Description
1. Introduction
The mini catheter PM-LIFE® IU CH5 with introducer (ref. PS1270500) is the reference disposable solution for assisted reproduction clinics and gynaecology units performing intrauterine inseminations (IUI). Its reduced CH5 calibre (1.65 mm) allows comfortable and atraumatic passage through the cervical canal, while the integrated introducer stabilises and guides the catheter during insertion to achieve safe and reproducible placement in each procedure. Each unit is supplied sterile, in individual packaging, and is latex-free to maximise patient safety.
2. Technical explanation of the procedure
Intrauterine insemination involves depositing a sample of washed and capacitated sperm directly into the uterine cavity, increasing the concentration of spermatozoa in the right place at the time of ovulation. This catheter connects to a syringe or transfer system and advances through the cervical canal into the uterus, guided by the introducer, which provides firmness and stability without trauma. The printed centimetre graduations allow the clinician to control the depth of placement with total precision, while the 1 mm holes located at the 45 mm distal end facilitate the smooth and homogeneous release of the sample. Being a single-use, sterile, Class Is device, it completely eliminates the risk of cross-contamination between procedures and guarantees the optimal biosecurity conditions required in medically assisted reproduction (MAR) techniques.
3. Technical Specifications
| Type | Intrauterine insemination catheter |
| Brand / Range | PM-LIFE® IU |
| Reference | PS1270500 |
| Gauge | CH5 |
| Diameter | 1.65 mm |
| Usable volume | 1.1 ml |
| Length | 175 mm |
| Introducer (insertor) | Yes |
| Mandrel | No |
| Hole diameter | 1 mm |
| Distal end length | 45 mm |
| Centimetric graduations | Yes |
| Single-use | Yes |
| Product class | Is |
| Sterile | Yes |
| Sterilisation method | Gamma radiation |
| Contains latex | No |
| Shelf life | 5 years |
| Certification | CE |
| Launch date | 2002 |
| Presentation | Box of 25 units in individual sterile packaging |
| Storage | In its original box, in a cool, dry place |
4. Equivalences and Cross-References
This PM-LIFE® IU CH5 catheter with introducer (PS1270500) belongs to the brand’s range of intrauterine insemination catheters, which complement each other according to calibre and guiding system:
- PS1260500 – Mini catheter CH5 without introducer or mandrel (Ø 1.65 mm, volume 1.1 ml): most basic option for smaller-calibre cervical canals.
- PS4130500 – Mini catheter CH5 with mandrel (Ø 1.65 mm, volume 1.1 ml): adds a mandrel to pre-form the distal end.
- PS4160500 – Catheter CH5 with introducer and mandrel (Ø 1.65 mm, volume 1.1 ml): variant with both guiding systems.
- PS4160600 – Catheter CH6 with introducer and mandrel (Ø 2 mm, volume 1.6 ml): larger calibre for smoother passage of the sample.
- PS1260600 – Catheter CH6 without introducer or mandrel (Ø 2 mm, volume 1.6 ml).
- PS4130600 – Catheter CH6 with mandrel (Ø 2 mm, volume 1.6 ml).
These catheters are used alongside the brand’s fertility instruments, such as sterile hysterometers for the prior measurement of the uterine cavity, ensuring correct selection of the calibre and insertion length.
5. Selection tips and variants of interest
To choose the appropriate catheter, assess the calibre of the cervical canal and the patient’s uterine morphology. This mini CH5 model with introducer (PS1270500) is especially recommended when firm, stable guidance is desired, useful in anatomies with marked angulations or when the flexible catheter could bend, while maintaining a minimal calibre that minimises discomfort. If the patient has a narrow cervical canal and no additional support is required, the PS1260500 variant (without introducer) offers maximum simplicity. In cases where the distal end also needs to be pre-formed, the CH5 version with introducer and mandrel (PS4160500) or the CH5 with mandrel (PS4130500) are the indicated alternatives; for larger sample volumes, opt for the CH6 variants (PS4160600, PS4130600 or PS1260600). It is recommended to store the boxes in a cool, dry place and to respect the expiry date of each individual sterile package. Consult our technical-commercial team at Cahnos for advice on selection and volume contracting for your centre.





Reviews
There are no reviews yet.