The cuffed endotracheal tube of Ø 6.0 mm is a single-use airway device, manufactured in polyvinyl chloride (PVC) and supplied sterile in a box of 100 units. A professional solution for anaesthesia, intensive care, operating theatre and emergency services that need to ensure reliable and continuous ventilation throughout the procedure, maintaining a patent and safe airway for the patient.
2. Technical explanation of the equipment and procedure
The tube is inserted orally or nasally through the glottis into the trachea and is connected at its proximal end to the ventilator, anaesthesia circuit or ventilation bag. Its high-volume, low-pressure cuff, once inflated via the pilot balloon, seals the tracheal lumen against the mucosal wall: it prevents gas leaks, reduces the risk of aspiration of secretions and minimises the pressure exerted on the tracheal mucosa, even during prolonged ventilation.
The design incorporates a smooth Murphy eye that acts as a backup ventilation pathway if the main lumen becomes obstructed by secretions or kinking, a crack-resistant radiopaque line for radiographic position control and a rounded tip that facilitates atraumatic insertion. The thermosensitive walls keep the tube flexible at room temperature and adapt to the shape of the airway at body temperature, resisting collapse and kinking during the procedure.
3. Technical Specifications
Product data verified in the manufacturer’s catalogue (.):
| Manufacturer | GIMA |
|---|---|
| Sales unit | Box of 100 units |
| Device type | Medical device |
| Device class | IIa |
| CND | R010399 |
| EAN | 6972091920083 |
| Manufacturer reference | 57656 |
|---|---|
| Diameter (Ø) | 6.0 mm |
| Tube length | 28.5 cm |
| Material | Medical-grade PVC (polyvinyl chloride), thermosensitive |
| Sleeve | High volume, low pressure, barrel-shaped, finely thermowelded |
| Pilot balloon | Sensitive / responsive |
| Murphy eye | Yes, smooth |
| Tip | Rounded (bull-nose type) |
| Radiopaque line | Yes, crack-resistant |
| Sterility / use | Sterile, single-use |
| Presentation | Box of 100 units |
Main design features:
- High-volume, low-pressure barrel-shaped cuffs
- Sensitive pilot balloons
- Finely thermowelded cuffs
- Rounded tips (bull-nose type)
- Crack-resistant radiopaque lines
- Smooth Murphy eyes
- Thermosensitive kink-resistant tubes
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer for reference 57656. As a functional category comparison (cuffed endotracheal tube with Murphy eye in internal diameter 6.0 mm), equivalent products by clinical indication can be found in the Cahnos catalogue and must be verified sheet by sheet before replacing a device in your care protocol:
| Reference | Description | Degree of correspondence |
|---|---|---|
| 841060 (ENDOSID) | Endotracheal tube with high-pressure balloon… high-volume, low-pressure balloon and Murphy eye, ID 6.0 mm | Comparable by category: same size and cuff configuration |
| ETAN60C02 (DEAFLUX) | Oral endotracheal tube with cuff and Murphy eye, 6.0 mm ID | Comparable by category: same size and configuration |
| 44.000.30.060 / 44.000.20.060 | Cuffed endotracheal tubes (nomenclature by size 6.0) | Comparable by category: verify manufacturer’s data sheet |
| ETSL60C02 | Tube with cuff and subglottic suction lumen, ID 6.0 mm | Advanced variant: adds subglottic suction (NAVM) |
It is always recommended to verify the internal diameter, cuff type and presence of a Murphy eye before replacing any reference with another in your intubation cart or tender specification.
5. Selection tips and variants of interest
The 6.0 mm size is intended for older paediatric patients, adolescents and adults of small build or with a reduced airway calibre; as a general guide, sizes from 7.0 to 8.5 mm are commonly used in adults, always selecting the largest size compatible with the patient’s anatomy.
Before intubation, check the integrity of the cuff and pilot balloon, and maintain the sealing pressure within the usual clinical practice range (20–30 cmH2O) to avoid injury to the tracheal mucosa. It is a single-use device: do not re-sterilise or reuse; discard it after removal according to the centre’s protocols.
To complete the equipment for your service, consult the other sizes in the range and the variants available in the Cahnos catalogue (reinforced tubes, with subglottic suction lumen or emergency intubation kits). Contact the technical-commercial department of Cahnos for volume conditions, samples and hospital supply lead times.