Reinforced Oral Endotracheal Tube with Cuff, Insertion Guide and Murphy Eye – ID 8.0 mm | Medical-Grade PVC, Single-Use | Ref. ETAM80C02A1 | Box of 10 units

118,95 €

Reinforced oral endotracheal tube with cuff, insertion guide and Murphy eye, ID 8.0 mm (Ref. ETAM80C02A1), manufactured in medical-grade polyvinyl chloride (PVC), transparent and latex-free. Its integrated helical spiral resists compression, biting and kinking, keeping the airway patent during positive-pressure ventilation, general anaesthesia and intensive care when a face mask is not viable. Includes insertion guide, sealing cuff with pilot balloon and self-sealing valve, universal 15 mm connector (ISO 5356-1) and radiopaque line for position control. Presentation in a box of 10 sterile units, individually packaged, for restocking intubation carts, ICU bays and operating theatres. Indicated in head and neck, ENT and maxillofacial surgeries where the tube is exposed to repositioning or risk of kinking.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETAM80C02A1

Description

1. Introduction

The reinforced oral endotracheal tube with cuff, insertion guide and Murphy eye of 8.0 mm (Ref. ETAM80C02A1) is the airway solution that anaesthesia, emergency and intensive care services need when face mask ventilation is not viable. Made of medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the strength of the anti-kink helical reinforcement with the airtight seal of the cuff and the safety of the Murphy eye, providing a patent and stable airway during critical procedures. It is supplied in a box of 10 individually packaged units, designed for the intubation cart and high-turnover hospital consumables, ensuring a uniform and reliable standard in every procedure.

2. Technical explanation of the equipment and procedure

In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, aided by the included insertion guide, passes through the glottis and sits in the trachea, below the vocal cords, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The guide provides controlled rigidity during advancement and is removed once the tube is placed.

The integrated helical reinforcement in the PVC wall prevents the tube from collapsing under external compression, biting or kinking, making it especially suitable for head and neck surgery, ENT, maxillofacial, thyroid, prone positioning and complex surgical positions. The sealing cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of secretions and stabilises the device during positive pressure ventilation. The Murphy eye, a distal lateral opening, acts as a safety route: if the tip of the tube rests against the tracheal or bronchial wall, respiratory flow continues through that opening and occlusion is never total. The universal 15 mm connector (ISO 5356-1), radiopaque line and depth graduation allow connection to the circuit and radiographic verification of position.

3. Technical Specifications

The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:

Parameter Specification
Reference (SKU) ETAM80C02A1 (distributor’s own code Cahnos; ETAM series: reinforced with cuff and guide)
Type Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced
Access route Oral (orotracheal)
Internal diameter (ID) 8.0 mm (standard adult size)
Reinforcement Anti-kink helical spiral integrated into the tube wall
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Intubation guide Included (insertion guide/stylet, removed after placement)
Sleeve Sealing, cuff inflation with pilot balloon and self-sealing valve
Murphy eye Present (distal lateral safety opening)
Tip Atraumatic, rounded and gently bevelled
Connector Universal 15 mm, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque contrast line and depth graduation
Sterilisation Ethylene oxide (EO/ETO), sterile, individually packaged
Use Single-use, non-reusable
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Presentation Box of 10 units
Indicative population Adult

Range of sizes available at Cahnos (ETAM family, reinforced with cuff, guide and Murphy eye):

Reference Internal diameter (ID) Indicative patient
ETAM30C02A1 3.0 mm Newborn
ETAM35C02A1 3.5 mm Newborn
ETAM45C02A1 4.5 mm Child
ETAM50C02A1 5.0 mm Child
ETAM55C02A1 5.5 mm Child / small adult
ETAM65C02A1 6.5 mm Small adult
ETAM70C02A1 7.0 mm Adult
ETAM75C02A1 7.5 mm Adult
ETAM80C02A1 (this product) 8.0 mm Adult
ETAM85C02A1 8.5 mm Adult / large adult
ETAM90C02A1 9.0 mm Large adult
ETAM95C02A1 9.5 mm Large adult

Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthesia equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; the universal connector complies with ISO 5356-1. Verify the declaration of conformity, CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.

4. Equivalences and Cross-References

The reference ETAM80C02A1 is a code of its own from the Cahnos range (ETAM series: reinforced oral tracheal tubes with cuff and guide). This family follows the technical nomenclature of the DEAFLUX line from DEAS S.r.l. (Italy), but should not be confused with the official part number of any specific manufacturer: it must be treated as the distributor’s internal reference and verified before use in tenders that require the manufacturer’s code.

