Oral Endotracheal Tube with Cuff and Murphy Eye ID 7.0 mm | Medical-Grade PVC, Single-Use, Box of 10 units (Ref. ETAN70C02)

16,05 €

Oral endotracheal tube with cuff and Murphy eye of 7.0 mm internal diameter, manufactured in medical-grade polyvinyl chloride (PVC), transparent and latex-free. Designed for orotracheal intubation of adult patients, it allows positive-pressure ventilation and administration of anaesthesia when the use of a face mask is not feasible. It incorporates an inflatable cuff with pilot balloon, Murphy eye as a safety ventilation pathway, universal 15 mm connector (ISO 5356-1) and radiopaque line for position verification. Sterile single-use device, presented in a box of 10 units, ideal for operating theatre, ICU, emergency and resuscitation. Reference ETAN70C02, available immediately for your institution.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETAN70C02

Description

1. Introduction

The oral endotracheal tube with cuff and Murphy eye of 7.0 mm (ref. ETAN70C02) is a single-use airway device designed for orotracheal intubation of adult patients in anaesthesia, intensive care, emergency and resuscitation. Made of medical-grade PVC, latex-free, it combines a low-pressure sealing cuff with the characteristic lateral Murphy eye, offering safe positive-pressure ventilation without leaks when the ventilation face mask is not viable. It is presented in a box of 10 units with individual sterile packaging, ready for immediate use in the operating theatre, ICU and emergency services.

2. Technical explanation of the device and procedure

In orotracheal intubation, the tube is introduced through the mouth under laryngoscopic vision, passes through the glottis and is placed in the trachea, where it conducts gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. The cuff, inflated via the pilot balloon with self-sealing valve, seals the trachea and allows positive-pressure ventilation without significant leaks, also reducing the risk of aspiration of secretions.

The Murphy eye, a lateral opening located at the distal end, acts as an alternative gas passage: if the tip of the tube becomes obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening. The Magill curve, the rounded atraumatic tip, the radiopaque line and the depth marks facilitate safe placement and radiographic verification. It is a single-use device: after each patient it must be discarded to avoid the risk of cross-infection.

3. Technical Specifications

Parameter Specification
Reference ETAN70C02 (distributor SKU Cahnos)
Type Oral endotracheal tube (Magill curve) with cuff and Murphy eye
Internal diameter (ID) 7.0 mm (standard adult size)
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Sleeve Yes, inflatable, with pilot balloon and self-sealing valve
Murphy eye Yes, distal lateral safety opening
Tip Atraumatic, rounded and gently bevelled
Connector Universal 15 mm, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque line and depth marks
Use Single-use (sterile, individual packaging)
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Presentation Box of 10 units

Note: the outer diameter (OD), total length and optimal cuff inflation pressure for this size could not be verified in official public sources from the manufacturer; they remain pending confirmation with the technical department before use in tenders or stock replacement.

Other sizes from the same family (ETAN series, same oral design with cuff and Murphy eye, catalogue Cahnos)

Inner diameter SKU (box of 10 units)
2.5 mm ETAN25C02
3.0 mm ETAN30C02
3.5 mm ETAN35C02
4.0 mm ETAN40C02
4.5 mm ETAN45C02
5.5 mm ETAN55C02
6.5 mm ETAN65C02
7.0 mm ETAN70C02 (this product)
7.5 mm ETAN75C02
8.0 mm ETAN80C02
10.0 mm ETAN10C02

This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE marking on each supplied batch.

4. Equivalences and Cross-References

The SKU ETAN70C02 is a proprietary code of Cahnos and the ETAN family corresponds to the nomenclature of the DEAFLUX line (DEAS S.r.l.) of Magill tracheal tubes with cuff. It should not be confused with other lines from the same manufacturer (preformed ETPO/ETPN, suction lumen ETSL or reinforced ETA) nor with the official part number of any other manufacturer. Therefore, an exact reference equivalence cannot be declared nor is there an equivalence table validated by the manufacturer; consult the technical department of Cahnos before using this reference in specifications or tenders.

