Description
1. Continuous, safe infusion without electronic equipment
The elastomeric infusion pump ELASPUMP® of 275 ml with UV protection is the ideal solution for the continuous administration of drugs in hospitals, clinics, home hospitalisation units and outpatient care centres. As it does not depend on batteries, electricity or maintenance, it offers a very competitive cost per treatment and eliminates the risk of cross-contamination between patients. Its UV protection makes it especially recommended for photosensitive drugs, common in oncology therapies.
2. Technical description of the device
The ELASPUMP® pump is composed of a silicone elastomer housed inside a hermetic, rigid and transparent casing with UV protection, which prevents accidental leaks and allows visual inspection of the drug level from the outside without having to open the device. The operating principle is based on the elastic recovery pressure of the elastomer, which drives the medication through the tubular system at a constant flow rate calibrated in the factory of 2.5 ml/hour, ensuring a homogeneous infusion for approximately 4 days and 14 hours of autonomy.
- One-way filling valve with a closed circuit and flat bottom, which facilitates loading of the elastomer using a standard syringe.
- Hydrophobic filter on the capsule of the male luer-lock connector, which allows priming of the tubular system without removing the capsule, preserving internal sterility until actual use.
- In-line particle filter that retains impurities and guarantees the purity of the administered drug.
- Removable sliding clamp, easy to remove when necessary.
- Colour-coded label with flow rate printing for quick and immediate identification of the flow.
- Patient label for easy treatment customisation.
- Full traceability: variable data and product code printed on the external casing and on the pump body.
3. Technical Specifications
| Characteristic | Specification |
| Brand | ELASPUMP® |
| Reference | 093005/41/B |
| Capacity | 275 ml |
| Flow type | Fixed continuous (factory-calibrated) |
| Infusion flow rate | 2.5 ml/hora |
| Approximate duration | ≈ 4 days + 14 hours (at full volume) |
| Protection | UV protection for photosensitive drugs |
| Drive mechanism | Silicone elastomer in rigid and transparent casing |
| Filling system | Closed-circuit one-way valve, compatible with standard syringe |
| Connection | Male Luer-lock with cap and hydrophobic filter |
| Filtration | Hydrophobic filter + in-line particle filter |
| Routes of administration | Intravenous, arterial, epidural and subcutaneous |
| Clinical indications | Chemotherapy, pain therapy, antiviral and antibiotic treatments |
| Power supply | Does not require battery or electrical power source |
| Use | Single-use, sterile |
| Composition | DEHP-free, PVC-free, latex-free |
| Presentation | Sterile unit |
Indicative duration of the ELASPUMP® range of 275 ml with UV protection:
| Reference | Flow rate | Approximate duration |
| 093005/2/B | 1 ml/h (continuous, UV) | 11 days + 11 hours |
| 093005/4/B | 2 ml/h (continuous, UV) | 5 days + 17 hours |
| 093005/41/B (current product) | 2.5 ml/h (continuous, UV) | 4 days + 14 hours |
| 093005/5/B | 4 ml/h (continuous, UV) | 2 days + 21 hours |
| 093005/6/B | 5 ml/h (continuous, UV) | 2 days + 7 hours |
| 093005/65/B | 7 ml/h (continuous, UV) | 1 day + 15 hours |
| 093005/7/B | 8 ml/h (continuous, UV) | 1 day + 10 hours |
| 093005/8/B | 10 ml/h (continuous, UV) | 1 day + 3 hours |
Indicative values calculated at full volume; actual duration may vary slightly depending on usage conditions and drug characteristics.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The ELASPUMP® 275 ml with UV protection (Ref. 093005/41/B) belongs to the family of disposable elastomeric continuous-flow pumps used in ambulatory infusion, patient-controlled analgesia and home intravenous therapy. Due to its 275 ml capacity, its pressurised silicone elastomer, its luer-lock connector, its fixed calibrated flow rate and its UV protection, it is comparable at category level (not interchangeable 1:1) with continuous infusion elastomeric systems from other leading brands on the market, such as the range of disposable elastomeric pumps from Baxter, the portable elastomeric infusion devices from Nipro (type Neofuser/Surefuser), the elastomeric pumps from MedFuser, the SMARTeZ systems and Easyflow-type elastomeric infusion pumps. 1:1 interchangeability must be confirmed by comparing capacity, flow rate, material, connection and accessories in the official technical data sheet of each manufacturer before use in clinical protocols.
5. Selection tips and variants of interest
- Volume to be infused: the 275 ml version is ideal for long-duration therapies (≈ 4 days and 14 hours at 2.5 ml/h). For smaller volumes, versions of 60 ml (Ref. 093001/4) and 100 ml (Ref. 093002/5/B) are available.
- Required flow rate: if your protocol is fixed and prolonged, this continuous flow model at 2.5 ml/h offers an economical and reliable solution. If you need to adjust the speed during treatment, consider the variable flow versions of 275 ml (Refs. 093005/M1, M2 and M3).
- Photosensitive drugs: for light-sensitive medications, always choose the ELASPUMP® versions with UV protection (Refs. 093005/2/B, 093005/4/B, 093005/41/B, 093005/5/B, 093005/65/B, 093005/7/B and 093005/8/B).
- Rapid infusions: if you need to administer the volume in a short time, consider the high continuous flow versions of 275 ml (Refs. 093005/125 and 093005/250).
- Recommended accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.
Contact our technical-commercial department to request samples, technical data sheets or special conditions for tenders and hospital purchases.







Reviews
There are no reviews yet.