C02A2 7.5 mm Adult
ETA080C02A2 8.0 mm Adult
ETA085C02A2 8.5 mm Adult / large adult
ETA090C02A2 9.0 mm Large adult
ETA095C02A2 9.5 mm Large adult
ETA010C02A2 10.0 mm Large adult

Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthesia equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the declaration of conformity, CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.

4. Equivalences and Cross-References

Reference ETA055C02A2 is Cahnos’s own catalogue code (ETA series: reinforced oral tracheal tubes with cuff, without guide) and must not be confused with the official reference number of any specific manufacturer. To date, there is no manufacturer-validated equivalence table for this reference, so the following options are classified as comparable at category level (not interchangeable 1:1), pending technical verification against each manufacturer’s official datasheet:

Manufacturer / Line Reference Description Key difference
Endosid® (Asid Bonz) 849055 Spiral reinforced endotracheal tube with Murphy eye and cuff, ID 5.5 mm Comparable by category; verify inflation system, outer diameter and guide
P. J. Dahlhausen 44.000.20.055 Reinforced endotracheal tube with cuff (Woodbridge type), ID 5.5 mm, PVC, sterile Comparable by category; verify presence of Murphy eye and connector
P. J. Dahlhausen 44.000.10.055 Magill-type endotracheal tube with cuff and Murphy eye, ID 5.5 mm Comparable by category; differs in reinforcement (without helical armouring)
Teleflex (Rüsch® / Sheridan®), Medtronic (Shiley™), ICU Medical (Portex®), Intersurgical — Reinforced cuffed endotracheal tube lines on the market Comparable by category; not interchangeable 1:1 without verification of datasheet and IFU

Comparables within the Cahnos catalogue (same ID 5.5 mm size, not interchangeable 1:1):

Reference Description Key difference
ETA055002A2 Reinforced oral tube without cuff, with Murphy eye, ID 5.5 mm Without cuff
ETAM55C02A1 Reinforced oral tube with cuff, insertion guide and Murphy eye, ID 5.5 mm Adds included insertion stylet
ETAN55C02 Oral tube with cuff and Murphy eye, ID 5.5 mm Without helical reinforcement
ETAN55002 Oral tube without cuff and without reinforcement, with Murphy eye, ID 5.5 mm Without cuff or reinforcement

Fields to be checked before comparing: internal diameter (5.5 mm), material (medical-grade PVC), cuff type (high volume / low pressure), presence of Murphy eye, 15 mm connector and helical reinforcement. There is no manufacturer-validated equivalence table for this reference; consult the Cahnos technical department before using this reference as an equivalence in tenders or bids or as a direct replacement for stock from other brands.

5. Selection tips and variants of interest

Size selection: the 5.5 mm ID is intended for older paediatric patients, adolescents or adults with a reduced-calibre airway. As a general clinical practice guideline (not a manufacturer specification), the largest size compatible with the patient’s anatomy and the centre’s protocol is always selected; in this paediatric-adolescent range, the internal diameter directly affects flow and resistance to gas passage.

Cuff pressure: check the integrity of the cuff, pilot balloon and lumen patency before intubation; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual range in clinical practice) to minimise the risk of pressure injury to the tracheal mucosa, monitoring with a manometer if one is available.

Pre-intubation verification: check the pre-inflation of the cuff, patency of the Murphy eye, correct attachment of the 15 mm connector and integrity of the helical reinforcement along the tube body.

Variants of interest: if insertion assistance is required, consider Ref. ETAM55C02A1 (same size, with guide); if the procedure is short and the balloon is to be avoided, Ref. ETA055002A2 (reinforced without cuff). Complete the intubation cart stock with the adjacent sizes in the range (ETA045C02A2 and ETA065C02A2) and, in case of risk of ventilator-associated pneumonia (VAP) in prolonged intubations, consult the lines with subglottic suction lumen. Single-use product: do not re-sterilise or reuse. Contact the technical-commercial department of Cahnos for samples, volume conditions and approval of references for your tender.

Additional information

Material

Medical-grade polyvinyl chloride (PVC), transparent, latex-free

Access route

Oral (orotracheal)

Inner diameter

5.5 mm

Cuff type

Sealing (cuff inflation), with pilot balloon and self-sealing valve

Reinforcement

Helical anti-kink spiral integrated into the wall

Murphy eye

Yes, distal lateral safety opening

Connector

Universal 15 mm (ISO 5356-1)

Marking

Radiopaque contrast line and depth graduation

Sterilisation

Ethylene oxide (EO), sterile, individually packaged

Use

Single-use, non-reusable

Presentation

Box of 10 units

Indications

Positive pressure ventilation and anaesthesia administration when face mask is not viable

Indicative population

Older child, adolescent or adult with a reduced-calibre airway

Regulatory standard

ISO 5361 (tracheal tubes); connector ISO 5356-1; verify CE/MDR marking of each batch

Reviews