Description
1. Commercial Introduction
The BD Insyte™ Autoguard™ winged peripheral intravenous safety catheter is the reference solution for achieving fast, safe and comfortable peripheral venous access in hospitals, clinics, emergency departments, ICUs and home care. This model in gauge 24G (0.7 × 19 mm) with yellow colour coding and fixation wings integrates BD’s most advanced safety technologies: a button that instantly retracts the needle after puncture, Instaflash™ technology for more successful cannulation on the first attempt, and Vialon™ biomaterial, which reduces complications associated with catheter dwell time. It is supplied in a box of 50 units: request a quote from our technical-commercial department. For large orders you can request a quote.
2. Technical explanation of the device
The BD Insyte™ Autoguard™ catheter is an intravascular (IV) catheter of the over-the-needle type (over needle) designed for short-term peripheral venous access. It incorporates a safety button that, when activated, instantly retracts the needle into the protector, a technology proven to reduce the risk of accidental needlestick injuries (NSI) for healthcare professionals and prevent blood contamination at the time of disposal.
BD Instaflash™ technology incorporates a needle with an additional hole (notch) that allows immediate visualisation of venous return, clinically improving first-attempt insertion success and reducing repeated painful punctures. Meanwhile, the BD Vialon™ biomaterial (biocompatible and radiopaque polyurethane) softens by up to 70% at body temperature inside the vein, allowing longer dwell times and reducing the likelihood of mechanical phlebitis. It is indicated for blood sample collection, blood pressure monitoring and administration of fluids and intravenous medication, and is available with wings (as in this model) for more stable fixation.
3. Technical Specifications
Available references
| Reference | Description | Sales unit |
| GM23908 (SKU Cahnos) | BD Insyte™ Autoguard™ – Winged · BD code: 381912 · Gauge: 24G · Size: 0.7 × 19 mm · Colour: yellow | Box of 50 units |
Product data
| Brand | BD |
|---|---|
| Sales unit | Box of 50 units (box of 50 pcs) |
| Device type | Medical device (Medical device) |
| Device class | II A |
| CND | C0101010202 |
| EAN | 8023279239089 |
Additional technical data
| Manufacturer reference (BD) | 381912 |
|---|---|
| SKU reference Cahnos | 23908 / GM23908 |
| Gauge | 24G |
| Needle size | 0.7 × 19 mm |
| Colour (gauge identification) | Yellow |
| Design | With wings (winged), catheter over needle (over-the-needle) |
| Catheter material | BD Vialon™ (biocompatible and radiopaque polyurethane; softens by up to 70% in the vein) |
| Safety system | Instant needle retraction button (push-button needle shielding) |
| Technology | BD Instaflash™ (needle with additional hole for immediate visualisation of venous return) |
| Intended use | Short-term peripheral venous access: blood collection, blood pressure monitoring and fluid administration |
| Documentation | Multilingual manual and instructions (includes Spanish, ES) |
4. Equivalences and Cross-References
This data sheet corresponds to the BD Insyte™ Autoguard™ winged safety intravenous catheter in its 24G × 19 mm version. The original manufacturer reference is the BD code 381912, which in distribution corresponds to SKU 23908 (Cahnos: GM23908); both codes identify the same item and are complemented by EAN 8023279239089.
There is no validated official equivalence table cross-referencing this specific reference with safety catheters from other manufacturers (e.g. B. Braun, Terumo or Vygon); for any substitution or comparison in tenders, each reference must be checked against the manufacturer’s official technical data sheet, validating gauge, length, material and connection type. Within the Cahnos catalogue there are comparable families by category (not interchangeable 1:1) such as the BD Venflon™ Pro Safety safety catheters (GM23712–GM23714), the BD Venflon™ (GM23715–GM23717), the Terumo Surshield™ Versatus-WP safety catheter (GM37573) and the Terumo Surflo™ range (GM37585, GM37587). Consult our technical-commercial department before substituting any reference.
5. Selection tips and variants of interest
The 24G (yellow) gauge is the usual choice for small-calibre veins: paediatric, geriatric, oncology patients or those with venous fragility, as well as for short-term therapies. If your protocol requires a higher infusion flow rate, consider larger gauges from the same family (22G, 20G or 18G); for very small-calibre access, this 24G is the recommended option.
The with wings (winged) design facilitates a secure grip during puncture and stable catheter fixation, especially useful in patients who mobilise. The Insyte™ Autoguard™ family is available with and without wings depending on professional preference and the centre’s protocol.
The needle protection system with button retraction is a key tool in preventing biological needlestick accidents in the healthcare environment, in line with European regulations on the prevention of sharps injuries (Directive 2010/32/EU). Always check the integrity of the packaging before use, use the catheter for a single cannulation and dispose of it after use in an approved container for sharp healthcare waste.
To order by reference, quote the BD code 381912 or the Cahnos SKU GM23908 (Ref. 23908) and avoid confusion with other gauges or presentations of the family. For volume purchase conditions, supply contracts or tenders, contact our technical-commercial team.