Description
1. Commercial Introduction
The Rigid 2-Lumen Hysterographic Catheter with Cup PM-CARE® 2V-CUP (ref. PS4292340) is the reference solution for performing hysterographies, hysterosonographies and methylene blue permeability tests in gynaecology and interventional radiology. Manufactured by Prince Medical, this single-use device combines a vacuum cup of Ø 23 mm, a rigid catheter of 8.5 FR and 400 mm in length, and a dual-lumen system with Luer lock valve that allows the specialist to work with total precision, safety and comfort during gynaecological diagnosis.
2. Technical explanation of the procedure
This catheter is designed for contrast studies of the cervical canal and the uterine cavity. The bell-shaped cup, centred on a core, ensures perfect adhesion of the device to the cervix: the suction function is obtained by applying a progressive vacuum, which guarantees a watertight seal without damaging the tissue. The rigid and malleable manipulator allows the radiologist or gynaecologist to manipulate the uterus to optimise position and access during the examination, while remaining outside the radiological field. The two lumens can be occluded by means of a Luer lock valve and the graduated movable catheter allows contrast injections to be performed at the desired location, facilitating both hysterography (X-rays with contrast) and hysterosonography (ultrasound with saline solution) and methylene blue tests.
3. Technical Specifications
Data verified according to the manufacturer’s technical data sheet for reference PS4292340:
| Parameter | Value |
| Type | Rigid 2-lumen hysterographic catheter with cup |
| Number of ways | 2-way (2 lumens) |
| Catheter diameter | 2.80 mm (8.5 FR) |
| Cup diameter | 23 mm (also available in 28 and 35 mm) |
| Length | 400 mm |
| Single-use | Yes |
| Device class | Is |
| Sterile | Yes |
| Sterilisation method | Ethylene oxide |
| Contains latex | No |
| Shelf life | 5 years |
| Certification | CE |
| Launch date | 2012 |
| Presentation | Box of 5 units in individual sterile packaging |
| Storage | In its original box, in a cool, dry place |
References of the PM-CARE® 2V-CUP family
| Reference | Cup diameter | Packaging |
| PS4292340 | 23 mm | Box of 5 units |
| PS4292840 | 28 mm | Box of 5 units |
| PS4293540 | 35 mm | Box of 5 units |
| PS3460845 | 3 cups (23, 28 and 35 mm) | Box of 5 units |
4. Equivalences and Cross-References
This product belongs to the PM-CARE® 2V-CUP family from the French manufacturer Prince Medical, available in full in the Cahnos catalogue in four references: PS4292340 (cup Ø 23 mm, present), PS4292840 (cup Ø 28 mm), PS4293540 (cup Ø 35 mm) and the set PS3460845 which includes the three cups to cover Ø 20-23, 23-28 and 28-35 mm according to the patient’s morphology. As an alternative sealing method, the range is complemented by the malleable 3-lumen balloon catheter PM-CARE® 3V-BALLOON (ref. PS3310733), indicated when silicone balloon fixation is preferred over a vacuum cup. Functionally, the vacuum cup catheter concept for hysterography/hysterosonography is comparable to cervical sealing devices from international manufacturers commonly used in gynaecological radiology; our technical-commercial team can verify exact calibre and length equivalences according to your protocol.
5. Selection tips and variants of interest
- Cup Ø 23 mm (PS4292340): recommended for small-diameter cervical anatomies and patients with a narrow cervix.
- Cup Ø 28 mm (PS4292840): the intermediate option, the most versatile for the majority of adult patients.
- Cup Ø 35 mm (PS4293540): indicated for larger-diameter cervices, common in multiparous women.
- Set of 3 cups (PS3460845): ideal for radiology and gynaecology departments with varied case mix, as it allows the cup to be chosen according to the patient in the same procedure.
- If your centre prefers a malleable balloon sealing system, consider reference PS3310733 (PM-CARE® 3V-BALLOON, 3-way, 8 FR).
- It is recommended to apply a no-touch insertion technique to preserve sterility and to store the device in a horizontal position, avoiding loads that could damage the cup.





Reviews