Description
1. Introduction
The infusion extension line for syringe pump PMFMPS100F is the reference accessory for completing infusion circuits in hospitalisation, ICU and critical care services. With 100 cm length and rotating male/female Luer Lock connectors, it allows the pump to be moved away from the patient with total freedom of movement, maintaining a leak-proof, safe and unobstructed connection throughout the treatment.
Made from BPA-free medical-grade PVC, it guarantees compatibility with virtually all syringe pumps and infusion systems on the market. It is supplied in a box of 125 units, making it a cost-effective and reliable replacement solution for hospital purchasing and public tenders.
2. Technical Explanation
This extension line acts as an extension line between the syringe loaded in the pump and the patient’s catheter or vascular access. Its flexible tubing of gauge Ø1.5×2.5 mm (1.5 mm inner diameter and 2.5 mm outer diameter) provides a stable and continuous flow, suitable for the low and medium flow rates typical of syringe pumps.
The rotating Luer Lock (swivel nut) present at both ends allows the connection to be secured by threading, preventing accidental disconnections, while the free rotation of the collar prevents the tubing from twisting or kinking when the patient or pump moves. Being BPA-free, it is suitable for the administration of drugs and solutions in demanding clinical environments, minimising the risk of interactions with the material.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference | PMFMPS100F |
| Product type | 1-way infusion extension line for syringe pump |
| Length | 100 cm |
| Tube diameter | Ø1.5 x 2.5 mm (internal Ø 1.5 mm / external Ø 2.5 mm) |
| Proximal connector | Female Luer Lock (rotating collar) |
| Distal connector | Male Luer Lock (rotating collar) |
| Material | Medical-grade PVC |
| Composition | BPA-free |
| Approximate priming volume | ≈ 1.8 ml (estimated based on inner diameter and length; the manufacturer does not declare an official value) |
| Maximum pressure | Not declared by the manufacturer |
| Compatibility | Syringe pumps and standard syringes with Luer Lock connection |
| Use | Single-use |
| Sterility | Not specified (consult technical department) |
| Presentation | Box of 125 units |
4. Equivalences and Cross-References
There is no cross-reference equivalence table validated by the manufacturer for this reference against other brands; the following comparisons are provided for guidance only and must be confirmed with the Cahnos technical department before use in tenders or stock replacement.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos | PVC Extension Line 100 cm Rotating Luer Lock Ø1.5×2.5 | PMFMPS100F (current product) | Reference product | BPA-free PVC, Ø1.5 x 2.5 mm, swivel nut, box of 125 units |
| B. Braun | Original Perfusor® Line PVC Standard, 100 cm, 1.5×2.7 mm | 0009483H (B. Braun catalogue) | Comparable by category, not interchangeable 1:1 | PVC, Luer Lock, inner Ø 1.5 mm and outer 2.7 mm, pressure <2 bar, pack of 100 units |
| B. Braun | Original Perfusor® Line PE, 100 cm | 8255067 (B. Braun catalogue) | Comparable by category, not interchangeable 1:1 | Polyethylene, Ø1.0 x 2.0 mm, priming volume 0.88 ml, max. pressure 2 bar |
| Codan | Syringe Pump Extension Set, 100 cm (microbore) | 71.4356 (Codan catalogue) | Comparable by category, not interchangeable 1:1 | PVC, internal diameter 0.9 mm, micro male/female Luer Lock, sliding clamp |
| Vygon | V-Green PE Extension Line, 100 cm | Code to be confirmed with the manufacturer | Pending confirmation | Polyethylene, Ø1.0 x 2.0 mm, priming volume ~1.2 ml, pack of 50 units |
| Fresenius Kabi | Injectomat® line for syringe pump | Code to be confirmed with the manufacturer | Pending confirmation | Check tubing diameter and connector configuration against the official technical data sheet |
Within the Cahnos catalogue, the PMFMPS_F series shares material (BPA-free PVC), inner lumen (Ø1.5 mm) and connector (rotating male/female Luer Lock), differing only in length: PMFMPS25F (25 cm), PMFMPS50F (50 cm), PMFMPS100F (100 cm), PMFMPS150F (150 cm) and PMFMPS200F (200 cm). They are interchangeable in performance by choosing the length according to the application.
Not verified: there is no cross-reference table validated by the manufacturer against other brands; it is recommended to consult the Cahnos technical department before finalising the substitution in public procurement specifications.
5. Selection tips and variants of interest
- Length: the 100 cm version offers a good balance between patient mobility and contained priming volume. For shorter circuits, consider the 25 or 50 cm versions; for greater distance, the 150 or 200 cm versions of the same family.
- Diameter: if your protocol requires minimising residual volume and priming, the D1F series with Ø1 x 2.5 mm tubing (e.g. PMFMPS100D1F) is the most precise option; if you require higher flow rate, this series with Ø1.5 x 2.5 mm is the appropriate one.
- Connector: the rotating nut facilitates threading without transmitting torsion to the tubing; if you prefer a rigid fixation without rotation, consult the versions with fixed Luer Lock (PMFPS_F series, e.g. PMFPS100F).
- Material: if your protocol requires avoiding PVC or plasticisers, consider the polyethylene lines (PMFPS_PE001 series) available in the Cahnos infusion catalogue.
- Accessories: combine it with three-way stopcocks, non-return valves and other infusion accessories from the catalogue to adapt the circuit to each therapy.
- For tenders or replacement of references from other manufacturers, contact our technical-commercial department to validate exact compatibility and request samples.