Description
1. Rapid, precise infusion without electronic equipment
The Elastomeric Infusion Pump ELASPUMP® 60 ml (Ref. 093001/30) is the continuous high-flow solution designed to deliver the full elastomer volume at a constant flow rate of 30 ml/hour, which equates to an approximate duration of 0 days + 2 hours at full volume. It is the ideal choice for intravenous antibiotic therapy, chemotherapy and other treatments requiring rapid, precise and controlled infusion in hospitals, clinics, home hospitalisation units and outpatient care centres.
As it does not depend on batteries or electrical sources, it offers a very competitive cost per treatment, eliminates the risk of cross-contamination between patients and simplifies service logistics, as it requires no maintenance or calibration by healthcare staff.
2. Technical description and operating principle
The ELASPUMP® pump consists of a silicone elastomer contained within a sealed, rigid and transparent housing, which prevents accidental leaks and allows visual inspection of the drug level from the outside without having to open the device. Its operating principle is based on the elastic recovery pressure of the elastomer, which drives the medication through the tubular system at a constant, factory-calibrated flow rate (30 ml/h), ensuring a continuous and homogeneous infusion throughout administration.
Key technical features:
- One-way filling valve with closed circuit and flat bottom, compatible with standard syringes, facilitating elastomer loading.
- Hydrophobic filter on the male luer-lock connector cap, allowing the tubular system to be primed without removing the cap, preserving internal sterility until actual use.
- In-line particle filter, which retains impurities and guarantees the purity of the administered drug.
- Removable sliding clamp, easy to remove if necessary.
- Flexible, anti-kink tubing (anti-kink), with distal luer-lock connection and DEHP- and PVC-free line.
- Colour-coded label with flow rate printing, for immediate flow identification by the patient and healthcare professional.
- Patient label, designed for easy treatment personalisation.
- Printed graduation scale to follow the course of the infusion and full traceability: variable data and product code printed on the external housing and on the pump body.
3. Technical Specifications
The main technical specifications of the ELASPUMP® 60 ml continuous high-flow pump at 30 ml/hour are detailed below:
| Brand | ELASPUMP® |
| Reference | 093001/30 |
| Capacity | 60 ml |
| Flow type | Fixed continuous high flow (factory-calibrated) |
| Infusion flow rate | 30 ml/hora |
| Approximate duration | 0 days + 2 hours (approx. 120 minutes at full volume) |
| Drive mechanism | Silicone elastomer in rigid and transparent casing |
| Filling system | Closed-circuit one-way valve, compatible with standard syringe |
| Connection | Male Luer-Lock connector with cap and hydrophobic filter |
| Filtration | Hydrophobic filter + in-line particle filter |
| Infusion line | Flexible anti-kink tubing (anti-kink), DEHP- and PVC-free |
| Routes of administration | Intravenous, arterial, epidural and subcutaneous |
| Clinical indications | Antibiotic therapy, chemotherapy, pain therapy and antiviral treatments |
| Power supply | Does not require battery or electrical power source |
| Use | Single-use, sterile (individual rigid blister) |
| Composition | DEHP-free, PVC-free and latex-free · biocompatible |
| Regulatory standard | Medical device compliant with Regulation (EU) 2017/745 (MDR) · CE marking |
Indicative infusion duration according to flow rate (60 ml volume):
| Flow rate | Approximate duration |
| 30 ml/hour (current product) | 0 days + 2 hours (approx. 120 minutes) |
| 60 ml/hora | 0 days + 1 hour (approx. 60 minutes) |
| 120 ml/hora | 0 days + ½ hour (approx. 30 minutes) |
ELASPUMP® continuous high-flow range available at Cahnos:
| Reference | Capacity | Flow rate | Approximate duration |
| 093001/30 (current product) | 60 ml | 30 ml/hora | 0 days + 2 hours |
| 093001/60 | 60 ml | 60 ml/hora | 0 days + 1 hour |
| 093001/120 | 60 ml | 120 ml/hora | 0 days + ½ hour |
| 093002/100 | 100 ml | 100 ml/hora | 0 days + 1 hour |
| 093002/200 | 100 ml | 200 ml/hora | 0 days + ½ hour |
| 093005/125 | 275 ml | 125 ml/hora | 0 days + 2 hours |
| 093005/250 | 275 ml | 250 ml/hora | 0 days + 1 hour |
Indicative values calculated at full volume; actual duration may vary slightly depending on usage conditions and drug characteristics.
4. Equivalences and Cross-References
The ELASPUMP® 60 ml continuous high-flow (Ref. 093001/30) belongs to the high-flow elastomeric pump range of the ELASPUMP® family and is complementary to the following references available at Cahnos:
- 093001/60: ELASPUMP® 60 ml, continuous high flow 60 ml/h (0 days + 1 hour), DEHP-free.
- 093001/120: ELASPUMP® 60 ml, continuous high flow 120 ml/h (0 days + ½ hour), DEHP-free.
- 093002/100 and 093002/200: ELASPUMP® 100 ml high flow (100 and 200 ml/h) for larger volumes.
- 093005/125 and 093005/250: ELASPUMP® 275 ml high flow (125 and 250 ml/h) for longer-duration therapies.
- 093001/M1 · M2 · M3: ELASPUMP® 60 ml variable flow, for protocols with adjustable flow rate.
There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; consult the technical department before use in tenders. However, due to its pressurised elastomer system with luer-lock connector, hydrophobic filter and fixed factory-calibrated flow rate, this device is comparable at category level with disposable high-flow rapid-infusion elastomeric pumps from other manufacturers in the sector (families such as Nipro Surefuser®+ or the high-flow elastomeric infusers from Pinmed and similar used in outpatient antibiotic therapy). As this is a functional comparison and not a 1:1 equivalence, the exact flow rate, nominal volume, connection type and infusion duration must be verified in each manufacturer’s technical data sheet before any substitution in a clinical protocol.
5. Selection tips and variants of interest
- Volume and duration: this 60 ml version at 30 ml/h is designed for infusions that must be completed in approximately 2 hours, very useful in rapid antibiotic therapy schedules programmed by shift.
- Required flow rate: if you need even faster delivery, consider references 093001/60 (1 hour) and 093001/120 (half an hour). If you need to extend administration with the same volume, choose the lower flow rates in the 60 ml range (continuous flow from 1 to 10 ml/h).
- Volume to infuse: for doses above 60 ml with rapid infusion, the 100 ml versions (Refs. 093002/100 and 093002/200) and 275 ml versions (Refs. 093005/125 and 093005/250) are available.
- Adjustable protocols: if the flow rate needs to be modified during treatment, consider the variable-flow 60 ml versions (Refs. 093001/M1, M2 and M3), with 4 or 8 speeds.
- Photosensitive drugs: for light-sensitive medication, select the ELASPUMP® versions with UV protection (e.g., Refs. 093002/5/B and 093005/8/B).
- Accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.
- Purchasing conditions: contact our technical-commercial department to request samples, technical data sheets or special conditions for tenders and hospital procurement.







Reviews