20,91 €

150 cm syringe pump infusion extension line, manufactured in BPA-free medical-grade polyethylene (PE), with male/female Luer Lock connectors with swivel nut. Tubing of Ø1 x 2.5 mm (inner lumen 1.0 mm) ensuring rapid priming and low flow resistance, ideal for continuous infusions and drug administration with standard syringe pumps on the market. Compatible with syringes, three-way stopcocks and vascular access systems. Presentation in a box of 50 units. Ref. PMFPS150PE001.

International shipping. Import duties and taxes are payable by the recipient.

Reference
PMFPS150PE001

Description

1. Introduction

The 150 cm syringe pump infusion extension line is designed to optimise mobility and connectivity in critical medical environments. Its medical-grade polyethylene (PE) construction ensures a reliable connection between the syringe loaded in the pump and the patient’s vascular access, maintaining the circuit’s leak-tightness throughout the therapy. It is the ideal solution for hospitalisation units, ICU, paediatrics, emergency and oncology departments that need to keep the pump away from the patient without compromising infusion accuracy or safety.

2. Technical explanation of the equipment

This single-lumen extension line is inserted between the syringe mounted on the pump and the patient’s access point, allowing the distance and patient mobility to be increased without disconnecting the circuit. The male and female Luer Lock connectors of the rotating type (swivel nut) ensure a secure threaded coupling that prevents accidental disconnections and leaks during infusion, without transmitting torque to the tubing. The polyethylene tubing combines a 1.0 mm inner lumen —which reduces flow resistance and facilitates rapid priming— with a 2.5 mm outer diameter that provides the necessary rigidity to withstand passage through the pump’s clamp without collapsing. Being BPA-free, it is suitable for use with drugs and solutions in demanding clinical environments.

3. Technical Specifications

Reference PMFPS150PE001
Product type 1-way infusion extension line for syringe pump
Length 150 cm
Tube diameter Ø1 x 2.5 mm (internal Ø 1.0 mm / external Ø 2.5 mm)
Proximal connector Female Luer Lock (rotating)
Distal connector Male Luer Lock (rotating)
Material Medical-grade polyethylene (PE)
Composition BPA-free
Approximate priming volume ≈ 1.2 ml (estimated based on inner diameter and length)
Compatibility Syringe pumps and standard syringes with Luer Lock connection
Presentation Box of 50 units

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer for this reference; the following comparisons are provided for guidance only and must be confirmed with the technical department before use in tenders or stock replacement.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Cahnos PE 150 cm extension line with swivel Luer Lock PMFPS150PE001 (current product) Reference product PE, Ø1 x 2.5 mm, box of 50 units
B. Braun Original Perfusor® Line PE, 150 cm 8722935 Comparable by category, not interchangeable 1:1 PVC-free PE, male/female Luer Lock, 150 cm; differs in Ø 1.0 x 2.0 mm and priming volume of 1.27 ml; declared max. pressure of 2 bar; box of 100 units
Vygon Lectro-Cath polyethylene (PE), 150 cm 1155.15 Comparable by category, not interchangeable 1:1 PE, female/male Luer Lock, 150 cm, Ø 1.0 x 2.0 mm, priming volume 1.5 ml, with colour-coded clip; box of 50 units

Within the Cahnos catalogue, this extension line shares a family with the 25, 50 and 200 cm PE versions (PMFPS25PE001, PMFPS50PE001, PMFPS200PE001) and with the PVC versions of Ø1 x 2.5 mm and Ø1.5 x 2.5 mm (PMFMPS150D1F, PMFMPS150F), comparable in function but with different material and diameter.

5. Selection tips and variants of interest

  • Length: the 150 cm version balances patient mobility and reduced priming volume. For shorter lines, consider the 25 or 50 cm versions; for greater distance, the 200 cm version of the same PE family.
  • Material: if your protocol requires avoiding PVC or plasticisers, this BPA-free polyethylene (PE) line is the appropriate option; for photosensitive drugs, consider the opaque PVC extension lines.
  • Connector: the swivel nut facilitates threading without transmitting torque to the tubing; if you prefer rigid fixation, consult the versions with fixed Luer Lock.
  • Accessories: combine it with three-way stopcocks and other infusion accessories from the catalogue to adapt the circuit to each therapy.

For tenders or replacement of references from other manufacturers, contact our technical-commercial department to validate exact compatibility and request samples.

Additional information

Reference

PMFPS150PE001

Product type

1-way infusion extension line for syringe pump

Tube diameter

Ø1 x 2.5 mm (internal Ø 1.0 mm / external Ø 2.5 mm)

Proximal connector

Female Luer Lock (rotating)

Distal connector

Male Luer Lock (rotating)

Material

Medical-grade polyethylene (PE)

Composition

BPA-free

Priming volume

≈ 1.2 ml (estimated)

Compatibility

Syringe pumps and standard syringes with Luer Lock connection

Presentation

Box of 50 units

Longitud

150 cm

Reviews

There are no reviews yet.

Be the first to review “Infusion Extension Line for Syringe Pump 150 cm | PE Male/Female Swivel Luer Lock BPA-free | Ref. PMFPS150PE001”

Your email address will not be published. Required fields are marked *