Description
Safety blood lancet “Safety” 18G green – Safe capillary puncture for paediatrics
The sterile “Safety” safety blood lancet 18G 1.8 mm (ref. 1110118) is the reference solution for obtaining capillary blood micro-samples in paediatric patients. Its green colour code immediately identifies the version indicated for paediatric heel, facilitating rapid selection of the appropriate device in clinics, neonatology units, hospitals and clinical analysis laboratories. A single-use, sterile product with an integrated safety mechanism, designed to protect the professional and care for the smallest patient.
How does it work and why is it safe?
Capillary puncture of the heel is the standard method for neonatal screening and low-volume blood tests in infants, as it allows the required blood drop to be obtained with minimal trauma. This lancet is activated by simple pressure against the puncture site, without the need for prior cocking or additional steps: simply remove the sterility cap, place the device on the clean heel and press. The ultra-sharp needle, coated with silicone to facilitate penetration, remains hidden before and after use thanks to the closed housing and the irreversible automatic retraction mechanism. This system minimises the risk of accidental needlestick injuries and cross-contamination, and prevents reuse of the device, ensuring traceability and hygiene of the procedure.
Technical specifications
| Characteristic | Value |
|---|---|
| Reference | 1110118 |
| Product type | Safety blood lancet, single-use |
| Needle gauge | 18G |
| Puncture depth | 1.8 mm |
| Indication | Paediatric heel and neonatal screening |
| Identification colour | Green |
| Sterility | Yes, sterile (gamma irradiation), individually packaged |
| Needle material | Stainless steel coated with silicone |
| Safety mechanism | Irreversible automatic retraction; prevents reuse |
| Activation | By pressure/contact, without prior cocking |
| Use | Single-use, disposable |
| Puncture site | Heel |
Safety lancet family “Safety”
| Reference | Gauge | Depth | Colour | Indication |
|---|---|---|---|---|
| 1110115 | 26G | 1.8 mm | Yellow | Blood glucose test |
| 1110116 | 21G | 1.8 mm | Orange | Thin skin |
| 1110117 | 21G | 2.4 mm | Pink | Normal skin |
| 1110118 | 18G | 1.8 mm | Green | Paediatric heel (this reference) |
Equivalences and cross-references
The following references have been cross-checked against each manufacturer’s public documentation (official catalogues and the GUDID/FDA regulatory database). None constitutes a validated exact reference equivalence, but rather a verified functional comparison, as they differ in colour, design or presentation:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Sarstedt | Safety-Lancet Extra | 85.1017 | Comparable by category (not interchangeable 1:1) | Needle 18G, 1.8 mm depth; for finger, ear and heel; yellow colour (as opposed to green); 200 uds/box; verified in GUDID (model 85.1017). |
| Owen Mumford | Unistik 3 Neonatal & Laboratory | AT1052 | Comparable by category (not interchangeable 1:1) | Needle 18G, 1.8 mm; indicated for neonatal heel sampling; activation by side button and Comfort Zone technology; presentation of 100 uds/box. |
| MediPurpose | SurgiLance Safety (blade style) | SLB200 | Comparable by category (not interchangeable 1:1) | 18G, 1.8 mm, green colour; high-flow blade-type element (approx. 74-100 µl); for finger and heel; box of 100 uds; the closest in gauge, depth and colour. |
In the reference market, the Solofix Safety series from B. Braun (e.g. ref. 6183000DE, Universal 21G 1.8 mm) offers comparable performance in terms of contact puncture and irreversible needle retraction, but its 21G gauge differs from the 18G of this reference, so it is not included as a direct candidate. There is no manufacturer-validated equivalence table linking reference 1110118 with the above codes; the equivalences shown are verified functional comparisons against public sources. Consult the technical department before use in tenders or replacement of approved material.
Selection tips and variants of interest
Choose the 1110118 (18G, 1.8 mm, green) when the procedure requires sampling from the paediatric heel or neonatal screening with a gauge that ensures adequate flow with a single puncture. For routine blood glucose monitoring in fine adult skin, consider the yellow 26G version (ref. 1110115); for thin skin, the orange 21G (ref. 1110116); and for normal skin with greater depth, the pink 21G 2.4 mm (ref. 1110117). The catalogue also includes the sterile rectangular 18G green lancet for paediatric heel (ref. 1110133) and the professional range of safety lancets in 18G/21G/28G (refs. SLN1818, SLN2118, SLN2816) and with a 1.2 mm paediatric blade (ref. SLBLADE12). Remember that these are single-use devices: dispose of them in a sharps container in accordance with current healthcare waste regulations and always follow the manufacturer’s instructions for use.


Reviews
There are no reviews yet.