We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Oral Endotracheal Tube (Orotracheal) with Cuff and Murphy Eye – ID 4.5 mm | Medical-Grade PVC, Single-Use, Box of 10 Units (Ref. ETAN45C02)

16,05 €

Oral endotracheal tube (orotracheal) with cuff and Murphy eye with a 4.5 mm internal diameter, manufactured from medical-grade polyvinyl chloride (PVC), sterile and single-use. Indicated for positive-pressure ventilation and administration of anaesthesia when a face mask is not feasible. It incorporates a sealing cuff with pilot balloon and self-sealing valve, universal 15 mm connector (ISO 5356-1), radiopaque line and depth scale for radiographic position control. Presentation in a box of 10 units, ideal for operating theatre, emergency, paediatrics and intensive care. Reference ETAN45C02.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETAN45C02

Description

1. Introduction

The Oral Endotracheal Tube with Cuff and Murphy Eye, 4.5 mm (Ref. ETAN45C02), is a single-use airway management device designed for orotracheal intubation of paediatric patients and patients with a reduced-calibre airway in the operating theatre, intensive care units, emergency departments and resuscitation. Made of medical-grade polyvinyl chloride (PVC), it ensures an effective seal and a patent, safe airway during mechanical ventilation and administration of anaesthesia. It is supplied in a box of 10 units, a cost-effective solution always available for the intubation trolley and hospital consumables.

2. Technical explanation of the device and procedure

In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and sits in the trachea, conducting gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. The cuff, inflated via the pilot balloon with a self-sealing valve, seals the tracheal lumen, prevents gas leaks, prevents aspiration of gastric or pharyngeal contents and stabilises the device during positive pressure ventilation. The Murphy eye, a distal lateral opening, acts as a safety route: if the tip of the tube becomes obstructed by secretions or rests against the tracheal wall, respiratory flow continues through this opening and occlusion is never complete. The radiopaque line and depth graduation marks allow the correct position of the tube to be verified radiographically. It is a single-use device: after each patient it must be discarded to avoid the risk of cross-infection.

3. Technical Specifications

Main features of the Oral Endotracheal Tube with Cuff and Murphy Eye ID 4.5 mm:

Parameter Specification
Reference (SKU) ETAN45C02
Type Oral endotracheal tube (orotracheal), Magill-type curve, with cuff and Murphy eye
Access route Oral (orotracheal)
Internal diameter (ID) 4.5 mm
Material Medical-grade polyvinyl chloride (PVC), transparent, flexible and durable
Latex Natural latex-free
Sleeve Yes, inflatable, with pilot balloon and self-sealing valve
Murphy eye Yes, distal lateral safety opening
Tip Atraumatic, rounded and gently bevelled
Connector Universal 15 mm (ISO 5356-1), compatible with ISO circuits
Marking Radiopaque contrast line and depth graduation
Sterilisation Ethylene oxide (EO), sterile, individually packaged
Use Single-use, disposable
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Presentation Box of 10 units

ETAN range: orotracheal tubes with cuff and Murphy eye (same configuration and presentation in boxes of 10 units):

Inner diameter Reference (box of 10 units)
2.5 mm ETAN25C02
3.0 mm ETAN30C02
3.5 mm ETAN35C02
4.0 mm ETAN40C02
4.5 mm ETAN45C02 (this product)
5.0 mm ETAN50C02
5.5 mm ETAN55C02
6.0 mm ETAN60C02
6.5 mm ETAN65C02
7.0 mm ETAN70C02
7.5 mm ETAN75C02
8.0 mm ETAN80C02
8.5 mm ETAN85C02
9.0 mm ETAN90C02
9.5 mm ETAN95C02
10.0 mm ETAN10C02

Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE/MDR marking on each supplied batch.

