Rapid Test for Fetal Membrane Rupture (RMF) iGFBP-1 Cassette | Professional Use Amniotic Sac Rupture Test | Ref. FIG-502

Price on request

Rapid test for fetal membrane rupture (RMF) by qualitative immunochromatographic detection of the protein iGFBP-1 in vaginal secretions during pregnancy, the reference marker for amniotic fluid. Visual reading within minutes, without the need for additional equipment, with a relative sensitivity of 98.10% and specificity of 98.00%. Each kit includes a test cassette, sampling tube with extraction buffer and sterile swab. Indicated for obstetrics departments, hospital emergency units and gynaecology clinics for the early diagnosis of premature rupture of membranes. Reference FIG-502.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIG-502

Description

1. Introduction

The rapid test for fetal membrane rupture is the reference diagnostic solution for early and reliable confirmation of rupture of the amniotic sac in pregnant women. By qualitative detection of the protein iGFBP-1 (insulin-like growth factor-binding protein type 1) in vaginal secretions, this test allows the presence of amniotic fluid to be distinguished with high accuracy from other physiological secretions, facilitating clinical decision-making in obstetrics departments, hospital emergency units, delivery rooms and gynaecology clinics. It is a professional-use device, simple to handle and with immediate visual reading, requiring no specialised equipment. Reference FIG-502.

2. Principle of the test and procedure

The test is based on a chromatographic lateral flow immunoassay. Specific antibodies against iGFBP-1, a biomarker present in high concentration in amniotic fluid and practically absent in normal vaginal secretions, are immobilised on the reactive membrane of the cassette. The sample is obtained using the included sterile swab, introduced into the sampling tube with extraction buffer, and a few drops of the extracted sample are placed in the well (S) of the cassette. If the sample contains iGFBP-1, a coloured line appears in the test region (T); the control line (C) validates the correct development of the assay. The reading is qualitative and visual within a few minutes, which speeds up confirmation of membrane rupture at the point of patient care, even outside laboratory hours.

3. Technical Specifications

The general characteristics, kit contents, packaging and clinical data of the product are detailed below.

General characteristics
Reference FIG-502
Marker detected iGFBP-1 (insulin-like growth factor-binding protein 1)
Sample type Vaginal secretions via swab
Method Lateral flow immunochromatography, qualitative and visual reading
Use Professional, diagnosis of fetal membrane rupture (RMF)
CE declaration of conformity
Available on request
Packaging
Units 1 test/kit
Box 25 tests/box
Cardboard 25 boxes/carton
Dimensions 63 × 37 × 30 cm
Box contents
  • 1 × Test cassette
  • 1 × Sampling tube with extraction buffer
  • 1 × Sterile swab
  • 1 × Instruction manual
Clinical data
(Available on request)
Relative sensitivity 98.10 %
Relative specificity 98.00 %
Accuracy 98.00 %

4. Equivalences and Cross-References

Reference FIG-502 belongs to the family of rapid immunochromatographic cassette tests with swab used by the original manufacturer (AllTest/Metzecare range) and is complemented in the Cahnos catalogue with other clinical tests from the same line: IMP-502 (rapid antigen test for Mycoplasma pneumoniae) and IBP-502 (rapid test for Bordetella pertussis), which share format, methodology and presentation. From a functional point of view, this iGFBP-1 test is the professional standard compared with orientation test strips such as Amnioquick (reference 431006N-20, also available from Cahnos), offering a specific marker for amniotic fluid with a lower risk of false positives due to vaginal contamination. Furthermore, iGFBP-1 determination is the technology used by manufacturers such as Certum (PROM line) and Healgen, which facilitates supply homologation and comparison of clinical data in purchasing centres and materials committees.

5. Selection tips and variants of interest

For obstetrics and emergency departments with a high patient volume, the 25-test-per-box presentation is the most practical option, and the carton format (25 boxes, 625 determinations) optimises the cost per test and the centre’s logistical supply. If your centre routinely uses rapid orientation test strips, you can maintain a mixed stock with the Amnioquick test (431006N-20); for diagnostic confirmation and follow-up of patients at risk of preterm labour, the iGFBP-1 FIG-502 test is the recommended alternative due to its specific marker and high accuracy. Always follow the instruction manual, respect the indicated reading time and store the kit in a cool, dry place until use. For volume quotations, technical documentation, declarations of conformity or custom presentation variants, please contact our sales department.

Additional information

Reference

FIG-502

Marker detected

iGFBP-1 (insulin-like growth factor-binding protein 1)

Method

Qualitative lateral flow immunochromatography with visual reading

Sample type

Vaginal secretions (swab)

Use

Professional, diagnosis of fetal membrane rupture (RMF)

Relative sensitivity

98.10 %

Relative specificity

98.00 %

Precision

98.00 %

Presentation

1 test/kit · 25 tests/box · 25 boxes/carton

Contents

Test cassette, sampling tube with extraction buffer, sterile swab and instruction manual

Carton dimensions

63 × 37 × 30 cm