We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Uterine injector Injector Plus for hysterosalpingography (HSG) – Semi-rigid radiopaque catheter 6 Fr, double-lumen and 2.5 cc balloon (Box of 10 units) | Ref. 730226

24,00 €

The Injector Plus for hysterosalpingography (Ref. 730226) is a uterine injector with a semi-rigid radiopaque double-lumen catheter and 6 Fr (2.0 mm), fitted with a 2.5 cc distal oval balloon that ensures stable fixation and prevents reflux of the contrast medium. It includes a steel stylet for guided cervical insertion, stopcock, anti-reflux clamp, 2.5 cc syringe and female Luer-Lock connector. Sterile, single-use, in a box of 10 units. Ideal for assisted reproduction, fertility diagnostics and gynaecological radiology.

International shipping. Import duties and taxes are payable by the recipient.

Reference
730226
Tags

Description

1. Introduction

The Injector Plus (Ref. 730226) is a disposable uterine injector designed by the Italian manufacturer RI.MOS for diagnostic procedures of hysterosalpingography (HSG) and sonohysterography. Its semi-rigid catheter system with distal balloon allows controlled injection of the contrast medium, obtaining clear images of the uterine cavity and the patency of the fallopian tubes. A reliable, single-use solution for assisted reproduction units, gynaecology clinics and radiology departments, supplied in a box of 10 units.

2. Technical explanation of the equipment

This device is specifically designed for the injection of radiopaque contrast medium or methylene blue during hysterosalpingography. The set consists of a rigid introducer with sliding stop that guides catheter placement, and a semi-rigid radiopaque double-lumen catheter: one lumen is used for contrast injection and the other for inflation of the distal oval balloon of 2.5 cc. When inflated, the balloon occludes the internal cervical os, fixes the catheter in the correct position and minimises reflux of contrast into the vagina, favouring uterine distension and visualisation of the tubes. The steel stylet facilitates passage through the cervix and provides rigidity during insertion; the stopcock regulates balloon inflation, the anti-reflux clamp prevents fluid leakage and the female Luer-Lock connector ensures a secure connection with the included 2.5 cc syringe. The entire set is supplied sterile, individually packaged and ready for single-use.

3. Technical Specifications

The system integrates all the elements needed to perform the procedure quickly, safely and reproducibly.

Component Technical description
Catheter (1) Semi-rigid, radiopaque, double-lumen (2 channels); outer Ø 2 mm (6 Fr); distal oval balloon of thermoplastic rubber, 2.5 cc
Rigid introducer (2) With adjustable sliding stop to guide placement
Syringe (3) 2.5 cc capacity for balloon inflation
Valve / stopcock (4) Regulates inflation of the distal balloon
Anti-reflux clamp (5) Retaining collar that prevents fluid reflux
Connector (6) Female Luer-Lock for injection of the contrast medium
Stylet (7) Steel, facilitates insertion through the cervix

Technical data

Parameter Value
Catheter outer diameter 2 mm (6 Fr)
Configuration Semi-rigid radiopaque double-lumen
Distal balloon Oval, thermoplastic rubber, 2.5 cc
Fixation system Balloon inflation + anti-reflux clamp
Connection Female Luer-Lock
Compatible media Radiopaque contrast or methylene blue
Application Hysterosalpingography (HSG) and sonohysterography
Sterilisation Ethylene oxide (EtO), single-use, individually packaged
Marking CE 0051
Presentation Box of 10 units

4. Equivalences and Cross-References

This reference corresponds to the Injector Plus from manufacturer RI.MOS (Italy), whose factory code is the same 730226, packaged in boxes of 10 units. Due to its double-lumen distal balloon design, it occupies the same functional segment as catheter sets for HSG/hysterosonography with balloon from other manufacturers such as CooperSurgical, Argon Medical or Bexen Medical. Within the Cahnos catalogue, it is part of the family of uterine injectors for gynaecological imaging diagnostics alongside other references in the same range.

5. Selection tips and variants of interest

Gauge selection: the Injector Plus of 6 Fr (2.0 mm) offers a balance between insertion rigidity and patient comfort, being especially useful when a guided cervical passage with the stylet is required. If a fully flexible catheter is preferred (greater anatomical adaptation, less trauma), the SOFTINJECTOR of 7 Fr should be considered. For exclusively ultrasound studies of the cavity (sonohysterography) with a smaller gauge, the MININJECTOR of 5 Fr is an alternative, and for completely rigid placement the RIGIDINJECTOR of 6 Fr. In all cases, it is recommended to confirm the contrast medium to be used (water-soluble iodinated for HSG or saline / ultrasound gel for sonohysterography) and verify the compatibility of the Luer-Lock connector with the injection route of the equipment.

Additional information

Manufacturer reference

730226

Product type

Uterine injector for hysterosalpingography (HSG) and sonohysterography

Gauge

6 Fr (2.0 mm outer diameter)

Catheter type

Semi-rigid radiopaque double-lumen

Balloon

Oval distal balloon of thermoplastic rubber, 2.5 cc

Mandrel

Steel, for guided cervical insertion

Connection

Female Luer-Lock

Contents

Catheter, steel stylet, 2.5 cc syringe, stopcock, anti-reflux clamp and rigid introducer with sliding stop

Compatible media

Radiopaque contrast or methylene blue

Sterilisation

Ethylene oxide (EtO), disposable, individually packaged

Certifications

CE 0051

Presentation

Box of 10 units

Application

Hysterosalpingography (HSG) and sonohysterography

Reviews

There are no reviews yet.

Be the first to review “Uterine injector Injector Plus for hysterosalpingography (HSG) – Semi-rigid radiopaque catheter 6 Fr, double-lumen and 2.5 cc balloon (Box of 10 units) | Ref. 730226”

Your email address will not be published. Required fields are marked *