Comparable at category level (not interchangeable 1:1)

Manufacturer / Line Reference Observations
Endosid (catalogue Cahnos), tube with cuff and Murphy eye ID 7.0 mm 841070 Same configuration and size; differs in PVC compound, length and cuff design
P. J. Dahlhausen, Magill line with low-pressure, high-volume cuff 44.000.10.070 Same indication and general geometry; verify data sheet by data sheet
ISSO PRO-BREATHE, preformed tube with cuff ID 7.0 mm PBET41270 Comparable by category; preformed, not a direct substitute for the oral Magill
Teleflex / Rüsch® Safety Clear® Plus Series 1120820xx (7.0 mm) Differs in material (Ruschelit®), length and cuff design; pending confirmation by exact code
ICU Medical / Portex™ SOFT-SEAL™ Series 100/199/0xx (7.0 mm) Differs in cuff system, length and distal profile; pending confirmation by exact code

Comparable by category within the Cahnos catalogue (same ID 7.0 mm, other configurations): 840070 (Endosid Magill without cuff), 843070 (Endosid without cuff with Murphy eye), 845070 (intubation kit with stylet and syringe), ETPO70C02 (preformed oral), ETSL70C02 (subglottic suction lumen) and ETA070C02A2 (reinforced). All are comparable at category level, not interchangeable 1:1.

5. Selection tips and variants of interest

Selection by patient (usual use in clinical practice, not manufacturer specification): the ID 7.0 mm size is a reference size in adults, frequently used in women or patients of medium build; as a general guide, tubes from 7.0 to 9.0 mm are used according to age, weight and build, always selecting the largest size compatible with the patient’s anatomy and the service protocol.

Cuff pressure: inflate via the pilot balloon with a syringe and maintain a sealing pressure around 20–30 cmH₂O (usual range in clinical practice) to minimise damage to the tracheal mucosa; monitor with a manometer if the service has one. Before intubation, check the integrity of the cuff, the pilot balloon and the patency of the lumen.

Variants of interest in the Cahnos catalogue: if you need another size, the ETAN series covers from 2.5 mm to 10.0 mm (ETAN25C02 to ETAN10C02). For prolonged ventilation with secretion drainage, consider the tube with subglottic suction lumen (ETSL70C02); for procedures requiring resistance to kinking or frequent repositioning, the reinforced tubes in the intubation section (ETA070C02A2); and for oral, maxillofacial or ENT surgery where it is desirable to keep the circuit out of the surgical field, the preformed ones (ETPO70C02). Recommended accessories: Luer-type syringe or manometer for inflation, tube fixator and water-soluble lubricant. Contact the technical department of Cahnos for samples, volume conditions and hospital supply lead times.

Additional information

Reference

ETAN70C02

Product type

Oral endotracheal tube (Magill curve) with cuff and Murphy eye

Inner diameter

7.0 mm

Material

Medical-grade polyvinyl chloride (PVC), latex-free

Sleeve

Yes, inflatable, with pilot balloon and self-sealing valve

Murphy eye

Yes, distal lateral safety opening

Connector

Universal 15 mm (ISO 5356-1)

Marking

Radiopaque line and depth marks

Sterilisation

Ethylene oxide (EO), sterile, individual packaging

Use

Single-use, disposable

Presentation

Box of 10 units

Indications

Positive pressure ventilation and anaesthesia administration when face mask is not viable

Regulatory standard

ISO 5361 (tracheal tubes and connectors)

Reviews

There are no reviews yet.

Be the first to review “Oral Endotracheal Tube with Cuff and Murphy Eye ID 7.0 mm | Medical-Grade PVC, Single-Use, Box of 10 units (Ref. ETAN70C02)”

Your email address will not be published. Required fields are marked *