Description
1. Introduction
The oral endotracheal tube with cuff and Murphy eye of 7.0 mm (ref. ETAN70C02) is a single-use airway device designed for orotracheal intubation of adult patients in anaesthesia, intensive care, emergency and resuscitation. Made of medical-grade PVC, latex-free, it combines a low-pressure sealing cuff with the characteristic lateral Murphy eye, offering safe positive-pressure ventilation without leaks when the ventilation face mask is not viable. It is presented in a box of 10 units with individual sterile packaging, ready for immediate use in the operating theatre, ICU and emergency services.
2. Technical explanation of the device and procedure
In orotracheal intubation, the tube is introduced through the mouth under laryngoscopic vision, passes through the glottis and is placed in the trachea, where it conducts gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. The cuff, inflated via the pilot balloon with self-sealing valve, seals the trachea and allows positive-pressure ventilation without significant leaks, also reducing the risk of aspiration of secretions.
The Murphy eye, a lateral opening located at the distal end, acts as an alternative gas passage: if the tip of the tube becomes obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening. The Magill curve, the rounded atraumatic tip, the radiopaque line and the depth marks facilitate safe placement and radiographic verification. It is a single-use device: after each patient it must be discarded to avoid the risk of cross-infection.
3. Technical Specifications
| Parameter | Specification |
| Reference | ETAN70C02 (distributor SKU Cahnos) |
| Type | Oral endotracheal tube (Magill curve) with cuff and Murphy eye |
| Internal diameter (ID) | 7.0 mm (standard adult size) |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Sleeve | Yes, inflatable, with pilot balloon and self-sealing valve |
| Murphy eye | Yes, distal lateral safety opening |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque line and depth marks |
| Use | Single-use (sterile, individual packaging) |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
Note: the outer diameter (OD), total length and optimal cuff inflation pressure for this size could not be verified in official public sources from the manufacturer; they remain pending confirmation with the technical department before use in tenders or stock replacement.
Other sizes from the same family (ETAN series, same oral design with cuff and Murphy eye, catalogue Cahnos)
| Inner diameter | SKU (box of 10 units) |
| 2.5 mm | ETAN25C02 |
| 3.0 mm | ETAN30C02 |
| 3.5 mm | ETAN35C02 |
| 4.0 mm | ETAN40C02 |
| 4.5 mm | ETAN45C02 |
| 5.5 mm | ETAN55C02 |
| 6.5 mm | ETAN65C02 |
| 7.0 mm | ETAN70C02 (this product) |
| 7.5 mm | ETAN75C02 |
| 8.0 mm | ETAN80C02 |
| 10.0 mm | ETAN10C02 |
This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE marking on each supplied batch.
4. Equivalences and Cross-References
The SKU ETAN70C02 is a proprietary code of Cahnos and the ETAN family corresponds to the nomenclature of the DEAFLUX line (DEAS S.r.l.) of Magill tracheal tubes with cuff. It should not be confused with other lines from the same manufacturer (preformed ETPO/ETPN, suction lumen ETSL or reinforced ETA) nor with the official part number of any other manufacturer. Therefore, an exact reference equivalence cannot be declared nor is there an equivalence table validated by the manufacturer; consult the technical department of Cahnos before using this reference in specifications or tenders.
Comparable at category level (not interchangeable 1:1)
| Manufacturer / Line | Reference | Observations |
| Endosid (catalogue Cahnos), tube with cuff and Murphy eye ID 7.0 mm | 841070 | Same configuration and size; differs in PVC compound, length and cuff design |
| P. J. Dahlhausen, Magill line with low-pressure, high-volume cuff | 44.000.10.070 | Same indication and general geometry; verify data sheet by data sheet |
| ISSO PRO-BREATHE, preformed tube with cuff ID 7.0 mm | PBET41270 | Comparable by category; preformed, not a direct substitute for the oral Magill |
| Teleflex / Rüsch® Safety Clear® Plus | Series 1120820xx (7.0 mm) | Differs in material (Ruschelit®), length and cuff design; pending confirmation by exact code |
| ICU Medical / Portex™ SOFT-SEAL™ | Series 100/199/0xx (7.0 mm) | Differs in cuff system, length and distal profile; pending confirmation by exact code |
Comparable by category within the Cahnos catalogue (same ID 7.0 mm, other configurations): 840070 (Endosid Magill without cuff), 843070 (Endosid without cuff with Murphy eye), 845070 (intubation kit with stylet and syringe), ETPO70C02 (preformed oral), ETSL70C02 (subglottic suction lumen) and ETA070C02A2 (reinforced). All are comparable at category level, not interchangeable 1:1.
5. Selection tips and variants of interest
Selection by patient (usual use in clinical practice, not manufacturer specification): the ID 7.0 mm size is a reference size in adults, frequently used in women or patients of medium build; as a general guide, tubes from 7.0 to 9.0 mm are used according to age, weight and build, always selecting the largest size compatible with the patient’s anatomy and the service protocol.
Cuff pressure: inflate via the pilot balloon with a syringe and maintain a sealing pressure around 20–30 cmH₂O (usual range in clinical practice) to minimise damage to the tracheal mucosa; monitor with a manometer if the service has one. Before intubation, check the integrity of the cuff, the pilot balloon and the patency of the lumen.
Variants of interest in the Cahnos catalogue: if you need another size, the ETAN series covers from 2.5 mm to 10.0 mm (ETAN25C02 to ETAN10C02). For prolonged ventilation with secretion drainage, consider the tube with subglottic suction lumen (ETSL70C02); for procedures requiring resistance to kinking or frequent repositioning, the reinforced tubes in the intubation section (ETA070C02A2); and for oral, maxillofacial or ENT surgery where it is desirable to keep the circuit out of the surgical field, the preformed ones (ETPO70C02). Recommended accessories: Luer-type syringe or manometer for inflation, tube fixator and water-soluble lubricant. Contact the technical department of Cahnos for samples, volume conditions and hospital supply lead times.