Description
1. Commercial Introduction
The BIMONOCYTE-N (Ref. 770302/TL) is a dual-channel oocyte aspiration and follicular flushing needle, designed for oocyte retrieval in in vitro fertilisation cycles with maximum safety, precision and respect for the gamete. Its -N version incorporates an 80 cm aspiration extension with transparent luer lock connector, allowing a clean, quick and stable connection to the operating theatre suction pump without intermediate couplings. It is presented in a box of 10 units with individual packaging, being the professional supply solution for fertility clinics, assisted reproduction units and gynaecology practices that require a sterile, single-use device with CE marking.
2. Technical explanation of the equipment and procedure
The BIMONOCYTE-N is a dual-channel needle with a single-lumen needle: the first channel is used for oocyte aspiration through the needle lumen and the second for follicular flushing, which runs through an external tube in transparent material connected via a Y-connector that also acts as a handle. It is composed of:
- Echogenic tip with atraumatic sharpening: smooth penetration and excellent visibility on the ultrasound scanner monitor, minimising follicular and tissue trauma.
- Blue-tinted tube: protects the oocyte from light and UV rays during aspiration.
- Medical thermoplastic rubber cap: connects securely to the collection tube.
- Y-connector (handle): connects the needle to the suction and flushing tubes, equipped with 2 universal accessories.
- Transparent follicular flushing line with stopcock: prevents reflux of the flushing fluid.
- Tube clamp: regulates follicular aspiration during the procedure.
- 80 cm extension with transparent luer lock connector: direct connection to the suction pump (-N version).
- Additional universal adapter included: compatible with a wide variety of connections.
In clinical practice, after preparing the vaginal area and the sterile field, the needle is attached to the guide of the ultrasound probe and inserted following the trajectory on the monitor to the follicle, proceeding with gentle aspiration of the cumulus-oocyte complex and follicular flushing. It is a single-use product, sterilised by ethylene oxide (EtO) with CE marking 0051.
3. Technical Specifications
| Parameter | Specification |
| Reference (SKU) | 770302/TL |
| Family / series | BIMONOCYTE-N (version with 80 cm extension for pump) |
| Product type | Dual-channel oocyte aspiration and follicular flushing needle (single-lumen needle) |
| Gauge | 17G (transparent luer lock) |
| Length | 330 mm |
| Tip | Echogenic with atraumatic sharpening |
| Aspiration channel | Needle lumen + 80 cm extension with Luer lock connector |
| Follicular flushing channel | Transparent external tube with anti-reflux stopcock and Y-connector with 2 universal accessories |
| Collection cap | Medical thermoplastic rubber for collection tube |
| Oocyte protection | Blue-tinted tube against UV rays |
| Orientation | Two lateral wings aligned with the tip bevel |
| Sterilisation | Ethylene oxide (EtO) — CE 0051 marking |
| Use | Single-use (non-reusable) |
| Presentation | Box of 10 units, individually packaged |
| Indication | Oocyte aspiration and follicular flushing in assisted reproduction (IVF / OPU) |
BIMONOCYTE / BIMONOCYTE-N family variants:
| Reference (without tube) | Reference (with 80 cm extension) | Gauge | Luer lock connector colour | Presentation |
| 770304 | 770304/TL | 16G × 330 mm | Azzurro (blue) | Box of 10 units |
| 770302 | 770302/TL (this product) | 17G × 330 mm | Transparent | Box of 10 units |
4. Equivalences and Cross-References
Below are listed references from other manufacturers verified against official sources (technical data sheets and manufacturer IFU and GUDID/FDA regulatory database) for the same indication: transvaginal ultrasound-guided oocyte aspiration with follicular flushing (dual-channel) in 17G gauge and length close to 330 mm. None of them is interchangeable 1:1 without technical validation of each centre’s protocol.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cook Medical | EchoTip® Double Lumen Ovum Aspiration Needle (K-OPSD series) | K-OPSD-1733-A-S-US | Comparable by category (not interchangeable 1:1) | 17G × 33 cm (330 mm) with double lumen in needle, 75 cm aspiration line and 70 cm flushing line (S version); EchoTip® echogenic tip and handle with bevel orientation marker (Cook IFU). |
| CooperSurgical | Wallace® Dual Lumen Oocyte Recovery Set | DNS1733-950 | Comparable by category (not interchangeable 1:1) | 17G × 33 cm (330 mm) with 950 mm aspiration tube and integrated flushing line; non-coring tri-beveiled tip with echogenic marking to the tip; box of 10 units (verified in GUDID). |
| Gynemed | FAS Follicle Aspiration Needle double lumen with flushing | GY-931768LF | Comparable by category (not interchangeable 1:1) | 17G × 32 cm (320 mm), double lumen with flushing and stopcock in the handle; sterilisation by gamma irradiation, CE marking class IIa. Length 10 mm shorter than the BIMONOCYTE-N. |
| Kitazato | Double Lumen OPU Needle (with aspiration line) | 377350 | Comparable by category (not interchangeable 1:1) | 17G × 35 cm (350 mm), 80 cm aspiration line and 100 cm flushing line; thin-wall technology and tip with echogenic marking; tested with MEA assay. Length 20 mm longer than the BIMONOCYTE-N. |
Other reference brands in the category of oocyte needles with follicular flushing (for example, Vitrolife or the FAS line from Gynetics, or Rocket Medical, whose Embryon® double-lumen needle is only marketed in 16G gauge: R57610 and R57611) have different lengths, gauges or connection designs and must be compared field by field (gauge, length, tip type, connection, sterility) before any substitution. There is no equivalence table validated by the manufacturer for 1:1 cross-reference with other brands; consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Gauge selection: the 17G model (Ref. 770302/TL) offers an excellent balance between rigidity and flow with less trauma; if your protocol requires a larger internal diameter and higher aspiration flow, consider the BIMONOCYTE-N 16G version (Ref. 770304/TL), with blue connector.
- With tube (-N version) vs. without tube: the BIMONOCYTE-N series includes an 80 cm extension with luer lock to integrate into pump suction systems; the BIMONOCYTE version without extension (Ref. 770302) connects directly via luer lock to a syringe or equipment line.
- Dual-channel vs. true double lumen in needle: the BIMONOCYTE-N performs follicular flushing via an external route (single-lumen needle); if you need the flushing to run through a second internal lumen of the needle, consider the DOUBLECYTE-N double-lumen family (Refs. 770308/TL in 17G and 770301/TL in 16G).
- Without follicular flushing: if you only require aspiration, the MONOCYTE-N single-lumen series (Ref. 770307/TL in 17G) or the MONOLUME range (Refs. 770311 in 17G and 770312 in 16G) cover this indication more economically.
- Good practices: single-use product and sterile by EtO; use it immediately after opening the packaging, check the integrity of the packaging and dispose of it according to current legislation. For high volumes or framework agreements, consult our technical-commercial team.





Reviews