Description
1. Introduction
The oral endotracheal tube with cuff and Murphy eye ID 8.0 mm (Ref. ETAN80C02) is a single-use airway management consumable, designed for orotracheal intubation of adult patients in intensive care units, operating theatres, emergency departments and anaesthesia services. Its construction in medical-grade polyvinyl chloride (PVC), latex-free, combines the rigidity required for guided placement with sufficient flexibility to adapt to the patient’s anatomy. Supplied in a box of 10 units, it is an excellent value-for-money option for restocking the intubation trolley and operating theatre consumables.
2. Technical explanation of the device
Orotracheal intubation involves introducing the tube orally through the glottis into the trachea, placing its distal end below the vocal cords. Once placed, the proximal end is connected to the ventilator, anaesthesia circuit or resuscitation bag via the universal 15 mm connector conforming to ISO 5356-1. The sealing cuff, inflated through the pilot balloon with a syringe or pressure gauge, seals the tracheal lumen: it prevents gas leaks during positive-pressure ventilation, prevents aspiration of secretions and stabilises the tube during prolonged mechanical ventilation. The Murphy eye, a lateral opening located near the distal end, acts as a safety route: if the tube tip were to rest against the tracheal or bronchial wall, respiratory flow would continue through this opening, preventing complete airway occlusion. The transparent material allows patency to be checked by condensation of respiratory flow, and the longitudinal radiopaque line facilitates position verification by radiographic control.
3. Technical Specifications
| Reference | ETAN80C02 (distributor SKU Cahnos) |
| Type | Oral (orotracheal), Magill type, with cuff and Murphy eye |
| Internal diameter (ID) | 8.0 mm (standard adult size) |
| Material | Medical-grade polyvinyl chloride (PVC), latex-free |
| Sleeve | Yes, inflatable with pilot balloon (high volume and low pressure) |
| Murphy eye | Present, distal lateral safety orifice |
| Connector | Universal 15 mm (ISO 5356-1) |
| Marking | Radiopaque line and depth marks |
| Use | Single-use (disposable), not reusable |
| Sterilisation | Ethylene oxide (ETO) per the DEAS/DEAFLUX range pattern; verify series labelling |
| Indication | Positive pressure ventilation and anaesthesia administration |
| Presentation | Box of 10 units |
Range of sizes in the ETAN family (oral tubes with cuff and Murphy eye, catalogue Cahnos):
| Reference | Internal diameter (ID) |
| ETAN25C02 | 2.5 mm |
| ETAN30C02 | 3.0 mm |
| ETAN35C02 | 3.5 mm |
| ETAN45C02 | 4.5 mm |
| ETAN55C02 | 5.5 mm |
| ETAN65C02 | 6.5 mm |
| ETAN75C02 | 7.5 mm |
| ETAN80C02 (this product) | 8.0 mm |
| ETAN85C02 | 8.5 mm |
| ETAN10C02 | 10.0 mm |
Dimension note: to compare outer diameter (OD) and total length, the reference line from the same manufacturer (ETSL range from DEAS S.r.l. with subglottic suction lumen) presents, for ID 8.0 mm, an OD of 12.2 mm, length of 330 mm and inflated cuff diameter of 26 mm. These dimensions correspond to that specific line and must be checked specification by specification before replacing the product.
4. Equivalences and Cross-References
Reference clarification: the code ETAN80C02 is the distributor’s own SKU (Cahnos) and corresponds to the nomenclature of the Magill-type oral tracheal tube family with cuff and Murphy eye from the DEAFLUX range of DEAS S.r.l. (Italy). It should not be confused with other lines from the same manufacturer: tubes with subglottic suction lumen (ETSL range), preformed oral or nasal tubes (ETPO/ETPN) or reinforced tubes (ETA/ETAM).
Functional category equivalence (not interchangeable 1:1). By clinical indication (endotracheal tube with cuff and Murphy eye, ID 8.0 mm for adults), it is comparable to reference 841080 from Endosid (8 mm with balloon and Murphy eye, also in the Cahnos catalogue) and, at category level, to Magill tubes with cuff from manufacturers such as Medtronic (Shiley™), Teleflex (Rüsch®) or ICU Medical (Portex). All share the same indication —tracheal sealing for positive-pressure ventilation—, but differ in outer diameter (OD), total length, geometry and cuff design, so they should not be treated as direct equivalents without specification-by-specification verification.
There is no reference equivalence table validated by the manufacturer for this code; consult the technical department of Cahnos before using in tendering or stock replacement.
5. Selection tips and variants of interest
- ID 8.0 mm is one of the most demanded sizes in adult intubation; as a general reference, tubes of 7.0–8.5 mm are used depending on build (7.0–7.5 mm in women and 7.5–8.5 mm in men), always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.
- After cuff inflation, maintain the sealing pressure within the usual clinical range (ideally 20–30 cmH2O, check the centre’s protocol) to minimise damage to the tracheal mucosa during prolonged ventilation.
- Before intubation, check the integrity of the cuff and pilot balloon and, after placement, verify the position using the radiopaque line and depth marks. Single-use product: do not re-sterilise or reuse.
- Variants of interest in the Cahnos catalogue: ETSL80C02 (same calibre with subglottic suction lumen, for prevention of ventilator-associated pneumonia in prolonged intubations), ETA080C02A2 (reinforced with cuff, greater resistance to kinking), ETAM80C02A1 (reinforced with cuff and guide) and ETPN80C02 (preformed nasal RAE for head and neck surgery). For adjacent sizes, the ETAN family is available from 2.5 to 10.0 mm.
- Recommended accessories: Luer syringe or pressure gauge for balloon inflation, tube fixation device and water-soluble lubricant for insertion.