Description
1. Introduction
The Cornier-type endometrial suction cannula (Rampipella) with two openings is the reference device in gynaecological consultations for endometrial sampling with maximum patient comfort. Presented in a box of 25 units, this sterile single-use cannula combines an atraumatic design with a manual vacuum system that requires no pump or auxiliary syringe, ensuring precision, speed and safety in every procedure. Designed by gynaecologists for daily practice, it offers a simple technique, excellent patient acceptance and documented clinical performance, with representative tissue collection in each sampling.
2. Technical explanation of the procedure
Endometrial suction is a minimally invasive diagnostic technique that involves obtaining a sample of the uterine mucosa for cytological and histological analysis. The Cornier cannula is inserted through the cervical canal into the uterine cavity without the need for prior dilation; once inside, manual retraction of the internal mandrel (plunger) generates negative pressure that adheres the tissue to the cannula wall. The variant with two openings distributes suction better, which is especially useful when a larger sample is required or when a greater surface area of the endometrial wall needs to be covered. By performing a rotating movement between the fingers while gently moving between the uterine fundus and the internal cervical os, optimal contact with the endometrial wall is achieved and a representative sample is obtained in about 30 seconds.
- Atraumatic rounded tip: facilitates insertion and minimises discomfort.
- Centimetre scale from 1 to 7 cm: allows insertion depth to be controlled during the manoeuvre.
- Manual vacuum with internal plunger: total autonomy, without pump or syringes.
- No dilation or cervical traction: maximum patient acceptance and lower risk of discomfort.
3. Technical Specifications
Summary technical data sheet for reference 0438107:
| Reference | 0438107 |
| Product type | Cornier-type endometrial suction cannula (Rampipella) |
| Tip configuration | Two suction openings (Rampipella) |
| Material | Medical-grade polypropylene (PP) |
| Length | 24.5 cm |
| Outer diameter | 3.1 mm (nominal Ø 3 mm) |
| Centimetre scale | 1 to 7 cm (resolution of 1 cm) |
| Suction system | Plunger or internal manual vacuum mandrel |
| Sterility | Sterile, sterilised by ethylene oxide (EO) |
| Use | Single-use (disposable), not re-sterilisable |
| Validity | 5 years |
| Intended use | Endometrial sampling by suction (cytology) and postcoital tests |
| Classification | Medical device with CE marking, Regulation (EU) 2017/745 |
| Presentation | Box of 25 units |
Family range
This reference belongs to the family of Rampipella-type endometrial suction cannulas in the Cahnos catalogue, available in two configurations:
| Reference | Configuration | Length | Outer Ø | Presentation |
| 720196 | One opening (Rampipella) | 24.5 cm | 3.1 mm | Box of 25 units |
| 0438107 | Two openings (Rampipella) | 24.5 cm | 3.1 mm | Box of 25 units |
4. Equivalences and Cross-References
There is no cross-reference equivalence table validated by the manufacturer for this reference. The alternatives from other manufacturers listed below correspond to the same product category —sterile single-use endometrial suction cannula with manual vacuum and 3.1 mm diameter— and may be used as a reference in purchasing and approval processes, subject to technical verification.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| CooperSurgical | Pipelle – endometrial suction curette (Ø 3.1 mm) | 8200 | Comparable by category (not interchangeable 1:1) | Sterile, single-use and box of 25 units; verified on the manufacturer’s official website and in GUDID (DI 00888937003475). Same calibre (3.1 mm): differs in one lateral opening (as opposed to two), approximate length of 23.5 cm and semi-rigid plastic resin material not confirmed as PP. |
| MedGyn | Pipette – endometrial suction cannula 3.1 mm | 022721 | Comparable by category (not interchangeable 1:1) | Verified on the manufacturer’s official website (box of 25 units, Ø 3.1 mm). Semi-rigid conical cannula of 23.5 cm with one opening, as opposed to the two openings of 24.5 cm of this reference. |
| MedGyn | Pipette IV – multi-opening cannula 3.1 mm | 022730 | Comparable by category (not interchangeable 1:1) | Verified on the manufacturer’s official website (box of 25 units, Ø 3.1 mm). Four-opening design and length of 23.5 cm; same clinical indication, different tip configuration. |
| GIMA | Sterile Pipella with one opening | 29826 | Comparable by category (not interchangeable 1:1) | Outer Ø 3.1 mm, cannula of 23.5 cm and one opening; usual presentation of 100 units (boxes of 25 on request). Verified in catalogues of authorised distributors; confirm with the manufacturer before use. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The references cited have been verified in public sources (official manufacturer websites and GUDID/FDA database) or, as support, in catalogues of authorised distributors. Reference 1103000 from Laboratoires CCD, cited in some secondary sources, could not be verified in official sources and is pending confirmation with the manufacturer. Always verify length, diameter, number of openings, material and presentation in the official technical data sheet of each manufacturer.
5. Selection tips and variants of interest
1 orifice versus 2 orifices: the single-orifice version (ref. 720196) offers focal suction, particularly suitable for cytological samples and in-clinic screening; the two-orifice version (ref. 0438107), the subject of this datasheet, distributes suction better when a wider sample is required.
Depth control: it is recommended to check the uterine depth beforehand with a hysterometer and to respect the centimetre scale from 1 to 7 cm during insertion to avoid passing beyond the uterine fundus.
Sample handling: after collection, cut the tip and push the plunger to deposit the sample into the container with histological fixative; dispose of the device after use.
Kit compatibility: at Cahnos the complete suction collection solution is available, such as the Citovac 4 kit (ref. 0438023, includes cannula, syringe, tube and label), and intrauterine suction cannulas (ref. CARRIC) for procedures with a suction unit.
Storage: keep the packaging intact in a cool, dry place; use before the indicated expiry date and only if the packaging is undamaged.
Hospital purchasing: for volume requirements and tender processes, contact our sales team for special quantity conditions.





Reviews
There are no reviews yet.