Description
1. Introduction
The silicone ring pessary with support (ref. 30042, Ø 57 mm, white) is a conservative, non-surgical solution for the management of first and second degree uterine prolapse when accompanied by mild cystocele. Its ring-with-support design restores the anatomical position of the pelvic organs comfortably, safely and effectively, providing immediate relief from the descent and associated symptoms, as an alternative to surgical intervention.
Manufactured entirely from medical-grade silicone and 100% latex-free, it is especially suitable for patients with sensitivity or allergy to latex and metal. It is supplied individually, in an individual cardboard package, ready for clinical use in gynaecology, urogynaecology and pelvic floor clinics. The box and instructions are multilingual (including Spanish), which facilitates dispensing, traceability and use.
2. Technical explanation of the device
The ring pessary acts as an intravaginal mechanical support element: it surrounds the cervix and keeps the uterus and vaginal walls elevated, reducing the symptoms of grade I-II prolapse. The support variant adds a bearing surface that better distributes pressure over the anterior vaginal wall, specifically relieving mild cystocele, and provides suburethral support that helps control stress urinary incontinence. It also provides support in cases of rectocele.
It is an invasive device inserted vaginally through a natural orifice, without the need for connection to any active medical equipment. Its elastic ring design allows it to be folded to facilitate insertion and removal, then recovering its original shape. It is intended for single-patient use (monopatient) and provides immediate relief, allowing the patient to immediately resume her daily activities. Placement, dwell time and follow-up must always be indicated and supervised by a gynaecologist or qualified specialist, who must prescribe and position the device.
3. Technical Specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II A |
| CND | U089005 |
| EAN | 6972994800130 |
Technical features
| Designation | Silicone ring pessary with support – white |
|---|---|
| Manufacturer reference | 30042 (SKU Cahnos: GM30042) |
| Diameter | Ø 57 mm |
| Colour | White |
| Material | Medical-grade silicone, latex-free |
| Indications | First and second degree uterine prolapse complicated by mild cystocele; support for cystocele, rectocele and stress urinary incontinence |
| Use | Single patient |
| Presentation | Individual packaging in cardboard box; box and instructions multilingual: GB, FR, IT, ES, PT, DE, NL, SE, LV, PL, HU, SI, HR, RO, BG, GR and Arabic |
Medical-grade silicone ensures softness and flexibility, and its latex-free composition makes it suitable for patients with sensitivity or allergy to latex.
Available references (support series)
| Reference | Description | Diameter |
|---|---|---|
| 30040 | Silicone ring pessary with support | Ø 45 mm |
| 30041 | Silicone ring pessary with support | Ø 51 mm |
| 30042 | Silicone ring pessary with support | Ø 57 mm (product analysed) |
| 30043 | Silicone ring pessary with support | Ø 64 mm |
4. Equivalences and Cross-References
No equivalence table validated by the manufacturer is available for this reference. Silicone ring pessaries with support constitute a category present in other manufacturers in the sector, such as Dr. Arabin (ring pessary), Corysan, Fleming Comercial or CooperSurgical Milex (ring/folding pessary), but in no case are they declared interchangeable 1:1 with reference 30042. Before any substitution, the material, diameter, presence of support or internal reinforcement, sterility and usage protocol in each manufacturer’s technical data sheet must always be compared. It is recommended to consult the technical department before use in tendering.
Within the catalogue itself and in Cahnos there are other complementary families of silicone pessaries: latex-free silicone ring pessaries in sizes from 50 to 90 mm (refs. 0126018 to 0126021) for grade I-II prolapses, Gellhorn-type mushroom pessaries (refs. Ref. 30055 to 30057 / GM30055 to GM30057) for higher-grade prolapses, and silicone cube pessaries with drainage (refs. Ref. 30071 to 30075). In all cases, compare the technical data sheet of each reference beforehand.
5. Selection tips and variants of interest
The choice of pessary and its size must be made by the specialist after pelvic examination: the smallest size that eliminates the symptoms of the prolapse should be used, checking that there is a space of approximately one finger (10–15 mm) between the pessary edge and the vaginal wall to avoid excessive pressure or pressure necrosis. For insertion, fold the ring, pass the introitus and release the device so that it recovers its shape; a silicone-compatible vaginal lubricant may be used.
The ring pessary with support is recommended for grade I-II prolapses complicated by mild cystocele, where the additional anterior support improves correction of the vaginal wall descent; if this complication is not present, the silicone ring pessary series without support in the same range may be considered. As it is a 100% silicone piece without a metal core, it is especially indicated in patients with allergy or sensitivity to latex and metal. All products in this range must be prescribed and placed by a specialised healthcare professional.