Description
1. Introduction
Oral Endotracheal Tube with Cuff and Murphy Eye, 4.0 mm (Ref. ETAN40C02) is a single-use airway device designed for orotracheal intubation in paediatric and adult patients with a reduced-calibre airway. Made from medical-grade polyvinyl chloride (PVC), it combines an effective sealing cuff with the classic Murphy eye, offering anaesthetists, intensivists and emergency professionals a reliable, safe and easy-to-use solution in critical settings such as the operating theatre, ICU and emergency services. Its presentation in a box of 10 units, individually packaged and sterile, ensures hospital stock is always available.
2. Technical explanation of the device and procedure
In orotracheal intubation, the tube is inserted through the mouth under laryngoscopic vision, passes through the glottis and sits in the trachea, where it conducts gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. The cuff, inflated via the pilot balloon with a self-sealing valve, seals the trachea and allows positive-pressure ventilation without significant leaks, also reducing the risk of aspiration of gastric contents. The Murphy eye, a lateral opening at the distal end, acts as an alternative gas passage if the main lumen becomes obstructed by secretions or by the bevel resting against the tracheal wall, ensuring continuity of ventilation. The Magill curve, rounded atraumatic tip, radiopaque contrast line and depth markings facilitate safe placement and radiographic verification. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.
3. Technical Specifications
| Parameter | Specification |
| Reference (SKU) | ETAN40C02 |
| Type | Oral endotracheal tube (Magill curve) with cuff and Murphy eye |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 4.0 mm |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, flexible and durable |
| Latex | Natural latex-free |
| Sleeve | Yes, inflatable, with pilot balloon and self-sealing valve |
| Murphy eye | Yes, distal lateral safety opening |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth graduation |
| Sterilisation | Ethylene oxide (EO), sterile, individually packaged |
| Use | Single-use, disposable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the declaration of conformity and the manufacturer’s CE/MDR marking on each supplied batch.
The ETAN series (the family to which this product belongs) covers the following sizes in the same configuration and 10-unit box presentation:
| Inner diameter | Reference (box of 10 units) |
| 2.5 mm | ETAN25C02 |
| 3.0 mm | ETAN30C02 |
| 3.5 mm | ETAN35C02 |
| 4.0 mm | ETAN40C02 (this product) |
| 4.5 mm | ETAN45C02 |
| 5.0 mm | ETAN50C02 |
| 5.5 mm | ETAN55C02 |
| 6.0 mm | ETAN60C02 |
| 6.5 mm | ETAN65C02 |
| 7.0 mm | ETAN70C02 |
| 7.5 mm | ETAN75C02 |
| 8.0 mm | ETAN80C02 |
| 8.5 mm | ETAN85C02 |
| 9.0 mm | ETAN90C02 |
| 9.5 mm | ETAN95C02 |
| 10.0 mm | ETAN10C02 |
4. Equivalences and Cross-References
The SKU ETAN40C02 is Cahnos’s own code and the ETAN family corresponds to the nomenclature of the DEAFLUX line of Magill tracheal tubes with cuff; it should not be confused with the official part number of any specific manufacturer. To date, there is no manufacturer-validated equivalence table for this reference; we therefore classify the following options according to their degree of correspondence:
Confirmed in Cahnos’s own catalogue (same configuration, 4.0 mm calibre, with cuff and Murphy eye): the ENDOSID tube with low-pressure cuff and Murphy eye Ref. 841040, which shares indication, calibre and general geometry with the cuff; it may differ in brand and inflation system.
Comparable at category level (same 4.0 mm calibre, not interchangeable 1:1): PRO-BREATHE tube from ISSO Ref. PB-212040U and Magill tracheal tubes with cuff from series 44.000.10.040 / 44.000.11.040 (P. J. Dahlhausen). They may differ in PVC compound, length, cuff inflation pressure and bevel design.
As complementary references of the same 4.0 mm calibre in the Cahnos catalogue: the Magill tube without cuff Ref. 840040, the version without cuff and without Murphy eye Ref. 842040, the version without cuff with Murphy eye Ref. 843040, the endotracheal tube without cuff Ref. ETAN40002 and the emergency intubation kit Ref. 845040. There is no manufacturer-validated equivalence table for this reference; consult the technical department of Cahnos before using this reference as an equivalence in tenders or bids.
5. Selection tips and variants of interest
Selection by patient (usual use in clinical practice, not manufacturer specification): the 4.0 mm ID calibre is used in infants and young children (general guidance: 3.5–5.0 mm for this range), as well as in patients with a reduced-calibre airway; the final choice should be based on the age, weight and individual anaesthetic assessment of each patient.
Cuff pressure: check the integrity of the cuff, the pilot balloon and the patency of the lumen before intubation; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise the risk of pressure injury to the tracheal mucosa, monitoring with a manometer if the service has one available.
Variants of interest in the Cahnos catalogue: if you need another calibre, the ETAN series covers from 2.5 mm to 10.0 mm (ETAN25C02 to ETAN10C02) in the same configuration. If you prefer a completely smooth internal lumen, consider the versions without Murphy eye from the ENDOSID family; for long-duration procedures requiring an airtight seal, the ENDOSID with low-pressure cuff (Ref. 841040); in case of risk of kinking or frequent repositioning, the reinforced tubes from the intubation section; and for oral or maxillofacial surgery, the preformed ones. Contact Cahnos’s technical department for samples, volume conditions and hospital supply lead times.





Reviews