Description
1. Introduction
The rapid test for fetal membrane rupture is the reference diagnostic solution for early and reliable confirmation of rupture of the amniotic sac in pregnant women. By qualitative detection of the protein iGFBP-1 (insulin-like growth factor-binding protein type 1) in vaginal secretions, this test allows the presence of amniotic fluid to be distinguished with high accuracy from other physiological secretions, facilitating clinical decision-making in obstetrics departments, hospital emergency units, delivery rooms and gynaecology clinics. It is a professional-use device, simple to handle and with immediate visual reading, requiring no specialised equipment. Reference FIG-502.
2. Principle of the test and procedure
The test is based on a chromatographic lateral flow immunoassay. Specific antibodies against iGFBP-1, a biomarker present in high concentration in amniotic fluid and practically absent in normal vaginal secretions, are immobilised on the reactive membrane of the cassette. The sample is obtained using the included sterile swab, introduced into the sampling tube with extraction buffer, and a few drops of the extracted sample are placed in the well (S) of the cassette. If the sample contains iGFBP-1, a coloured line appears in the test region (T); the control line (C) validates the correct development of the assay. The reading is qualitative and visual within a few minutes, which speeds up confirmation of membrane rupture at the point of patient care, even outside laboratory hours.
3. Technical Specifications
The general characteristics, kit contents, packaging and clinical data of the product are detailed below.
| General characteristics | |
|---|---|
| Reference | FIG-502 |
| Marker detected | iGFBP-1 (insulin-like growth factor-binding protein 1) |
| Sample type | Vaginal secretions via swab |
| Method | Lateral flow immunochromatography, qualitative and visual reading |
| Use | Professional, diagnosis of fetal membrane rupture (RMF) |
| CE declaration of conformity | |
|---|---|
| Available on request |
| Packaging | |
|---|---|
| Units | 1 test/kit |
| Box | 25 tests/box |
| Cardboard | 25 boxes/carton |
| Dimensions | 63 × 37 × 30 cm |
| Box contents | |
|---|---|
|
| Clinical data | |
|---|---|
| (Available on request) | |
| Relative sensitivity | 98.10 % |
| Relative specificity | 98.00 % |
| Accuracy | 98.00 % |
4. Equivalences and Cross-References
Reference FIG-502 belongs to the family of rapid immunochromatographic cassette tests with swab used by the original manufacturer (AllTest/Metzecare range) and is complemented in the Cahnos catalogue with other clinical tests from the same line: IMP-502 (rapid antigen test for Mycoplasma pneumoniae) and IBP-502 (rapid test for Bordetella pertussis), which share format, methodology and presentation. From a functional point of view, this iGFBP-1 test is the professional standard compared with orientation test strips such as Amnioquick (reference 431006N-20, also available from Cahnos), offering a specific marker for amniotic fluid with a lower risk of false positives due to vaginal contamination. Furthermore, iGFBP-1 determination is the technology used by manufacturers such as Certum (PROM line) and Healgen, which facilitates supply homologation and comparison of clinical data in purchasing centres and materials committees.
5. Selection tips and variants of interest
For obstetrics and emergency departments with a high patient volume, the 25-test-per-box presentation is the most practical option, and the carton format (25 boxes, 625 determinations) optimises the cost per test and the centre’s logistical supply. If your centre routinely uses rapid orientation test strips, you can maintain a mixed stock with the Amnioquick test (431006N-20); for diagnostic confirmation and follow-up of patients at risk of preterm labour, the iGFBP-1 FIG-502 test is the recommended alternative due to its specific marker and high accuracy. Always follow the instruction manual, respect the indicated reading time and store the kit in a cool, dry place until use. For volume quotations, technical documentation, declarations of conformity or custom presentation variants, please contact our sales department.





Reviews