Description
1. Product Presentation
The Ergosafe Clipper close-shave head (Ref. CCSB4) is the original Medline replacement for the Ergosafe surgical clipper, the professional solution for hair removal in preoperative patient preparation. Manufactured in an identifying black colour, this head is designed to provide a fine, precise and uniform shave finish, particularly indicated for facial procedures and areas requiring a close, high-quality shave. As a disposable, single-use, non-sterile accessory, each procedure has a new, ready-to-use blade, which reinforces hygiene and infection control protocols in operating theatres, hospital wards and surgical services.
2. Technical explanation of the equipment and procedure
The Medline Ergosafe Clipper surgical clipper is designed for optimal preoperative hair removal, following international recommendations that advise clipping rather than shaving to reduce the risk of surgical site infection. The CCSB4 head is part of the handle’s interchangeable head system and features a fine blade geometry for close shaving, optimised for a flush, comfortable cut without direct pressure on the tissue.
Its safety mechanism positions the moving blade facing downwards with integrated side guards that separate the blade from the patient’s skin, thereby minimising superficial cuts, irritation, scratches and micro-lesions. The system can be used dry or wet, facilitating cleaning and disinfection of the handle between uses, and is indicated as a Class I medical device for facial and body use. As a non-sterile, single-use head, any sterilisation or sharpening tasks are eliminated and consistent performance is guaranteed for each patient.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference | CCSB4 |
| Manufacturer | Medline |
| Head type | Close shave (fine blade) |
| Identification colour | Black |
| Application area | Facial procedures and close-shave finishes |
| Sterility | Non-sterile |
| Use | Disposable, single-use per patient |
| Water resistance | Yes, usable dry or wet |
| Compatibility | Ergosafe Clipper surgical clipper (handles DYND70800EU / DYND70801EU) |
| Clinical indication | Preoperative hair preparation, facial and body use |
| Medical device class | Class I |
| Presentation | Box of 25 units |
| Alternative catalogue code | 729010 |
The range of interchangeable heads for the Ergosafe Clipper surgical clipper is distinguished by a colour code that facilitates rapid identification in the operating theatre:
| Reference | Printhead | Colour | Packaging |
|---|---|---|---|
| CCSB4 | Close shave | Black | 25 units/box |
| CCB3 | Neuro (thick blade) | Blue | 50 units/box |
| CUB1 | Universal | Grey | 50 units/box |
| CNB2 | Sensitive areas | Red | 50 units/box |
4. Equivalences and Cross-References
The CCSB4 head belongs to the Medline Ergosafe Surgical Clipper system (Ergosafe surgical clipper), also marketed within Medline’s patient care catalogue. All disposable heads in the family share the same handle and are interchangeable with each other: CCB3 (Neuro, blue), CUB1 (universal, grey) and CNB2 (sensitive areas, red).
The system’s cross-references include the handle kit with charger DYND70800EU and its UK plug equivalent DYND70800UK, the handle only DYND70801EU and the chargers DYND70802EU / DYND70802UK. On the international market, the device also accepts the blade accessories UBLADEFL, CBLADEFL, NBLADEFL, CSBLADE, DYND70880, DYND70885 and DYND70890. It is always recommended to verify compatibility with the available Ergosafe handle before placing the order and to manage supply using the manufacturer’s reference.
5. Selection tips and variants of interest
To choose the right head for each procedure, remember that the colour system facilitates selection: use the black head (CCSB4) for close-shave finishes on facial areas and maximum smoothness results; the universal grey (CUB1) for general surgery with standard-thickness hair; the red (CNB2) for sensitive areas and delicate regions; and the blue Neuro (CCB3) for scalp hair and thick hair in neurosurgery and thoracic surgery.
As a single-use, non-sterile replacement, it is recommended to order the box of 25 units for continuous replenishment between patients and to adjust stock to the service’s surgical volume. Always verify that the available handle corresponds to the Ergosafe Clipper series (DYND70800 / DYND70801 / DYND70802) for correct fitting. After each use, remove the head and dispose of it according to the centre’s protocol, avoiding sterilisation processes and ensuring maximum hygiene and safety conditions in preoperative hair preparation.









Reviews
There are no reviews yet.