Description
Lancing device for blood lancets – Ref. 1110110
Introducing the personal-use plastic lancing device (ref. 1110110), the reference lancing device in the Cahnos catalogue for capillary blood collection in home and care settings. It is the device that accompanies the universal 23G plastic blood lancets (cod. 1110104): an ergonomic, lightweight and durable body that turns each sample collection into a safe, repeatable and barely perceptible procedure for the patient.
Thanks to its construction in high-resistance, biocompatible plastic, with simple depth adjustment, this device is especially indicated for supervised home glycaemic self-monitoring, primary care consultations, pharmacies and rapid testing laboratories.
How does it work and why choose this lancing device?
The lancing device (also called lancet device or lancing apparatus) is the instrument that houses the lancet and fires it at the fingertip in a standardised and controlled manner. The blood lancet, with a universal 23G profile (0.65 mm), is inserted into the device head; when the mechanism is activated, the needle performs a capillary micropuncture with minimal discomfort, sufficient to obtain the drop of blood required by most glucose meters and point-of-care testing equipment.
- Simple depth adjustment: allows the needle penetration to be adjusted according to skin thickness (normal adult skin, thin or sensitive skin), minimising pain and excessive bleeding.
- Personal use: designed as an individual-use device; the lancet is disposable and single-use, preventing cross-contamination.
- Universal compatibility: suitable for plastic blood lancets with a standard 23G profile, such as ref. 1110104 (box of 100 units).
Technical specifications
| Product type | Lancing device (lancet holder) for blood lancets |
| Reference | Ref. 1110110 (Code 1110104) |
| Material | High-strength and biocompatible plastic |
| Depth adjustment | Yes. Simple adjustment for various skin penetration depths |
| Compatibility | Suitable for universal plastic blood lancets 23G (ref. 1110104) |
| Presentation | Box of 50 units |
| Intended use | Capillary puncture for glycaemic self-monitoring and blood sampling; personal use |
| Sterility | Non-sterile device (personal-use device; the compatible lancets are disposable and single-use) |
Equivalences and cross-references
At category level, ref. 1110110 corresponds to the GMDN family of reusable manual blood lancing devices (manual blood lancing device, reusable). The following homologous devices from other manufacturers have been cross-checked against the GUDID/FDA regulatory database. None of the rows constitutes a validated exact reference equivalence: these are verified functional comparisons, since the lancet coupling and the firing system are specific to each brand.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Owen Mumford | Autolet (lancing device) | AT 0271 | Comparable by category (not interchangeable 1:1) | Reusable manual lancing device registered in GUDID (UDI 00384700271015); adjustable depth; compatible with Unilet family lancets; geometry and firing mechanism specific to Owen Mumford, not interchangeable 1:1 with ref. 1110110. |
| Owen Mumford | Autolet (lancing device) | AT 0270 | Comparable by category (not interchangeable 1:1) | Reusable manual lancing device registered in GUDID (UDI 00384700270018); same functional profile as the AT 0271; requires Owen Mumford system lancets, does not directly accept the geometry of ref. 1110110. |
There is no official equivalence table validated by the manufacturer relating ref. 1110110 to codes from other brands; the above codes are verified functional comparisons against public regulatory sources (GUDID/FDA). Diagnostic lancing devices from other clinical supplies brands also operate in this segment (e.g. lancing devices associated with Vitrex lancets and similar), whose official code could not be verified in primary sources; consult the technical department before using them in tenders or as replacements for approved material.
Selection tips and variants of interest
If you work with universal 23G plastic blood lancets, ref. 1110110 is the recommended lancing device to complete your capillary lancing system: the recommended consumable is the universal 23G plastic lancet, ref. 1110104 (SKU 0658015-1, box of 100 units). For specific needs, the Cahnos catalogue offers other lancing solutions: safety blood lancets from the Safety range (refs. 1110115, 1110116 and 1110117) with retraction mechanism for needlestick prevention; sterile rectangular lancets for thin skin and paediatric heel (refs. 1110131, 1110132 and 1110133); and next-generation lancets with 1.6 mm puncture, colour-coded (23G red ref. 1110126, 26G grey ref. 1110127, 28G yellow ref. 1110128 and 30G green ref. 1110129).
Remember to adjust the device depth according to skin type, alternate the puncture site between fingers and dispose of each used lancet in a sharps container in accordance with current healthcare waste regulations.


Reviews