Description
1. Introduction
The cuffed endotracheal tube, size 9.0 mm (ref. 57662), is a single-use airway device manufactured from medical-grade PVC, sterile and ready for immediate use in the operating theatre, intensive care units and emergency departments. Its resistant wall ensures adequate ventilation for all patients, while the range of available sizes allows a secure airway to be maintained throughout the surgical procedure.
2. Technical explanation of the device and procedure
In orotracheal intubation, the tube is introduced through the mouth, passes through the glottis and is placed in the trachea to conduct gases from the ventilator or anaesthesia circuit to the lungs. The high-volume, low-pressure barrel-shaped cuff is inflated via the pilot balloon with self-sealing valve and seals the trachea, allowing positive-pressure ventilation without significant leaks and minimising damage to the tracheal mucosa.
The Murphy eye, a polished distal lateral opening, ensures an alternative gas passage if the tube tip becomes obstructed. The crack-resistant radiopaque lines and the thermo-sensitive properties of the tube (which adapts to body temperature) facilitate correct placement and reduce the risk of kinking. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | GIMA |
| Manufacturer reference | 57662 |
| Sales unit | Box of 100 units |
| Device type | Medical device |
| Device class | II A |
| CND | R010399 |
| EAN | 6972091920144 |
Tube features
| Parameter | Specification |
|---|---|
| Diameter | 9.0 mm |
| Tube length | 32.5 cm |
| Material | Medical-grade polyvinyl chloride (PVC), sterile |
| Sleeve | High volume, low pressure, barrel shape, heat-sealed |
| Pilot balloon | Sensitive, with self-sealing valve |
| Murphy eye | Yes, smooth |
| Tip | Rounded (bull-nose type) |
| Marking | Crack-resistant radiopaque line |
| Sterility | Yes, individually packaged |
| Use | Single-use |
Endotracheal tubes in this category are manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE marking on each supplied batch.
4. Equivalences and Cross-References
Reference 57662 corresponds to a standard cuffed endotracheal tube of 9.0 mm in a box of 100 units. A validated table of exact equivalences for this reference against other manufacturers is not currently available; cuffed 9.0 mm tubes from third-party lines may differ in length, cuff design and inflation pressure, and must therefore be checked against the official technical data sheet before use in tenders or stock replacement. Consult the Cahnos technical department to verify specific equivalences.
5. Selection tips and variants of interest
The 9.0 mm size is common in adult male patients of large build; as a general guide, tubes with an ID of 8.0–9.0 mm are typically used in men and 7.5–8.5 mm in women. The final choice must always be based on the department’s protocol and the anaesthetic assessment of each patient.
Cuff inflation: perform it through the valve using a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise tracheal damage; monitor with a manometer if the department has one. Before intubation, check the integrity of the cuff, the pilot balloon and the patency of the lumen.
If you need other sizes, the range of endotracheal tubes offers a wide range of diameters to cover from paediatric to adult patients. For approaches requiring kink resistance or frequent repositioning, consider the reinforced tubes in the intubation section of Cahnos. Contact the Cahnos technical department for samples, volume conditions and hospital supply lead times.