Description
1. Introduction
The Professional Use Pregnancy Test is the in vitro diagnostic (IVD) solution designed for gynaecology practices, health centres, laboratories and hospital services that need to confirm pregnancy quickly, reliably and with volume control. The professional range offers three test formats —midstream, 4 mm strip and cassette— with the same sensitivity of 20 mUI/ml, so the centre can choose the system that best suits its workflow. Each test is individually packed in a sealed aluminium sachet and supplied in a cardboard box with a multilingual instruction manual (GB, IT, ES, FR, GR, PT).
2. Technical explanation of the procedure
The test is based on a lateral flow chromatographic immunoassay that qualitatively detects human chorionic gonadotropin (hCG), a hormone released after embryo implantation whose concentration increases rapidly during the first weeks of gestation. With a detection threshold of 20 mUI/ml, the test can be used from the first day of a missed menstrual period. The reading is visual and is obtained in approximately 3 minutes: the control line confirms the validity of the test and the test line indicates a positive result. The midstream format is applied directly to the urine stream; the strip is immersed in the sample, and the cassette receives a few drops in its well.
3. Technical Specifications
Range for professional use (Professional Test) for the detection of hCG in urine, with 99.9% reliability, clinically tested and a shelf life of 36 months from the date of manufacture.
| Reference | Model | Sales unit | Details |
|---|---|---|---|
| GM29090 | midstream | box of 25 units | PROFESSIONAL TEST · Type: midstream |
| GM29091 | 4 mm strip | box of 50 units | PROFESSIONAL TEST · Type: 4 mm strip |
| GM29092 | cassette | box of 40 units | PROFESSIONAL TEST · Type: cassette |
| Manufacturer | GIMA |
|---|---|
| Device type | IVD – Professional Use |
| CND | W0102160302 |
| Parameter | Specification |
|---|---|
| Analyte detected | Human chorionic gonadotropin (hCG) – qualitative detection |
| Sample type | Urine |
| Sensitivity | 20 mUI/ml |
| Reliability | 99.9 % |
| Time to result | 3 minutes |
| Early detection | From the first day of a missed period |
| Individual packaging | Aluminium sealed sachet |
| Instruction manual | Multilingual (GB, IT, ES, FR, GR, PT) |
| Clinical validation | Clinically tested |
| Expiry | 36 months from date of manufacture |
4. Equivalences and Cross-References
Within the pregnancy test family, the three professional references share the same immunochromatographic technology, the same marker (hCG in urine) and the same sensitivity of 20 mUI/ml, so they are interchangeable for analytical criteria purposes and differ only in the application format:
- Professional range (professional use): GM29090 (midstream, box of 25 units), GM29091 (4 mm strip, box of 50 units) and GM29092 (cassette, box of 40 units). Official catalogue references.
- Self-test range (self test): GM29097 / GM29098 (midstream, 20 mUI/ml) and GM29103 (wide strip midstream, 10 mUI/ml), for the retail sales channel.
- Digital range: DISTINCT® Digital Pregnancy Test, refs. GM29085 / GM29086, with a sensitivity of 10 mUI/ml and digital reading.
There is no 1:1 equivalence table validated by the manufacturer with other brands. Before replacing any reference in tendering or prescribing processes, check in each technical data sheet the detected marker (hCG), the sensitivity (mUI/ml), the sample type (urine), the device format (midstream, strip or cassette), the reading time and the intended use (self-test versus professional use).
5. Selection tips and variants of interest
- Midstream format (GM29090): direct application to the urine stream, without containers or pipettes; recommended for practices with a medium volume of tests.
- 4 mm strip format (GM29091): maximum economy per test and 50 units per box; ideal for services with high consumption.
- Cassette format (GM29092): sample deposited with a pipette or dropper onto the well; good reading stability, suitable for laboratory or workbench.
- Timing: preferably with the first morning urine, due to its higher hCG concentration. A negative result obtained very early may be due to an insufficient concentration: if in doubt, repeat after 2-3 days.
- Storage: keep each test in its original sealed sachet, in a cool, dry place, protected from moisture and direct sunlight; respect the expiry date and do not reuse the test.
- For volume orders, special conditions or additional technical documentation, contact our commercial department at Cahnos.