Description
1. Introduction
The Reinforced Oral Endotracheal Tube with Cuff, Stylet and Murphy Eye, ID 4.0 mm (Ref. ETAM40C02A1), is the airway solution that anaesthesia, emergency and intensive care departments need when face mask ventilation is not possible. Made from medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the strength of the helical reinforcement with the airtight seal of the cuff and the safety of the Murphy eye, providing a patent and stable airway during critical procedures. It is supplied in a box of 10 units, individually packaged, ideal for the intubation trolley and high-turnover hospital consumables.
2. Technical explanation of the equipment and procedure
In orotracheal intubation, the tube is inserted through the mouth under laryngoscopic vision with the aid of the included intubation stylet, passes through the glottis and is placed in the trachea, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The spiral helical reinforcement embedded in the tube wall prevents kinking and collapse during flexion, head and neck movements or external compression, making it particularly suitable for ENT, maxillofacial, thyroid surgery or complex surgical positions. The cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of gastric or pharyngeal contents and stabilises the device during positive pressure ventilation. The Murphy eye, a distal lateral opening, acts as an alternative ventilation pathway: if the tip of the tube becomes obstructed by secretions or rests against the tracheal wall, respiratory flow continues through this opening and occlusion is never complete. The radiopaque line and depth graduations allow radiographic verification of the correct tube position. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.
3. Technical Specifications
The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:
| Parameter | Specification |
|---|---|
| Reference (SKU) | ETAM40C02A1 (Cahnos distributor’s own code) |
| Type | Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 4.0 mm |
| Reinforcement | Helical spiral anti-kink reinforcement in the tube wall |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Sleeve | Yes, cuff inflation with pilot balloon and self-sealing valve |
| Intubation guide | Included (insertion stylet/guide) |
| Murphy eye | Present, distal lateral safety orifice |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth graduation |
| Sterilisation | Ethylene oxide (EO), sterile, individually packaged |
| Use | Single-use, disposable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
Confirmed variants of the same size in the Cahnos catalogue:
| Reference | Description | Key difference |
|---|---|---|
| ETAM40C02A1 | This product: oral reinforced with cuff, stylet and Murphy eye, ID 4.0 mm | Includes intubation stylet |
| ETA040C02A2 | Oral reinforced with cuff and Murphy eye, ID 4.0 mm | Without intubation stylet |
| ETAN40C02 | Oral with cuff and Murphy eye, ID 4.0 mm | Without helical reinforcement |
| ETA040002A2 | Oral reinforced without cuff, with Murphy eye, ID 4.0 mm | Without cuff |
| ETAN40002 | Oral without cuff, with Murphy eye, ID 4.0 mm | Without cuff or reinforcement |
| ETAM45C02A1 | Oral reinforced with cuff, stylet and Murphy eye, ID 4.5 mm | Larger size in the ETAM series |
Applicable reference standard: ISO 5361 (respiratory and anaesthesia equipment: tracheal tubes and connectors); universal connector conforming to ISO 5356-1. Verify the declaration of conformity, CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.
4. Equivalences and Cross-References
The SKU ETAM40C02A1 is Cahnos’s own code (ETAM series: reinforced oral tracheal tubes with cuff and stylet). This family follows the technical nomenclature of the DEAFLUX line from DEAS S.r.l. (Italy), but should not be confused with the official reference number of any specific manufacturer. To date, there is no manufacturer-validated equivalence table for this reference, so we classify the following options as comparable at category level (not interchangeable 1:1), pending technical verification against each manufacturer’s official datasheet:
| Reference | Description | Degree of correspondence |
|---|---|---|
| 841040 (Endosid, Cahnos catalogue) | Tube with low-pressure cuff and Murphy eye, ID 4.0 mm | Confirmed comparable in own catalogue; differ in manufacturer of origin and inflation system |
| ETA040C02A2 (Cahnos) | Oral reinforced with cuff and Murphy eye, ID 4.0 mm | Comparable by category; differs in the intubation stylet |
| PB-212040U (ISSO, PRO-BREATHE) | Tracheal tube with cuff, ID 4.0 mm | Comparable by category; pending verification of official data sheet |
| 44.000.10.040 / 44.000.11.040 (P. J. Dahlhausen) | Magill tracheal tubes with cuff, ID 4.0 mm | Comparable by category; exact code confirmation pending |
| Rüsch® / Sheridan (Teleflex), Shiley™ (Medtronic), Portex® (ICU Medical), Intersurgical | Market lines of reinforced cuffed tubes | Comparable by category; not interchangeable 1:1 without datasheet verification |
There is no manufacturer-validated equivalence table for this reference; consult the Cahnos technical department before using this reference as an equivalence in tenders or bids or as a direct substitute for another brand.
5. Selection tips and variants of interest
Size selection (usual practice in clinical use, not manufacturer specification): the 4.0 mm ID is intended for paediatric patients (infants and young children; general guidance of 3.5 to 5.0 mm in this range) and for patients with a reduced airway size; the final choice should be based on each patient’s age, weight and anaesthetic assessment, as well as on the department’s protocol.
Cuff pressure: check the integrity of the cuff, the pilot balloon and the patency of the lumen before intubation; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise the risk of pressure injury to the tracheal mucosa, monitoring with a manometer if the department has one.
Prior verification: check the correct fixation and removal of the stylet after placement, the patency of the Murphy eye and the anchoring of the 15 mm connector to the circuit.
Variants of interest: if you do not require a guide, consider Ref. ETA040C02A2 (reinforced with cuff, same size); for a leak-proof seal without reinforcement, Ref. ETAN40C02; for reduced-size airways without cuff, Ref. ETA040002A2; and if you need a 4.5 mm size, Ref. ETAM45C02A1 from the same family. Complement with water-soluble lubricant and an introducer or intubation stylet, available at Cahnos, to fully equip the intubation cart. Contact the technical-commercial department at Cahnos for samples, volume pricing and the approval of references for your tender.





Reviews
There are no reviews yet.