Oral Endotracheal Tube with Cuff and Murphy Eye – ID 2.5 mm | Medical-Grade PVC, Single-Use, Neonatal Intubation, Box of 10 units (Ref. ETAN25C02)

16,05 €

Oral endotracheal tube with cuff and Murphy eye, 2.5 mm internal diameter (Ref. ETAN25C02), manufactured from medical-grade polyvinyl chloride (PVC) and latex-free. Indicated for neonatal intubation and very small-calibre airways, positive-pressure ventilation and administration of anaesthesia when a ventilation face mask is not feasible. Incorporates a sealing cuff with pilot balloon, distal Murphy safety eye, radiopaque line and universal 15 mm connector (ISO 5356-1). Presentation in a box of 10 units, single-use, ideal for NICU, paediatric operating theatre, emergency departments and intubation trolleys. Immediate availability and delivery throughout Spain.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETAN25C02

Description

1. Introduction

The oral endotracheal tube with cuff and Murphy eye, ID 2.5 mm (Ref. ETAN25C02) is a single-use airway management device, specifically designed for intubation of neonates, premature infants and patients with very small-calibre airways. It is part of the Cahnos ETAN family and is supplied in a box of 10 units, a cost-effective solution for keeping the NICU intubation trolley, paediatric operating theatre and emergency department always operational. Its construction in medical-grade PVC, transparent and latex-free, offers the right combination of flexibility and controlled rigidity for guided and safe placement.

2. Technical explanation of the device and procedure

In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and sits in the trachea, where it delivers gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The sealing cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen against the tube: it prevents gas leaks during positive-pressure ventilation, prevents aspiration of secretions and stabilises the device during mechanical ventilation. The Murphy eye, a lateral opening at the distal end, acts as a safety pathway: if the tip were obstructed by secretions or by the bevel resting against the tracheal wall, respiratory flow continues through this opening and occlusion is never complete. The longitudinal radiopaque line and depth marks allow radiographic verification of correct placement. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.

3. Technical Specifications

Parameter Specification
Reference (SKU) ETAN25C02 (own code Cahnos)
Type Oral endotracheal tube (Magill-type curvature) with cuff and Murphy eye
Access route Oral (orotracheal)
Internal diameter (ID) 2.5 mm
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Sleeve Yes, sealing, with pilot balloon and self-sealing valve
Murphy eye Yes, distal lateral safety opening
Connector Universal 15 mm, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque line and depth marks
Use Single-use (sterile, individually packaged)
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Presentation Box of 10 units

Technical note: the outer diameter (OD) and total length of this size could not be verified in official public sources; they remain pending confirmation with the manufacturer before use in tendering or stock replacement.

ETAN range of oral tubes with cuff and Murphy eye (Cahnos catalogue):

Reference Internal diameter (ID)
ETAN25C02 (this product) 2.5 mm
ETAN30C02 3.0 mm
ETAN35C02 3.5 mm
ETAN40C02 4.0 mm
ETAN45C02 4.5 mm
ETAN50C02 5.0 mm
ETAN55C02 5.5 mm
ETAN60C02 6.0 mm
ETAN65C02 6.5 mm
ETAN70C02 7.0 mm
ETAN75C02 7.5 mm
ETAN80C02 8.0 mm
ETAN85C02 8.5 mm
ETAN90C02 9.0 mm
ETAN95C02 9.5 mm
ETAN10C02 10.0 mm

This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the declaration of conformity and the manufacturer’s CE/MDR marking on each supplied batch.

4. Equivalences and Cross-References

The SKU ETAN25C02 is a proprietary code from the Cahnos catalogue, and the ETAN family corresponds to the nomenclature of the DEAFLUX line (DEAS S.r.l., Italy) of Magill-type tracheal tubes with cuff; it must not be confused with the official part number of any specific manufacturer or with other lines from the same company (ETPO/ETPN preformed, ETSL subglottic suction lumen, or ETA/ETAM reinforced). Therefore, an exact reference equivalence cannot be declared.

Comparable at category level (not 1:1 interchangeable):

  • 841025 – ENDOSID tube with low-pressure cuff and Murphy eye, same size 2.5 mm (Cahnos own catalogue): shares indication, size and cuff configuration; the PVC compound, length and inflation system may differ.
  • PB-212025U – ISSO PRO-BREATHE, suction line, size 2.5: comparable by category; verify cuff type, presence of Murphy eye and connector standard.
  • 44.000.10.025 and 44.000.11.025 – P. J. Dahlhausen, Magill-type tracheal tubes with and without cuff, size 2.5 mm (series documented in the manufacturer’s official catalogue).
  • Ranges from Teleflex (Rüsch), Medtronic (Shiley) and ICU Medical (Portex): same functional families of cuffed tracheal tubes; no specific codes verified for this size against an official source.

There is no equivalence table validated by the manufacturer for reference ETAN25C02; consult the Cahnos technical department before using this reference in specifications, tenders or stock replacement.

5. Selection tips and variants of interest

  • Selection by patient (usual practice in clinical use, not manufacturer specification): the ID 2.5 mm size is intended for neonates and premature infants; as a general guide, sizes from 2.0 to 3.5 mm are used in neonates depending on gestational age, weight and departmental protocol. In patients with a cuff, sealing should be minimal and monitored due to the risk of mucosal injury in immature airways.
  • Cuff pressure: inflate via the pilot balloon with a syringe and maintain a sealing pressure of 20–30 cmH2O (usual clinical practice range), monitoring with a manometer if available in the department; previously check the integrity of the cuff, pilot balloon and lumen patency.
  • Verification: after placement, confirm position using the radiopaque line and depth marks. Single-use product: do not re-sterilise or reuse.
  • Variants of interest in the Cahnos catalogue: if you need another size, the ETAN series covers from 2.5 mm to 10.0 mm (ETAN25C02 to ETAN10C02). In the same 2.5 mm size, the following are available: ENDOSID without cuff and without Murphy eye (Ref. 842025), without cuff with Murphy eye (Ref. 843025), standard Magill without cuff (Ref. 840025) and emergency intubation kit (Ref. 845025). For prolonged ventilation with a tight seal, the cuffed version 841025; for head and neck surgery, consult the preformed ranges (ETPO/ETPN).
  • Contact our technical-commercial team at Cahnos for reference approval, samples, volume conditions and hospital supply lead times.

Additional information

Reference

ETAN25C02 (own code Cahnos)

Product type

Oral endotracheal tube (Magill-type curvature) with cuff and Murphy eye

Access route

Oral (orotracheal)

Inner diameter

2.5 mm

Outer diameter (OD)

Pending confirmation with the manufacturer (not verified in public sources)

Material

Medical-grade polyvinyl chloride (PVC), latex-free

Sleeve

Yes, inflatable, with pilot balloon and self-sealing valve

Murphy eye

Yes, distal lateral safety opening

Connector

Universal 15 mm (ISO 5356-1)

Marking

Radiopaque line and depth marks

Sterilisation

Ethylene oxide (EO), individual sterile packaging

Use

Single-use, non-reusable

Indications

Positive pressure ventilation and anaesthesia administration

Indicative population

Neonates and very small-calibre airways

Presentation

Box of 10 units

Regulatory standard

ISO 5361 (tracheal tubes and connectors); connector ISO 5356-1

Reviews

There are no reviews yet.

Be the first to review “Oral Endotracheal Tube with Cuff and Murphy Eye – ID 2.5 mm | Medical-Grade PVC, Single-Use, Neonatal Intubation, Box of 10 units (Ref. ETAN25C02)”