Description
1. Introduction
The Oral Endotracheal Tube with Cuff and Murphy Eye, ID 3.0 mm (Ref. ETAN30C02) is the airway solution that anaesthesia, emergency and intensive care services need to ensure ventilation of paediatric patients or patients with a reduced airway calibre when a face mask is not a viable option. Made of medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines a sealing cuff with pilot balloon and the distal Murphy eye to provide safe positive pressure ventilation, without significant leaks and with protection against obstructions. It is supplied in a box of 10 units, individually packaged and sterile, designed to keep hospital stock always available on the intubation trolley, operating theatre and paediatric ICU.
2. Technical explanation of the device and procedure
In orotracheal intubation, the tube is inserted through the mouth under laryngoscopic vision, passes through the glottis and sits in the trachea, where it conducts gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. The cuff, inflated through the pilot balloon with self-sealing valve, seals the trachea and allows positive pressure ventilation without leaks, also reducing the risk of aspiration. The Murphy eye, a lateral opening located at the distal end, acts as an alternative gas passage: if the main lumen were obstructed by secretions or by the bevel resting against the tracheal wall, flow continues through this opening and occlusion is never total. The Magill-type curve, the rounded atraumatic tip, the radiopaque line and the depth marks facilitate safe placement and radiographic verification. It is a single-use device: after each patient it must be discarded to avoid the risk of cross-infection.
3. Technical Specifications
| Parameter | Specification |
| Reference (SKU) | ETAN30C02 (own code Cahnos, ETAN series) |
| Access route | Oral (orotracheal), Magill-type curve |
| Internal diameter (ID) | 3.0 mm |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Sleeve | Yes, inflatable, with pilot balloon and self-sealing valve |
| Murphy eye | Yes, distal lateral safety opening |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque line and depth marks |
| Sterilisation | Ethylene oxide (EO), sterile, individually packaged |
| Use | Single-use, disposable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
ETAN series with cuff – same oral configuration with cuff and Murphy eye (box of 10 units):
| Inner diameter | Reference (box of 10 units) |
| 2.5 mm | ETAN25C02 |
| 3.0 mm | ETAN30C02 (this product) |
| 3.5 mm | ETAN35C02 |
| 4.0 mm | ETAN40C02 |
| 4.5 mm | ETAN45C02 |
| 5.5 mm | ETAN55C02 |
| 6.5 mm | ETAN65C02 |
| 7.0 mm | ETAN70C02 |
| 7.5 mm | ETAN75C02 |
| 8.0 mm | ETAN80C02 |
| 10.0 mm | ETAN10C02 |
Note: tracheal tubes are manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE/MDR marking on each supplied batch. The outer diameter (OD), total length and recommended cuff inflation pressure in this size could not be verified in official public sources from the manufacturer; they are pending confirmation with the technical department before use in tenders or stock replacement.
4. Equivalences and Cross-References
The SKU ETAN30C02 is an in-house code of Cahnos (ETAN series); the ETAN family follows the nomenclature of the DEAFLUX line of Magill tracheal tubes, but it should not be confused with the official part number of any specific manufacturer. To date, there is no equivalence table validated by the manufacturer for this reference, so the following options are classified as comparable at category level (not 1:1 interchangeable), pending technical verification against each manufacturer’s official data sheet:
| Reference | Description | Key difference |
| 841030 (Endosid, catalogue Cahnos) | Endotracheal tube with low-pressure cuff and Murphy eye, ID 3.0 mm | Same configuration and size; the manufacturer of origin and supply format differ. |
| ETAN35C02 / ETAN40C02 (Cahnos) | Same ETAN series with cuff in sizes 3.5 and 4.0 mm | Only the internal diameter varies |
| Teleflex (Rüsch®) / ICU Medical (Portex™) / Medtronic (Shiley™) / Intersurgical | Market ranges of paediatric tracheal tubes with cuff | Same general clinical indication; verify in each technical data sheet the ID, material, presence of Murphy eye and sterilisation standard |
In paediatric sizes (3.0 mm), the exact references from third-party manufacturers could not be verified in official public sources and remain pending confirmation with the manufacturer/distributor. This reference must not be presented as a direct substitute for another brand without technical validation. There is no equivalence table validated by the manufacturer; consult the technical department of Cahnos before using this reference in tender documents or tenders.
5. Selection tips and variants of interest
Size selection (usual use in clinical practice, not manufacturer specification): the 3.0 mm ID is intended for small paediatric patients, infants or reduced-calibre airways where a tight seal with cuff is required; as a general guideline, in paediatrics tubes from 2.5 to 4.5 mm are used according to age and weight, always selecting the largest size compatible with the patient’s anatomy and according to the service protocol.
Cuff pressure: check the integrity of the cuff, pilot balloon and valve before intubation; inflate with a syringe and maintain a sealing pressure around 20–30 cmH₂O (usual clinical practice range) to minimise damage to the tracheal mucosa, monitoring with a manometer if the service has one available.
Variants of interest in the Cahnos catalogue: if you need another size, the ETAN series with cuff covers from 2.5 mm to 10.0 mm (ETAN25C02 to ETAN10C02). For procedures requiring kink resistance or frequent repositioning, consider the reinforced tube with cuff from the intubation section; for head and neck or ENT surgery, the preformed ones; and for prolonged ventilation with secretion drainage, tubes with subglottic suction lumen. Contact the technical-commercial department of Cahnos for samples, volume conditions and the approval of references for your tender.




Reviews