Description
1. Introduction
The rigid straight Intracurette intrauterine suction cannula is the reference consumable for controlled intrauterine suction in gynaecology and obstetrics. Its rigid, straight body faithfully transmits the specialist’s movements, providing direct access to the cervical canal without losing control of the procedure. It is supplied sterile, in individual packaging and in a box of 50 units, ready for use in the consulting room, women’s health unit or operating theatre. A disposable solution that eliminates the risks associated with re-sterilisation and ensures traceability and safety in every procedure.
2. Technical explanation of the equipment and procedure
Intrauterine suction is a minimally invasive technique that involves evacuating the contents of the uterine cavity using controlled vacuum. The rigid straight cannula connects directly to the suction tube of the vacuum system (pump or surgical suction unit) and is introduced through the cervical canal into the uterine cavity. The frosted insertion band on the shaft allows the depth of insertion to be visualised during the procedure, while the tip with smoothed edges reduces the risk of tissue injury and uterine perforation. By performing controlled rotational movements, the negative pressure effectively detaches and aspirates the endometrial tissue. It is a technique widely used in voluntary termination of pregnancy, in evacuation after spontaneous abortion and in suction curettage, as well as in endometrial sampling for histological study.
3. Technical Specifications
| Model | Intracurette, rigid straight series (RR) |
| Type | Rigid straight cannula |
| Length | 18 cm (18.5 cm according to the manufacturer’s technical data sheet) |
| Diameters | Ø 7, 8, 9, 10, 11 and 12 mm |
| Tip | Smoothed edges, with suction orifice |
| Depth marks | Frosted band to visualise insertion |
| Connection | Direct to the suction tube (universal connector) |
| Sterilisation | Ethylene oxide (EtO) |
| Use | Single-use (disposable), not re-sterilisable |
| Presentation | Box of 50 units, individual packaging |
| Marking | CE 0051 · Medical device according to Regulation (EU) 2017/745 |
This article is marketed as global reference CARRIC and corresponds to the following official factory codes, according to the manufacturer’s technical data sheet:
| Diameter | Factory reference |
| Ø 7 mm | 720164 |
| Ø 8 mm | 720121 |
| Ø 9 mm | 720122 |
| Ø 10 mm | 720123 |
| Ø 11 mm | 720124 |
| Ø 12 mm | 720125 |
4. Equivalences and Cross-References
There is no cross-reference equivalence table validated by the manufacturer for this reference; the alternatives listed below correspond to the same product category (rigid straight intrauterine suction cannula, sterile and single-use, Ø 7–12 mm) and may be used as support in homologation processes, subject to prior technical verification of each data sheet.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| MedGyn | Disposable Vacuum Curette – Rigid Straight | 022207–022212 (Ø 7–12 mm) | Comparable by category (not interchangeable 1:1) | Same diameters Ø 7–12 mm, sterile and single-use, presentation in box of 50 units; length not published in the manufacturer’s official data sheet. Verified on the official MedGyn website and authorised distributors. |
| Medline | Straight uterine suction curette (open tips) | UCS07 – UCS12 (Ø 7–12 mm) | Comparable by category (not interchangeable 1:1) | Transparent rigid resin with moulded identification and orientation marks, sterile and disposable; presentation in box of 20 units. Verified in the official Medline catalogue. |
| Kaltek | Berkeley rigid straight cannula | 3779 (Ø 7) · 3733–3737 (Ø 8–12 mm) | Comparable by category (not interchangeable 1:1) | Flute-tip, ABS Terlux 2802 TR material, length 185 mm, latex-free and phthalate-free, sterilised by EtO; presentation in box of 100 units. Verified in the manufacturer’s official catalogue. |
| Purple Surgical | Rigid Straight Curettes | PS6007 – PS6012 (Ø 7–12 mm) | Comparable by category (not interchangeable 1:1) | Same clinical indication (vacuum uterine suction), internal Ø 7–12 mm, length 190 mm, atraumatic tip and depth marks; presentation in box of 10 units. Verified on the manufacturer’s official website. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The cited references have been verified in public sources (official manufacturer websites and technical catalogues). Factory codes 720164 and 720121–720125 correspond to the Intracurette rigid straight series, according to the official technical data sheet for the line; as they cannot be verified in public databases (GUDID/EUDAMED), it is recommended to confirm them with the manufacturer before use in tenders.
5. Selection tips and variants of interest
Select the diameter according to the cervical canal and the type of procedure: 7–9 mm calibres are the most common for endometrial sampling and early-stage evacuations, while 10–12 mm calibres are reserved for higher-flow evacuations. The rigid straight version offers direct, controlled access; if you prefer to adapt to the natural angulation of the cervical canal, consider the rigid curved version (Ref. CARCIC) or the flexible Karman type (Ref. CATKIC), both from the same Intracurette model and in boxes of 50 units. To complete the suction system, combine this cannula with the gynaecological suction tubes TUB106/TUB1010, the ROVAC 720133 set or with the straight (UCS06–UCS16) and curved (UCC06–UCC16) uterine suction curettes. Request a quote for volume needs in hospital purchases and tender processes.





Reviews
There are no reviews yet.