Description
1. Introduction
The reinforced oral endotracheal tube with cuff, insertion guide and Murphy eye of 8.0 mm (Ref. ETAM80C02A1) is the airway solution that anaesthesia, emergency and intensive care services need when face mask ventilation is not viable. Made of medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the strength of the anti-kink helical reinforcement with the airtight seal of the cuff and the safety of the Murphy eye, providing a patent and stable airway during critical procedures. It is supplied in a box of 10 individually packaged units, designed for the intubation cart and high-turnover hospital consumables, ensuring a uniform and reliable standard in every procedure.
2. Technical explanation of the equipment and procedure
In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, aided by the included insertion guide, passes through the glottis and sits in the trachea, below the vocal cords, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The guide provides controlled rigidity during advancement and is removed once the tube is placed.
The integrated helical reinforcement in the PVC wall prevents the tube from collapsing under external compression, biting or kinking, making it especially suitable for head and neck surgery, ENT, maxillofacial, thyroid, prone positioning and complex surgical positions. The sealing cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of secretions and stabilises the device during positive pressure ventilation. The Murphy eye, a distal lateral opening, acts as a safety route: if the tip of the tube rests against the tracheal or bronchial wall, respiratory flow continues through that opening and occlusion is never total. The universal 15 mm connector (ISO 5356-1), radiopaque line and depth graduation allow connection to the circuit and radiographic verification of position.
3. Technical Specifications
The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:
| Parameter | Specification |
| Reference (SKU) | ETAM80C02A1 (distributor’s own code Cahnos; ETAM series: reinforced with cuff and guide) |
| Type | Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 8.0 mm (standard adult size) |
| Reinforcement | Anti-kink helical spiral integrated into the tube wall |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Intubation guide | Included (insertion guide/stylet, removed after placement) |
| Sleeve | Sealing, cuff inflation with pilot balloon and self-sealing valve |
| Murphy eye | Present (distal lateral safety opening) |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth graduation |
| Sterilisation | Ethylene oxide (EO/ETO), sterile, individually packaged |
| Use | Single-use, non-reusable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
| Indicative population | Adult |
Range of sizes available at Cahnos (ETAM family, reinforced with cuff, guide and Murphy eye):
| Reference | Internal diameter (ID) | Indicative patient |
| ETAM30C02A1 | 3.0 mm | Newborn |
| ETAM35C02A1 | 3.5 mm | Newborn |
| ETAM45C02A1 | 4.5 mm | Child |
| ETAM50C02A1 | 5.0 mm | Child |
| ETAM55C02A1 | 5.5 mm | Child / small adult |
| ETAM65C02A1 | 6.5 mm | Small adult |
| ETAM70C02A1 | 7.0 mm | Adult |
| ETAM75C02A1 | 7.5 mm | Adult |
| ETAM80C02A1 (this product) | 8.0 mm | Adult |
| ETAM85C02A1 | 8.5 mm | Adult / large adult |
| ETAM90C02A1 | 9.0 mm | Large adult |
| ETAM95C02A1 | 9.5 mm | Large adult |
Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthesia equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; the universal connector complies with ISO 5356-1. Verify the declaration of conformity, CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.
4. Equivalences and Cross-References
The reference ETAM80C02A1 is a code of its own from the Cahnos range (ETAM series: reinforced oral tracheal tubes with cuff and guide). This family follows the technical nomenclature of the DEAFLUX line from DEAS S.r.l. (Italy), but should not be confused with the official part number of any specific manufacturer: it must be treated as the distributor’s internal reference and verified before use in tenders that require the manufacturer’s code.
