Description
1. Commercial Introduction
The MONOLUME (Ref. 770311) needle is a precision instrument designed for oocyte aspiration in in vitro fertilisation cycles and for aspiration of ovarian cysts. Its single-lumen construction, echogenic tip with atraumatic sharpening and universal connector ensures smooth penetration, stable ultrasound visualisation and safe recovery of follicular material, minimising tissue trauma. Presented in a box of 10 units, it is the professional supply solution for fertility clinics, assisted reproduction units and gynaecology practices seeking a sterile, single-use product with CE marking.
2. Technical explanation of the equipment and procedure
The MONOLUME needle is a simple single-channel needle intended for atraumatic oocyte retrieval in in vitro fertilisation procedures, as well as for drainage of ovarian cysts under ultrasound guidance. The echogenic tip with atraumatic sharpening (1) allows echo-guided retrieval with smooth, easy penetration of tissues. It incorporates a universal connector (3) for multiple connections and a female luer lock port (2) that acts as a handle and allows a secure connection to the syringe. Two lateral wings aligned with the sharpening of the tip help the operator to orientate during the penetration phase. The gauge is identified by the luer colour code: light blue for 16G and transparent for 17G.
In clinical practice, after preparing the vaginal area and the sterile field, the needle is attached to the ultrasound probe and introduced into the vagina following the trajectory on the monitor to the follicle or cyst, proceeding with gentle aspiration or drainage. It is a single-use product, sterilised by ethylene oxide (EtO), with CE 0051 marking, and may contain traces of nickel.
3. Technical Specifications
| Reference (SKU) | 770311 |
| Brand / family | MONOLUME |
| Product type | Oocyte and ovarian cyst aspiration needle |
| Configuration | Single channel, single lumen |
| Gauge | 17G |
| Length | 330 mm |
| Tip | Echogenic with atraumatic sharpening |
| Connection | Female luer lock port (handle) + universal connector for pump/syringe connection |
| Orientation | Two lateral wings aligned with the tip bevel |
| Gauge identification | Luer colour code: transparent (17G) / light blue (16G) |
| Use | Single-use (non-reusable) |
| Sterilisation | Ethylene oxide (EtO) — CE 0051 marking |
| Presentation | Box of 10 units, individually packaged |
| Application | Oocyte aspiration (IVF) and aspiration of ovarian cysts |
| Warning | May contain traces of nickel; do not use if the packaging is damaged |
4. Equivalences and Cross-References
Below are listed references from other manufacturers verified against official sources (manufacturer’s catalogue) for the same indication: ultrasound-guided oocyte aspiration with a single-lumen needle in gauge 17G and length close to 330 mm. None of them is interchangeable 1:1 without technical validation of each centre’s protocol.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cook Medical | Ovum Aspiration Needle Single Lumen (OPS), bevel A, thin wall | K-OPS-1733-T-A-60 (G55491) | Comparable by category, not interchangeable 1:1 | 17G × 33 cm (330 mm) with 60 cm aspiration line; EchoTip® echogenic tip and handle with orientation notch. Measurements equivalent to those of the MONOLUME. |
| CooperSurgical | Wallace® Single Lumen Oocyte Recovery | ON1733 | Comparable by category, not interchangeable 1:1 | 17G × 33 cm (330 mm) needle, non-coring triple-bevel tip, echogenic marking, presentation in box of 10 units; tube version: ONS1733. |
| Rocket Medical | Embryon® SX™ Single Lumen Aspiration Needle | R57602-00-SX | Comparable by category, not interchangeable 1:1 | 17G × 33 cm (330 mm) with 70 cm tube; high-definition ultrasound spiral needle tip and orientation marker on handle. |
| Gynemed | Oocyte Aspiration Needle, single lumen without flushing | GY-711724LF | Comparable by category, not interchangeable 1:1 | 17G × 32 cm (320 mm), single lumen without flushing, sterile by gamma irradiation, CE marking class IIa. Length 10 mm shorter than the MONOLUME. |
Other reference brands in the category of single-lumen oocyte needles (e.g. Vitrolife, with reference 17189 of 17G × 350 mm, or Gynetics FAS) have different lengths or connector designs and must be compared field by field (gauge, length, tip type, connection, sterility) before any substitution. There is no equivalence table validated by the manufacturer for 1:1 cross-reference with other brands; consult the technical department before use in tenders.
5. Selection tips and variants of interest
Gauge selection: the 17G model (Ref. 770311) offers a good balance between rigidity and flow; if your protocol requires a larger internal diameter for higher flow, consider the MONOLUME 16G version (Ref. 770312). Single lumen vs. follicular flushing: if in addition to aspirating you need to irrigate the follicle, consider the BIMONOCYTE family (Refs. 770302/770304 and versions with tube /TL) or the DOUBLECYTE double-lumen (Refs. 770308/770301). Versions with pump connection tube: the MONOCYTE-N series (Refs. 770307/TL) incorporate an 80 cm extension with luer lock connector for integration into pump suction systems. Good practices: single-use product, use it immediately after opening the packaging, verify the integrity of the packaging and dispose of it according to current legislation. For high volumes or framework agreements, consult our technical-commercial team.





Reviews