Description
1. Product Presentation
The sterile rectangular safety blood lancet 18G (1.8 mm) green is a single-use capillary puncture device developed for obtaining blood micro-samples from paediatric heel and neonatal screening. Its rectangular body provides a wide, stable support base, allowing the professional total control over the angle and pressure during puncture, even on the smallest patients’ feet. The green colour code enables quick identification of the correct size, streamlining material preparation in clinics, neonatology units, hospitals, and laboratories. Ref. 1110133.
2. How it works and why it is safe
Capillary puncture of the heel is the standard method for neonatal screening and low-volume blood tests in babies, as it allows the required drop of blood to be obtained with minimal trauma. This lancet is activated simply by pressing it against the puncture site: remove the sterility cap, place the device on the clean heel, and press. The precision-ground needle penetrates in a controlled manner to 1.8 mm and, after triggering, the integrated safety mechanism irreversibly conceals the cutting element, preventing reuse and drastically reducing the risk of accidental needlestick injuries (sharps accidents) and cross-contamination. Each unit is sterile, supplied in an individual pack, and is single-use.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference | 1110133 |
| Product type | Safety blood lancet, single-use |
| Shape | Rectangular (stable support base) |
| Needle gauge | 18G |
| Puncture depth | 1.8 mm |
| Indication | Paediatric heel and neonatal screening |
| Identification colour | Green |
| Sterility | Yes, sterile in individual packaging |
| Safety system | Automatic retraction of the cutting element; prevents reuse |
| Activation | By pressure/contact, without prior cocking |
| Presentation | Box of 100 units |
| Use | Single-use, disposable |
Family of rectangular safety blood lancets
| Reference | Gauge | Depth | Colour | Indication |
|---|---|---|---|---|
| 1110130 | 26G | 1.8 mm | Yellow | Blood glucose test |
| 1110131 | 21G | 1.8 mm | Orange | Thin skin |
| 1110132 | 21G | 2.4 mm | Pink | Normal skin |
| 1110133 | 18G | 1.8 mm | Green | Paediatric heel (this reference) |
4. Equivalences and Cross-References
The following references have been cross-checked against public documentation from each manufacturer (official manufacturer catalogue and GUDID/FDA regulatory database). None of them constitutes a validated exact reference equivalence, but rather a verified functional comparison: they all match in gauge 18G and puncture depth 1.8 mm, but differ in body design, colour or presentation from ref. 1110133.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Sarstedt | Safety-Lancet Extra 18G | 85.1017 | Comparable by category (not interchangeable 1:1) | Needle 18G, 1.8 mm depth; for finger, ear and heel; yellow (versus green); 200 units/box; verified in GUDID. |
| Owen Mumford | Unistik 3 Neonatal & Laboratory | AT1052 | Comparable by category (not interchangeable 1:1) | Needle 18G, 1.8 mm; intended for neonatal heel sampling; activation by side button and Comfort Zone technology; presentation of 100 units/box. |
| MediPurpose | SurgiLance Safety Lancet (blade style) | SLB200 | Comparable by category (not interchangeable 1:1) | 18G, 1.8 mm, green; blade-type high-flow element (approx. 74-100 µl); for finger and heel; box of 100 units; the closest in gauge, depth and colour; verified in GUDID. |
In the reference market, the Solofix Safety series from B. Braun offers comparable performance in terms of contact puncture and irreversible needle retraction, but its variants with 21G needle (1.8 mm, ref. 6183000) and neonatal blade 0.8 mm (2.0 mm, ref. 6183020) do not match the gauge/depth of the 18G 1.8 mm in this datasheet, so they are not included as direct candidates. There is no manufacturer-validated equivalence table linking reference 1110133 with the above codes; the equivalences shown are verified functional comparisons against public sources. Consult the technical department before use in tenders or replacement of approved material.
5. Selection tips and variants of interest
Choose 1110133 (18G, 1.8 mm, green) when the procedure requires sample collection from paediatric heel or neonatal screening with a gauge that ensures adequate flow with a single puncture. For routine blood glucose monitoring, consider the rectangular 26G yellow version (ref. 1110130); for thin skin, the 21G orange (ref. 1110131); and for normal skin requiring greater depth, the 21G pink 2.4 mm (ref. 1110132). The catalogue also includes the sterile 18G green safety lancet for paediatric heel (ref. 1110118) and the professional SLN safety lancet range (18G/21G/28G, refs. SLN1818, SLN2118 and SLN2816) and with paediatric blade 1.2 mm (ref. SLBLADE12). Remember they are single-use devices: dispose of them in a sharps container in accordance with current healthcare waste regulations and always follow the manufacturer’s instructions for use.