4. Equivalences and Cross-References

The SKU ETAN45C02 is Cahnos’s own code, associated with the nomenclature of the DEAFLUX line (DEAS S.r.l., Italy) of Magill tracheal tubes with cuff; it must not be confused with the official part number of any specific manufacturer. As of today, there is no equivalence table validated by the manufacturer for this reference; therefore we classify the following options according to their degree of correspondence:

  • Comparable by category, confirmed in Cahnos’s own catalogue (same configuration, 4.5 mm calibre, with cuff and Murphy eye): ENDOSID tube with low-pressure cuff and Murphy eye Ref. 841045, which shares indication, calibre and general geometry with the inflation cuff; it may differ in brand and inflation system. Not interchangeable 1:1 without verification of the data sheet.
  • Comparable at category level (same 4.5 mm calibre, not interchangeable 1:1): PRO-BREATHE tube from ISSO Ref. PB-212045U and Magill tracheal tubes with cuff from series 44.000.10.045 / 44.000.11.045 (P. J. Dahlhausen). They may differ in PVC compound, total length, cuff inflation pressure and bevel design.
  • Complementary references of the same 4.5 mm calibre in Cahnos’s catalogue: ENDOSID Magill Ref. 840045 (without cuff), Ref. 842045 (without cuff and without Murphy eye), Ref. 843045 (without cuff with Murphy eye), oral tube without cuff Ref. ETAN45002, reinforced Ref. ETA045C02A2 and reinforced with guide Ref. ETAM45C02A1.
Reference Description Key difference
841045 ENDOSID tube with low-pressure cuff and Murphy eye ID 4.5 mm Same configuration; verify inflation system and outer diameter (OD)
ETAN45002 Oral tube without cuff with Murphy eye ID 4.5 mm Without sealing cuff: not suitable for prolonged airtight sealing
ETA045C02A2 Reinforced oral tube with cuff and Murphy eye ID 4.5 mm Adds helical anti-kink reinforcement
ETAM45C02A1 Reinforced oral tube with cuff, guide and Murphy eye ID 4.5 mm Incorporates intubation guide

There is no equivalence table validated by the manufacturer for this reference; consult Cahnos’s technical department before using this reference as an equivalence in tender documents or bids.

5. Selection tips and variants of interest

  • Patient selection (usual use in clinical practice, not manufacturer specification): the ID 4.5 mm calibre is used in infants and young children (general guidance: 3.5–5.0 mm in this range), as well as in patients with a reduced-calibre airway; the final choice must be based on the age, weight and anaesthetic assessment of each patient.
  • Cuff pressure: check the integrity of the cuff, the pilot balloon and the patency of the lumen before intubation; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise the risk of pressure injury to the tracheal mucosa, monitoring with a manometer if the department has one.
  • Prior verification: check the correct inflation of the cuff, the patency of the Murphy eye and the secure attachment of the 15 mm connector.
  • Variants of interest: the ETAN series covers from 2.5 mm to 10.0 mm in the same configuration; if there is a risk of kinking or frequent repositioning, consider the reinforced tubes (ETA045C02A2); for prolonged ventilation with subglottic drainage, the ETSL series; and for oral or maxillofacial surgery, the RAE-type preformed tubes. Consult our technical sales team at Cahnos for the approval of references and the configuration of the size stock best suited to your department.

Additional information

Product type

Oral endotracheal tube (orotracheal), Magill-type curve, with cuff and Murphy eye

Access route

Oral (orotracheal)

Inner diameter

4.5 mm

Material

Medical-grade polyvinyl chloride (PVC)

Latex

Natural latex-free

Sleeve

Yes, inflatable, with pilot balloon and self-sealing valve

Murphy eye

Yes, distal lateral safety opening

Tip

Atraumatic, rounded and gently bevelled

Connector

Universal 15 mm (ISO 5356-1)

Marking

Radiopaque contrast line and depth graduation

Sterilisation

Ethylene oxide (EO), sterile, individually packaged

Use

Single-use, disposable

Presentation

Box of 10 units

Regulatory standard

ISO 5361 / ISO 5356-1

Indications

Positive pressure ventilation and anaesthesia administration when face mask is not viable

Reviews

There are no reviews yet.

Be the first to review “Oral Endotracheal Tube (Orotracheal) with Cuff and Murphy Eye – ID 4.5 mm | Medical-Grade PVC, Single-Use, Box of 10 Units (Ref. ETAN45C02)”

Your email address will not be published. Required fields are marked *