Description
1. Introduction
The 150 cm infusion extension line for syringe pumps (Ref. PMFMPS150F, SKU 0322027) is the essential accessory to complete the infusion circuit between the syringe loaded in the pump and the patient’s vascular access, increasing distance and mobility without compromising administration accuracy. Made from BPA-free medical-grade PVC, it provides a secure, leak-proof and reliable connection throughout the therapy.
It is the indicated solution for hospitals, ICUs, emergency departments, oncology and paediatrics that need a robust, single-use drug administration circuit with immediate availability from stock. Price per box of 300 units.
2. Technical explanation of the equipment and procedure
This single-lumen extension line is placed between the syringe mounted on the pump and the patient’s access point, allowing the pumping device to be moved away when the clinical situation requires it, without disconnecting the infusion. The male and female Luer Lock connectors of the rotating type (swivel nut) ensure a secure threaded coupling without transmitting torque to the tubing, preventing accidental disconnections, leaks and kinking during drug administration, even with patient movement.
The Ø1.5×2.5 mm tubing combines a 1.5 mm inner lumen —offering low flow resistance and rapid priming— with a 2.5 mm outer diameter that provides the necessary rigidity to withstand passage through the pump’s clamp without collapsing. Being BPA-free, it is suitable for use with drugs and solutions in demanding clinical environments, ensuring a constant, unobstructed flow during continuous, intermittent and precision infusions with syringe pumps.
3. Technical Specifications
| Reference | PMFMPS150F (SKU 0322027) |
| Product type | 1-way infusion extension line for syringe pump |
| Length | 150 cm |
| Tube diameter | Ø1.5 × 2.5 mm (Ø inner 1.5 mm / Ø outer 2.5 mm) |
| Proximal connector | Female Luer Lock (rotating collar) |
| Distal connector | Male Luer Lock (rotating collar) |
| Material | Medical-grade PVC |
| Composition | BPA-free |
| Approximate priming volume | ≈ 2.6 ml (estimated based on inner lumen and length; the manufacturer does not declare an official value) |
| Compatibility | Syringe pumps and standard syringes with Luer Lock connection |
| Use | Single-use (disposable) |
| Sterility | Not specified (consult technical department) |
| Presentation | Box of 300 units |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references this specific reference with other brands; the following comparisons are offered for guidance only (category level) and must be confirmed with the Cahnos technical department before use in tenders or stock replacement. Field by field, the length (150 cm), the Luer Lock male/female connection and the inner diameter (1.5 mm) match the standard syringe pump lines on the market, but the outer diameter, priming volume and maximum pressure declared by other manufacturers differ, so they are not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos | PVC extension line 150 cm Rotating Luer Lock Ø1.5×2.5 mm | PMFMPS150F (0322027) | Reference product | BPA-free PVC, Ø1.5 × 2.5 mm, swivel nut, box of 300 units |
| Cahnos | PVC extension line 150 cm Fixed Luer Lock Ø1.5×2.5 mm | PMFPS150F (0322011) | Same family, connector variant | Same length and diameter, but with fixed nut; box of 125 units |
| Cahnos | PVC extension line 150 cm Rotating Luer Lock Ø1×2.5 mm | PMFMPS150D1F | Same family, diameter variant | Microbore tube of Ø1 mm inner; lower priming volume (≈1.2 ml) |
| B. Braun | Original Perfusor® Line PVC, 150 cm | 8722960 | Comparable by category, not interchangeable 1:1 | PVC, Luer Lock male/female, 150 cm; differs in Ø1.5 × 2.7 mm, priming volume 2.73 ml and declared max. pressure of 2.0 bar; pack of 100 units |
| B. Braun | Original Perfusor® Line Opaque PVC, 150 cm | 8722919 | Comparable by category, not interchangeable 1:1 | Opaque PVC for photosensitive drugs; Ø1.5 × 2.7 mm, priming volume ≈2.65 ml; pack of 100 units |
| B. Braun | Original Perfusor® Line PE, 150 cm | 8722935 | Comparable by category, not interchangeable 1:1 | Polyethylene (not PVC), Ø1.0 × 2.0 mm, priming volume 1.27 ml, max. pressure 2.0 bar; pack of 100 units |
| Vygon | LectroCath (polyethylene extension line), 150 cm | Series 1155.xx (e.g. 1155.15) | Comparable by category, not interchangeable 1:1 | Polyethylene, Luer Lock female/male, Ø1.0 × 2.0 mm, colour-coded clip; confirm exact reference according to presentation |
| Fresenius Kabi | Injectomat® line for syringe pump, 150 cm | Code to be confirmed with the manufacturer | Pending confirmation | Verify tubing diameter and connector configuration against the manufacturer’s official technical data sheet |
Within the Cahnos catalogue, the PMFMPS_F series shares material (BPA-free PVC), inner lumen (Ø1.5 mm) and connector (rotating Luer Lock male/female), differing only in length: PMFMPS25F (25 cm), PMFMPS50F (50 cm), PMFMPS100F (100 cm), PMFMPS150F (150 cm) and PMFMPS200F (200 cm). They are interchangeable in performance by choosing the length according to the application. The D1F series offers microbore tubing Ø1 × 2.5 mm (lower residual volume) and the PE series uses PVC-free polyethylene.
5. Selection tips and variants of interest
- Length: the 150 cm version offers a good balance between patient mobility and contained priming volume; for shorter circuits consider the 25, 50 or 100 cm versions and for greater distance the 200 cm version from the same family.
- Connector: the swivel nut facilitates threading without transmitting torque to the tubing; if you prefer a rigid fixation without rotation, consult the version with fixed Luer Lock (PMFPS150F).
- Diameter: the tubing with 1.5 mm inner diameter offers good flow rate and rapid priming; if your protocol requires minimising residual volume (high-risk medication), consider the microbore series of Ø1 mm (PMFMPS150D1F).
- Material: if your protocol requires avoiding PVC or plasticisers, the polyethylene line (PMFPS150PE001) is the natural alternative; for photosensitive drugs, consult the opaque PVC version (PMFTJPS150F).
- Compatibility: always verify the pump, syringe and three-way stopcocks in the circuit; this extension line is compatible with standard syringes and syringe pumps with Luer Lock connection on the market.
- Accessories: combine it with three-way stopcocks, non-return valves, obturators and other infusion accessories from the Cahnos catalogue to adapt the circuit to each therapy.
For tenders or replacement of references from other manufacturers, contact our technical-commercial department to validate exact compatibility and request samples before institutional purchase.