Description
1. Commercial Introduction
The Rigid Hysterographic Catheter PM-CARE® 1V-STD in the large model (Ref. PS2010733) is the solution from the French manufacturer Prince Medical for contrast studies of the uterine cavity in patients with a larger cervical diameter. Its polyurethane foam sealing cone of Ø 25 mm rests against the cervix and ensures a watertight seal throughout the examination, preventing reflux of the contrast medium. A sterile, single-use and latex-free device, designed for gynaecological radiology services, gynaecology clinics and assisted reproduction units.
2. Technical explanation of the equipment and procedure
This catheter is indicated for performing hysterographies (X-rays with contrast medium) and hysterosonographies (ultrasound with physiological saline or saline solution), as well as for evaluating the uterine cavity in fertility studies. It consists of a transparent Pébax catheter, a 1-way stopcock fixed to the body, a rigid polyester handle and a polyurethane foam sealing cone. The foam is positioned against the cervix and acts as an obturator: it prevents contrast reflux and maintains watertightness throughout the examination. Its rigid structure provides stability and atraumatic insertion, while the no-touch insertion technique preserves the sterility of the device. The 7.5 Fr (2.45 mm) calibre is ideal for firmly accessing the cervical canal, and the large variant in the range is distinguished by its larger-diameter foam (25 mm), adapted to wide cervical anatomies.
3. Technical Specifications
Data verified according to the technical data sheet of the manufacturer Prince Medical for reference PS2010733:
| Parameter | Value |
|---|---|
| Type | Rigid single-lumen hysterographic catheter with foam |
| Model | Large (Ø 25 mm foam) |
| Brand / Line | PM-CARE® 1V-STD (Prince Medical) |
| Reference | PS2010733 |
| Number of ways | 1 lumen (1-way stopcock) |
| Catheter diameter | 2.45 mm (7.5 Fr) |
| Foam diameter | 25 mm |
| Length | 330 mm |
| Sealing mechanism | Polyurethane foam sealing cone |
| Materials | Pebax catheter, rigid polyester handle, polyurethane foam |
| Use | Single-use |
| Device class | Is |
| Sterile | Yes |
| Sterilisation method | Ethylene oxide |
| Contains latex | No |
| Shelf life | 5 years |
| Certification | CE |
| Launch date | 2004 |
| Presentation | Box of 5 units in individual sterile packaging |
| Storage | In its original box, in a cool, dry place |
References for the PM-CARE® 1V-STD family (catheters with foam):
| Reference | Model | Foam diameter | Length | Packaging |
|---|---|---|---|---|
| PS1870733 | Small | 15 mm | 330 mm | Box of 5 units |
| PS2010733 | Large | 25 mm | 330 mm | Box of 5 units |
| PS2020733 | Sliding | 15 mm | 340 mm | Box of 5 units |
Comparison of the three 1V-STD variants:
| Characteristic | Small (PS1870733) | Large (PS2010733) | Sliding (PS2020733) |
|---|---|---|---|
| Catheter diameter | 2.45 mm (7.5 Fr) | 2.45 mm (7.5 Fr) | 2.45 mm / 1.5 mm (7.5/4.5 Fr) |
| Foam diameter | 15 mm | 25 mm | 15 mm |
| Length | 330 mm | 330 mm | 340 mm |
| Sliding catheter | No | No | Yes |
4. Equivalences and Cross-References
This catheter belongs to the PM-CARE® family from Prince Medical (French manufacture), available in full in the Cahnos catalogue. Within the same foam sealing range are the small model (PS1870733, 15 mm foam) and the sliding model (PS2020733), which share design, materials and cervical sealing system. As alternatives for cervical sealing in hysterography and hysterosonography, the catalogue offers the malleable 3-way balloon catheter PM-CARE® 3V-BALLOON (ref. PS3310733), indicated when silicone balloon fixation is preferred, and the rigid 2-way vacuum cup catheters PM-CARE® 2V-CUP (refs. PS4292340, PS4292840, PS4293540 and the set PS3460845), comparable to suction cup systems used in gynaecological radiology. To extend the injection route outside the radiological field, the PM-CARE® EXTEND extensions of 20 cm (PS0700002) or 140 cm (PS0700014) can be used. Functionally, the concept of a catheter with a cervical sealing element is equivalent to that of other balloon hysterosalpingography devices on the European market; our technical-commercial team can verify exact calibre and length equivalences according to your protocol.
5. Selection tips and variants of interest
Choose reference PS2010733 (large model) when the patient has a larger cervical diameter or a wide cervical anatomy, common in multiparous women: its 25 mm foam ensures sealing where standard 15 mm cones may be insufficient. For a standard examination with a cervix of usual diameter, opt for the small model (PS1870733); if you need to reach deeper areas of the cavity or adjust the tip during injection, consider the sliding model (PS2020733). If your centre prefers alternative sealing systems, consider the balloon catheter PS3310733 or the vacuum cups from the 2V-CUP range. It is recommended to apply a no-touch insertion technique, not to use the device if the inner packaging is damaged, and to store the box horizontally in a cool, dry place. For large-volume orders or specific needs, consult our technical-commercial team at Cahnos.