Functional category equivalence (not interchangeable 1:1). By clinical indication (reinforced oral endotracheal tube with cuff and Murphy eye, ID 8.0 mm for adults) this product is comparable to armoured tubes from manufacturers such as Teleflex (Rüsch®), Medtronic (Shiley™ / Mallinckrodt™), ICU Medical (Portex® Blue Line®) and Intersurgical. All these brands offer oral tubes with helical reinforcement to resist compression, but they differ in outer diameter (OD), total length, distal tip geometry and cuff characteristics, so they must be compared sheet by sheet and IFU before replacing a specific product. The following market references are cited solely as a functional category comparison and their code must be verified against the manufacturer before any substitution:
| Reference / Line | Description | Degree of correspondence |
| 849080 / 849080-M (ENDOSID® / Asid Bonz) | Reinforced spiral endotracheal tube with high-volume low-pressure cuff and Murphy eye, 8.0 mm; the -M variant includes an intubation stylet | Comparable by category; verify inflation system, outer diameter and guide |
| 44.000.09.080 (P. J. Dahlhausen) | Magill-type endotracheal tube with cuff and guide, 8.0 mm | Comparable by category; verify presence of spiral reinforcement and IFU |
| 44.000.10.080 (P. J. Dahlhausen) | Magill-type endotracheal tube with cuff and Murphy eye, 8.0 mm | Comparable by category; without spiral reinforcement |
| 118-80M (Safety-Flex, Mallinckrodt/Teleflex) | Reinforced endotracheal tube with cuff and Murphy tip, 8.0 mm, 15 mm connector | Comparable by category; pending verification of official data sheet |
| Rüsch® / Sheridan® (Teleflex), Shiley™ (Medtronic), Portex® (ICU Medical), Intersurgical | Reinforced cuffed endotracheal tube lines on the market | Comparable by category; not interchangeable 1:1 without verification of datasheet and IFU |
Fields compared before comparing: internal diameter (8.0 mm), material (medical-grade PVC), cuff type (high volume / low pressure), presence of Murphy eye, insertion guide, 15 mm connector and helical reinforcement. There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using this reference as an equivalence in tenders or bids or as a direct replacement for stock from other brands. Comparables by category within the Cahnos catalogue in ID 8.0 mm (not interchangeable 1:1):
| Reference | Description | Key difference |
| ETA080C02A2 | Reinforced oral endotracheal tube with cuff and Murphy eye, ID 8.0 mm | Without insertion guide |
| ETAN80C02 | Oral endotracheal tube with cuff and Murphy eye, ID 8.0 mm | Without helical reinforcement |
| ETSL80C02 | Oral endotracheal tube with cuff and subglottic suction lumen, ID 8.0 mm | Adds subglottic suction (DEAFLUX line) |
| ETPN80C02 | Preformed nasal tracheal tube with cuff and Murphy eye, ID 8.0 mm | Preformed nasal approach |
5. Selection tips and variants of interest
Size selection (usual clinical practice, not manufacturer specification): the ID of 8.0 mm is one of the most demanded sizes in adult intubation. As a general reference, tubes from 7.0 to 9.0 mm are used depending on build (7.0–7.5 mm in women and 7.5–8.5 mm in men), always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.
Cuff pressure: check the integrity of the cuff, the pilot balloon and the patency of the lumen before intubation; inflate with a syringe and maintain the sealing pressure within the usual clinical range (indicative 20–30 cmH₂O; usual market practice, confirm with the service protocol), monitoring with a manometer to minimise damage to the tracheal mucosa during prolonged ventilation.
Prior verification: check the correct fixation and removal of the guide after placement, the patency of the Murphy eye and the anchoring of the 15 mm connector to the circuit. Single-use product: do not re-sterilise or reuse.
Variants of interest: if you do not need a guide, consider Ref. ETA080C02A2 (reinforced with cuff, same size); if intubation will be prolonged and there is a risk of ventilator-associated pneumonia (VAP), consider the series with subglottic suction lumen (ETSL80C02); for nasal approaches, the preformed ETPN80C02. Complete the intubation cart stock with the adjacent sizes of the ETAM family (ETAM75C02A1 and ETAM85C02A1) and consult the technical-commercial department of Cahnos for volume conditions, samples and hospital supply lead times.