Description
1. Introduction
The 5.5 mm cuffed endotracheal tube (ref. 57655) is a single-use airway device designed to ensure assisted and controlled ventilation in anaesthesia, emergency and intensive care units. Its high-volume, low-pressure sealing cuff allows effective tracheal sealing while minimising damage to the tracheal mucosa, while its resistant PVC walls keep the lumen open throughout the procedure. It is supplied sterile in a box of 100 units, ideal for continuous hospital supply.
2. Technical explanation of the device
In orotracheal intubation, the tube is inserted through the mouth, passes through the glottis and sits in the trachea to conduct gases from the ventilator or anaesthesia circuit to the lungs. The cuff, inflated via the pilot balloon with a one-way valve, seals the trachea and allows positive-pressure ventilation without significant leaks. The Murphy eye, a distal lateral orifice, ensures an alternative gas passage if the tube tip becomes obstructed by secretions or by the bevel resting against the tracheal wall. The radiopaque line and blunt tip design help confirm and maintain correct placement of the device, made of thermosensitive PVC that reduces the risk of kinking.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Manufacturer reference | 57655 |
| Type | Cuffed endotracheal tube, sterile |
| Diameter | 5.5 mm |
| Tube length | 27.5 cm |
| Material | PVC (resistant walls, thermosensitive) |
| Sleeve | High volume / low pressure, barrel shape, heat-sealed |
| Pilot balloon | Sensitive response |
| Tip | Blunt (bull-nose type) |
| Murphy eye | Yes, smooth |
| Marking | Crack-resistant radiopaque line |
| Sterility | Sterile, single-use |
| Minimum order | Box of 100 units |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Box of 100 units |
| Device type | Medical device |
| Device class | II A |
| CND | R010399 |
| EAN | 6972091920076 |
Key features
- High-volume, low-pressure barrel-shaped cuffs
- Sensitive response pilot balloons
- Finely heat-sealed cuffs
- Blunt tips (bull-nose)
- Crack-resistant radiopaque lines
- Smooth Murphy eyes
- Kink-resistant thermosensitive tubes
4. Equivalences and Cross-References
There is no 1:1 equivalence table validated by the manufacturer for reference 57655; any substitution must be checked against the official technical data sheet. At category level (cuffed endotracheal tube with Murphy eye of Ø 5.5 mm, not directly interchangeable), the Cahnos catalogue offers comparable references such as the preformed oral tube with balloon ETPO55C02 or the preformed nasal tube ETPN55C02, which share diameter and cuff design but differ in geometry, length and presentation. It is recommended to consult the Cahnos technical department before using this reference in tenders or specifications.
5. Selection tips and variants of interest
The 5.5 mm size is commonly used in older paediatric patients, adolescents or adults with a narrow airway; the final choice should be based on the department’s protocol and anaesthetic assessment. Inflate the cuff through the valve with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range), monitoring with a manometer if available in the department. Always check the integrity of the cuff, the pilot balloon and the patency of the lumen before intubation. If you need other sizes or configurations (preformed RAE tubes, reinforced tubes or intubation kits with stylet), consult the intubation section of the Cahnos catalogue.