Description
1. Introduction
The 100 cm syringe pump infusion extension line (Ref. PMFPS100F) is the essential replacement accessory for completing infusion circuits in hospitalisation, ICU, emergency, oncology and paediatrics departments. With a length of 100 cm and fixed male/female Luer Lock connectors, it allows the pump to be positioned away from the patient with freedom of movement, maintaining a leak-proof, secure and drip-free connection throughout the therapy.
Made from BPA-free medical-grade PVC, it combines flexibility, precision and universal compatibility. It is supplied in a box of 125 units, making it the cost-effective and reliable replacement solution for hospital purchasing, ward stock and public tenders, with immediate dispatch from warehouse.
2. Technical explanation of the equipment and procedure
This extension line acts as an extension of the line between the syringe loaded in the pump and the patient’s catheter or vascular access, extending the circuit without having to disconnect the infusion. Its flexible tube of gauge Ø1.5 x 2.5 mm (1.5 mm internal diameter and 2.5 mm external diameter) provides a stable and continuous flow, suitable for the low and medium flow rates typical of syringe pumps, with low resistance to drug passage and rapid priming.
The fixed Luer Lock on both ends (distal male and proximal female) ensures a rigid screw fixation, with no moving parts that could loosen, preventing accidental disconnections and leaks during drug administration. Being BPA-free and single-use, it is suitable for the administration of drugs and solutions in demanding clinical environments, minimising the risk of interactions with the material.
3. Technical Specifications
| Characteristic | Specification |
| Reference | PMFPS100F |
| Product type | 1-way infusion extension line for syringe pump |
| Length | 100 cm |
| Tube diameter | Ø1.5 x 2.5 mm (internal Ø 1.5 mm / external Ø 2.5 mm) |
| Proximal connector | Female Luer Lock (fixed) |
| Distal connector | Male Luer Lock (fixed) |
| Material | Medical-grade PVC |
| Composition | BPA-free |
| Approximate priming volume | ≈ 1.8 ml (estimated based on internal diameter and length; the manufacturer does not declare an official value) |
| Maximum pressure | Not declared by the manufacturer |
| Compatibility | Syringe pumps and standard syringes with Luer Lock connection |
| Use | Single-use (disposable) |
| Sterility | Not specified (consult technical department) |
| Presentation | Box of 125 units |
4. Equivalences and Cross-References
There is no cross-reference equivalence table validated by the manufacturer for this reference against other brands; the following comparisons are provided for guidance only and must be confirmed with the Cahnos technical department before use in tenders or stock replacement. Field by field, the length (100 cm), the male/female Luer Lock connection and the internal diameter (1.5 mm) match the standard syringe pump lines on the market, but the external diameter, priming volume and maximum pressure declared by other manufacturers differ, so they are not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos | PVC extension line 100 cm fixed Luer Lock Ø1.5×2.5 | PMFPS100F (current product) | Reference product | BPA-free PVC, Ø1.5 x 2.5 mm, fixed nut, box of 125 units |
| B. Braun | Original Perfusor® Line PVC Standard, 100 cm, 1.5 x 2.7 mm | 0009483H (B. Braun catalogue) | Comparable by category, not interchangeable 1:1 | PVC, Luer Lock, internal Ø 1.5 mm and external 2.7 mm, priming volume 1.84 ml, max. pressure 2.0 bar, pack of 100 units |
| B. Braun | Original Perfusor® Line PE, Luer Lock, 100 cm | 8255067 (B. Braun catalogue) | Comparable by category, not interchangeable 1:1 | Polyethylene (not PVC), Ø1.0 x 2.0 mm, priming volume 0.88 ml, max. pressure <2 bar, pack of 100 units |
| Codan | Syringe Pump Extension Set, 100 cm (microbore) | 71.4356 (Codan catalogue) | Comparable by category, not interchangeable 1:1 | PVC, internal diameter 0.9 mm, micro male/female Luer Lock, sliding clamp |
| Fresenius Kabi | Injectomat® line for syringe pump, 100 cm | Code to be confirmed with the manufacturer | Pending confirmation | Verify tubing diameter and connector configuration against the manufacturer’s official technical data sheet |
| Vygon | PE extension line for syringe pump, 100 cm | Code to be confirmed with the manufacturer | Pending confirmation | Verify exact reference and measurements (the PE versions of the range use Ø1.0 x 2.0 mm) |
Within the Cahnos catalogue, the PMFPS_F series shares material (BPA-free PVC), internal diameter (Ø1.5 mm) and connector (fixed male/female Luer Lock), differing only in length: PMFPS25F (25 cm), PMFPS50F (50 cm), PMFPS100F (100 cm), PMFPS150F (150 cm) and PMFPS200F (200 cm). They are interchangeable in performance by choosing the length according to the application. The PMFMPS_F series (e.g. PMFMPS100F) maintains the same tube and material but with a rotating nut Luer Lock; the D1F series offers microbore tube Ø1 x 2.5 mm (lower residual volume) and the PE series uses PVC-free polyethylene.
Not verified: there is no cross-reference table validated by the manufacturer against other brands; it is recommended to consult the Cahnos technical department before fixing the substitution in public procurement specifications.
5. Selection tips and variants of interest
Length: the 100 cm version offers a good balance between patient mobility and contained priming volume. For shorter circuits, consider the 25 or 50 cm versions; for greater distance, the 150 or 200 cm versions of the same PMFPS_F series.
Connector: the fixed nut provides a rigid fixation without rotation; if you prefer a thread that does not transmit torsion to the tube during patient movements, consult the series with rotating Luer Lock (PMFMPS_F, e.g. PMFMPS100F).
Diameter: the Ø1.5 x 2.5 mm tube offers good flow and rapid priming; if your protocol requires minimising residual volume and priming (high-risk medication), consider the D1F series with Ø1 x 2.5 mm tube (e.g. PMFMPS100D1F).
Material: if your protocol requires avoiding PVC or plasticisers, consider the polyethylene lines (PMFPS_PE001 series) available in the Cahnos infusion catalogue; for photosensitive drugs, consult the opaque PVC extension lines.
Compatibility: always verify the pump, syringe and three-way stopcocks in the circuit; this extension line is compatible with standard syringes and syringe pumps with Luer Lock connection on the market.
Accessories: combine it with three-way stopcocks, non-return valves, obturators and other infusion accessories from the Cahnos catalogue to adapt the circuit to each therapy.
For tenders or replacement of references from other manufacturers, contact our technical-commercial department to validate exact compatibility and request samples before institutional purchase.