We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Professional Pregnancy Test – hCG Detection in Urine 20 mUI/ml | Midstream, Strip and Cassette Formats | Ref. GM29090 / GM29091 / GM29092

Price range: 7,60 € through 19,95 €

The Professional Use Pregnancy Test (IVD) qualitatively detects the hCG hormone in urine with a sensitivity of 20 mUI/ml and 99.9% reliability. Result in just 3 minutes, with early detection from the first day of a missed period. It is available in three formats: midstream (box of 25 units), 4 mm strip (box of 50 units) and cassette (box of 40 units), each individually packed in a sealed aluminium sachet. Includes multilingual manual and 36-month shelf life. For large orders you can request a quote: contact our commercial team.

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM29090-F

Description

1. Introduction

The Professional Use Pregnancy Test is the in vitro diagnostic (IVD) solution designed for gynaecology practices, health centres, laboratories and hospital services that need to confirm pregnancy quickly, reliably and with volume control. The professional range offers three test formats —midstream, 4 mm strip and cassette— with the same sensitivity of 20 mUI/ml, so the centre can choose the system that best suits its workflow. Each test is individually packed in a sealed aluminium sachet and supplied in a cardboard box with a multilingual instruction manual (GB, IT, ES, FR, GR, PT).

2. Technical explanation of the procedure

The test is based on a lateral flow chromatographic immunoassay that qualitatively detects human chorionic gonadotropin (hCG), a hormone released after embryo implantation whose concentration increases rapidly during the first weeks of gestation. With a detection threshold of 20 mUI/ml, the test can be used from the first day of a missed menstrual period. The reading is visual and is obtained in approximately 3 minutes: the control line confirms the validity of the test and the test line indicates a positive result. The midstream format is applied directly to the urine stream; the strip is immersed in the sample, and the cassette receives a few drops in its well.

3. Technical Specifications

Range for professional use (Professional Test) for the detection of hCG in urine, with 99.9% reliability, clinically tested and a shelf life of 36 months from the date of manufacture.

Reference Model Sales unit Details
GM29090 midstream box of 25 units PROFESSIONAL TEST · Type: midstream
GM29091 4 mm strip box of 50 units PROFESSIONAL TEST · Type: 4 mm strip
GM29092 cassette box of 40 units PROFESSIONAL TEST · Type: cassette
Manufacturer GIMA
Device type IVD – Professional Use
CND W0102160302
Parameter Specification
Analyte detected Human chorionic gonadotropin (hCG) – qualitative detection
Sample type Urine
Sensitivity 20 mUI/ml
Reliability 99.9 %
Time to result 3 minutes
Early detection From the first day of a missed period
Individual packaging Aluminium sealed sachet
Instruction manual Multilingual (GB, IT, ES, FR, GR, PT)
Clinical validation Clinically tested
Expiry 36 months from date of manufacture

4. Equivalences and Cross-References

Within the pregnancy test family, the three professional references share the same immunochromatographic technology, the same marker (hCG in urine) and the same sensitivity of 20 mUI/ml, so they are interchangeable for analytical criteria purposes and differ only in the application format:

  • Professional range (professional use): GM29090 (midstream, box of 25 units), GM29091 (4 mm strip, box of 50 units) and GM29092 (cassette, box of 40 units). Official catalogue references.
  • Self-test range (self test): GM29097 / GM29098 (midstream, 20 mUI/ml) and GM29103 (wide strip midstream, 10 mUI/ml), for the retail sales channel.
  • Digital range: DISTINCT® Digital Pregnancy Test, refs. GM29085 / GM29086, with a sensitivity of 10 mUI/ml and digital reading.

There is no 1:1 equivalence table validated by the manufacturer with other brands. Before replacing any reference in tendering or prescribing processes, check in each technical data sheet the detected marker (hCG), the sensitivity (mUI/ml), the sample type (urine), the device format (midstream, strip or cassette), the reading time and the intended use (self-test versus professional use).

5. Selection tips and variants of interest

  • Midstream format (GM29090): direct application to the urine stream, without containers or pipettes; recommended for practices with a medium volume of tests.
  • 4 mm strip format (GM29091): maximum economy per test and 50 units per box; ideal for services with high consumption.
  • Cassette format (GM29092): sample deposited with a pipette or dropper onto the well; good reading stability, suitable for laboratory or workbench.
  • Timing: preferably with the first morning urine, due to its higher hCG concentration. A negative result obtained very early may be due to an insufficient concentration: if in doubt, repeat after 2-3 days.
  • Storage: keep each test in its original sealed sachet, in a cool, dry place, protected from moisture and direct sunlight; respect the expiry date and do not reuse the test.
  • For volume orders, special conditions or additional technical documentation, contact our commercial department at Cahnos.

Additional information

Modelo

midstream, strip 4 mm, cassette

CND code

W0102160302

References

GM29090 (midstream, box of 25 units) · GM29091 (4 mm strip, box of 50 units) · GM29092 (cassette, box of 40 units)

Method

Lateral flow chromatographic immunoassay (qualitative)

Analyte detected

Human chorionic gonadotropin (hCG)

Sample type

Urine

Sensitivity

20 mUI/ml

Reliability

99.9 %

Time to result

Approximately 3 minutes

Early detection

From the first day of a missed period

Format

Midstream · 4 mm strip · cassette

Individual packaging

Aluminium sealed sachet

Instruction manual

Multilingual (GB, IT, ES, FR, GR, PT)

Clinical validation

Clinically tested

Shelf life

36 months from date of manufacture

Use

Professional, single-use

Tipo dispositivo

In vitro diagnostics

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF · Label Prodotto PDF
📜 Declaration of conformityEnglish PDF · English PDF · English PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Professional Pregnancy Test – hCG Detection in Urine 20 mUI/ml | Midstream, Strip and Cassette Formats | Ref. GM29090 / GM29091 / GM29092”

Your email address will not be published. Required fields are marked *