Description
1. Introduction
The reinforced oral endotracheal tube with cuff, stylet and Murphy eye of 9.0 mm (ref. ETAM90C02A1) is a single-use device designed to ensure a patent and stable airway in critical situations: positive pressure ventilation, administration of general anaesthesia and management of the patient in intensive care when face mask ventilation is not possible.
Its helical reinforcement armour makes it the reference option when tube movement, special positioning, head and neck surgery or risk of kinking are anticipated. It is supplied in a box of 10 units, ready for restocking intubation trolleys, ICU bays and operating theatres, ensuring a uniform and reliable standard in every airway procedure.
2. Technical explanation of the equipment and procedure
Orotracheal intubation involves introducing the tube orally, through the glottis, until its distal end is positioned in the trachea, below the vocal cords. The included insertion stylet facilitates placement and correct positioning, providing controlled rigidity during advancement and allowing its removal once the tube is placed.
The body reinforced with an integrated helical spiral in the PVC wall prevents collapse of the tube under external compression, biting or kinking, maintaining airway patency in complex positions. The high-volume, low-pressure cuff, inflated via the pilot balloon, seals the tracheal lumen and allows positive pressure ventilation without leaks, as well as preventing aspiration of pharyngeal secretions. The Murphy eye, a distal lateral orifice, acts as a safety pathway: if the tip rests against the tracheal or bronchial wall, respiratory flow continues through this orifice, avoiding total occlusion.
3. Technical Specifications
| Reference | ETAM90C02A1 |
| Type | Reinforced oral endotracheal tube with cuff |
| Internal diameter (ID) | 9.0 mm |
| Access route | Oral (orotracheal) |
| Material | Medical-grade polyvinyl chloride (PVC), transparent |
| Reinforcement | Integrated helical spiral, kink resistance |
| Insertion guide | Yes, included |
| Sleeve | High volume and low pressure, with pilot balloon and valve |
| Murphy eye | Present (distal lateral safety opening) |
| Connector | Universal 15 mm (ISO 5356-1) |
| Radiopacity | X-ray contrast line |
| Latex | Natural rubber latex-free |
| Sterility | Sterile, individually packaged (ethylene oxide) |
| Use | Single-use, non-reusable |
| Indications | Positive pressure ventilation and anaesthesia administration |
| Presentation | Box of 10 units |
| Indicative population | Large adult |
Range of sizes available from Cahnos (ETAM family, reinforced with cuff and guide):
| Reference | Internal diameter (ID) | Indicative patient |
| ETAM30C02A1 | 3.0 mm | Newborn |
| ETAM35C02A1 | 3.5 mm | Newborn |
| ETAM45C02A1 | 4.5 mm | Child |
| ETAM50C02A1 | 5.0 mm | Child |
| ETAM55C02A1 | 5.5 mm | Child / small adult |
| ETAM65C02A1 | 6.5 mm | Small adult |
| ETAM70C02A1 | 7.0 mm | Adult |
| ETAM75C02A1 | 7.5 mm | Adult |
| ETAM80C02A1 | 8.0 mm | Adult |
| ETAM85C02A1 | 8.5 mm | Adult / large adult |
| ETAM90C02A1 (this product) | 9.0 mm | Large adult |
| ETAM95C02A1 | 9.5 mm | Large adult |
4. Equivalences and Cross-References
Functional category equivalence (not interchangeable 1:1). By clinical indication (reinforced oral endotracheal tube with cuff, stylet and Murphy eye, ID 9.0 mm) this product is comparable to armoured tubes from manufacturers such as Teleflex (Rüsch®), Medtronic (Shiley™ / Mallinckrodt™) and ICU Medical (Portex® Blue Line®). All these brands offer oral tubes with helical reinforcement to resist compression, but they differ in outer diameter, total length, distal tip geometry and cuff characteristics, so they must be compared specification by specification before replacing a specific product.
The reference ETAM90C02A1 is a proprietary code of the Cahnos range; it does not correspond to an official manufacturer part number published in public sources, so it should be treated as an internal distributor reference. There is no manufacturer-validated equivalence table for this reference; consult the technical department of Cahnos before using it in tenders or as a replacement for stock from other brands. Fields verified before comparing: internal diameter (9.0 mm), material (PVC), cuff type (high volume/low pressure), presence of Murphy eye, 15 mm connector and helical reinforcement.
| Reference | Description | Key difference |
| ETAM90C02A1 (Cahnos) | Reinforced oral endotracheal tube with cuff, stylet and Murphy eye, ID 9.0 mm | Reference product |
| ETAM95C02A1 (Cahnos) | Same reinforced family with stylet, ID 9.5 mm | Larger size in the same range |
| ETAM85C02A1 (Cahnos) | Same reinforced family with stylet, ID 8.5 mm | Smaller size in the same range |
| ETA090C02A2 (Cahnos) | Reinforced oral tube with cuff and Murphy eye ID 9.0 mm, without stylet | Without insertion guide |
| ETAN90C02 (Cahnos) | Oral tube with cuff and Murphy eye ID 9.0 mm, without reinforcement | Without helical reinforcement |
| ETSL90C02 (Cahnos) | Oral tube with cuff and subglottic suction lumen ID 9.0 mm | Adds subglottic suction |
| ETPO90C02 (Cahnos) | Preformed oral tube (RAE) with cuff ID 9.0 mm | Preformed curve for head and neck |
| Teleflex Rüsch® / Medtronic Shiley™ / ICU Medical Portex® | Reinforced endotracheal tube lines on the market | Comparable by category; verify data sheet and IFU before replacing |
5. Selection tips and variants of interest
The ID 9.0 mm is reserved for large adult patients; as a general guideline, in adults tubes of 7.0 to 9.0 mm are used depending on build and airway, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.
Before insertion, verify the integrity of the cuff and pilot balloon and check the sealing pressure with a manometer, keeping it within the usual clinical range (indicative 20–30 cmH₂O; usual practice on the market, confirm the service protocol). The reinforced tube with stylet is especially indicated when frequent repositioning, prone positioning, head and neck surgery or risk of kinking are anticipated.
If intubation is to be prolonged and there is a risk of ventilator-associated pneumonia (VAP), consider the range with subglottic suction lumen (ETSL series). For procedures where a stylet is not required, select the standard reinforced tube from the ETA series; for nasal approaches or oral and maxillofacial surgery, consider the preformed tubes (ETPO series). Complete the intubation trolley stock with the adjacent sizes of the range (ETAM85C02A1, ETAM95C02A1) and consult your technical-commercial representative at Cahnos for volume conditions and hospital supply lead times.





Reviews