Functional category equivalence (not interchangeable 1:1). By clinical indication (reinforced oral endotracheal tube with cuff and Murphy eye, ID 8.0 mm for adults) this product is comparable to armoured tubes from manufacturers such as Teleflex (Rüsch®), Medtronic (Shiley™ / Mallinckrodt™), ICU Medical (Portex® Blue Line®) and Intersurgical. All these brands offer oral tubes with helical reinforcement to resist compression, but they differ in outer diameter (OD), total length, distal tip geometry and cuff characteristics, so they must be compared sheet by sheet and IFU before replacing a specific product. The following market references are cited solely as a functional category comparison and their code must be verified against the manufacturer before any substitution:

Reference / Line Description Degree of correspondence
849080 / 849080-M (ENDOSID® / Asid Bonz) Reinforced spiral endotracheal tube with high-volume low-pressure cuff and Murphy eye, 8.0 mm; the -M variant includes an intubation stylet Comparable by category; verify inflation system, outer diameter and guide
44.000.09.080 (P. J. Dahlhausen) Magill-type endotracheal tube with cuff and guide, 8.0 mm Comparable by category; verify presence of spiral reinforcement and IFU
44.000.10.080 (P. J. Dahlhausen) Magill-type endotracheal tube with cuff and Murphy eye, 8.0 mm Comparable by category; without spiral reinforcement
118-80M (Safety-Flex, Mallinckrodt/Teleflex) Reinforced endotracheal tube with cuff and Murphy tip, 8.0 mm, 15 mm connector Comparable by category; pending verification of official data sheet
Rüsch® / Sheridan® (Teleflex), Shiley™ (Medtronic), Portex® (ICU Medical), Intersurgical Reinforced cuffed endotracheal tube lines on the market Comparable by category; not interchangeable 1:1 without verification of datasheet and IFU

Fields compared before comparing: internal diameter (8.0 mm), material (medical-grade PVC), cuff type (high volume / low pressure), presence of Murphy eye, insertion guide, 15 mm connector and helical reinforcement. There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using this reference as an equivalence in tenders or bids or as a direct replacement for stock from other brands. Comparables by category within the Cahnos catalogue in ID 8.0 mm (not interchangeable 1:1):

Reference Description Key difference
ETA080C02A2 Reinforced oral endotracheal tube with cuff and Murphy eye, ID 8.0 mm Without insertion guide
ETAN80C02 Oral endotracheal tube with cuff and Murphy eye, ID 8.0 mm Without helical reinforcement
ETSL80C02 Oral endotracheal tube with cuff and subglottic suction lumen, ID 8.0 mm Adds subglottic suction (DEAFLUX line)
ETPN80C02 Preformed nasal tracheal tube with cuff and Murphy eye, ID 8.0 mm Preformed nasal approach

5. Selection tips and variants of interest

Size selection (usual clinical practice, not manufacturer specification): the ID of 8.0 mm is one of the most demanded sizes in adult intubation. As a general reference, tubes from 7.0 to 9.0 mm are used depending on build (7.0–7.5 mm in women and 7.5–8.5 mm in men), always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.

Cuff pressure: check the integrity of the cuff, the pilot balloon and the patency of the lumen before intubation; inflate with a syringe and maintain the sealing pressure within the usual clinical range (indicative 20–30 cmH₂O; usual market practice, confirm with the service protocol), monitoring with a manometer to minimise damage to the tracheal mucosa during prolonged ventilation.

Prior verification: check the correct fixation and removal of the guide after placement, the patency of the Murphy eye and the anchoring of the 15 mm connector to the circuit. Single-use product: do not re-sterilise or reuse.

Variants of interest: if you do not need a guide, consider Ref. ETA080C02A2 (reinforced with cuff, same size); if intubation will be prolonged and there is a risk of ventilator-associated pneumonia (VAP), consider the series with subglottic suction lumen (ETSL80C02); for nasal approaches, the preformed ETPN80C02. Complete the intubation cart stock with the adjacent sizes of the ETAM family (ETAM75C02A1 and ETAM85C02A1) and consult the technical-commercial department of Cahnos for volume conditions, samples and hospital supply lead times.

Additional information

Reference

ETAM80C02A1 (distributor's own code Cahnos)

Product type

Reinforced oral endotracheal tube with cuff, guide and Murphy eye

Access route

Oral (orotracheal)

Inner diameter

8.0 mm

Material

Medical-grade polyvinyl chloride (PVC), latex-free

Reinforcement

Anti-kink helical spiral

Intubation guide

Included

Sleeve

Yes, cuff inflation with pilot balloon and self-sealing valve

Murphy eye

Present

Connector

Universal 15 mm (ISO 5356-1)

Marking

Radiopaque line and depth graduation

Sterilisation

Ethylene oxide (EO), individual sterile packaging

Use

Single-use, non-reusable

Presentation

Box of 10 units

Regulatory standard

ISO 5361; connector ISO 5356-1; verify CE/MDR marking of each batch

Radiopacity

Radiopaque contrast line and depth graduation

Indications

Positive pressure ventilation and anaesthesia administration

Tipo paciente

Adult