Description
Cornier endometrial suction cannula (Rampipella) — box of 25 units
The Cornier endometrial suction cannula (Rampipella) is the reference device in gynaecological consultations for taking endometrial cytological samples with maximum patient comfort. Supplied in a box of 25 units, this sterile single-use cannula combines an atraumatic design with a manual vacuum system that requires no pump or auxiliary syringe, ensuring precision, speed and safety in every procedure.
Designed by gynaecologists for daily practice, it offers a simple technique, excellent patient acceptance and documented clinical performance, with representative tissue collection in each sample. Its configuration of one lateral opening provides focal suction, particularly indicated for cytological samples and endometrial screening in the consultation.
Technical explanation: how endometrial suction is performed
Endometrial suction is a minimally invasive diagnostic technique that involves obtaining a sample of the uterine mucosa for cytological and histological analysis. The Cornier cannula is introduced through the cervical canal into the uterine cavity without prior dilation; once inside, manual retraction of the internal mandrel (piston) generates negative pressure that adheres the tissue to the cannula wall. By performing a rotating movement between the fingers while gently moving between the uterine fundus and the internal cervical os, optimal contact with the endometrial wall is achieved and a representative sample is obtained in about 30 seconds.
- Atraumatic rounded tip: facilitates insertion and minimises discomfort.
- Centimetre scale from 1 to 7 cm: allows insertion depth to be controlled during the manoeuvre.
- Manual vacuum with internal plunger: total autonomy, without pump or syringes.
- No dilation or cervical traction: maximum patient acceptance and lower risk of discomfort.
- One lateral opening: focal suction ideal for cytological sampling and postcoital tests.
Technical specifications
Technical data sheet
| Reference | 720196 |
| Product type | Cornier-type endometrial suction cannula (Rampipella) |
| Tip configuration | One lateral opening at the end |
| Material | Medical-grade polypropylene (PP) |
| Length | 24.5 cm |
| Outer diameter | 3.1 mm (nominal Ø 3 mm) |
| Centimetre scale | 1 to 7 cm (resolution of 1 cm) |
| Suction system | Plunger or internal manual vacuum mandrel |
| Sterility | Sterile, sterilised by ethylene oxide (EO) |
| Use | Single-use (disposable), not re-sterilisable |
| Validity | 5 years |
| Intended use | Endometrial sampling by suction (cytology) and postcoital tests |
| Classification | Medical device with CE marking, Regulation (EU) 2017/745 |
| Presentation | Box of 25 units |
Family range
| Reference | Configuration | Length | Outer Ø | Presentation |
| 720196 | One opening (Rampipella) | 24.5 cm | 3.1 mm | Box of 25 units |
| 0438107 | Two openings (Rampipella) | 24.5 cm | 3.1 mm | Box of 25 units |
Equivalences and cross-references
There is no cross-reference equivalence table validated by the manufacturer for this reference. The alternatives from other manufacturers listed below correspond to the same product category —sterile single-use endometrial suction cannula with manual vacuum and an external diameter of 3.1 mm— and may be used as a reference in purchasing and approval processes, subject to technical verification.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| CooperSurgical | Pipelle – Endometrial Suction Curette (Ø 3.1 mm) | 8200 | Comparable by category (not interchangeable 1:1) | Same diameter (3.1 mm), sterile, single-use, box of 25 units; verified in the manufacturer’s official catalogue and GUDID (DI 00888937003475). Usable length not specified in the GUDID record; confirm in its IFU. |
| MedGyn | Endometrial pipette 3.1 mm (single-orifice design) | 022721 | Comparable by category (not interchangeable 1:1) | Ø 3.1 mm, cannula length 23.5 cm, sterile, single-use, box of 25 units; verified in GUDID (DI M803022721) and on the manufacturer’s official website. |
| Laboratoires CCD | Cornier Pipelle 3.1 mm (Pipelle) | 1103000 | Comparable by category (not interchangeable 1:1) | Same clinical family (Cornier Pipelle), Ø 0.31 cm, length 23.5 cm, sterile; verified in GUDID (DI 03700111400719). |
| GIMA | Sterile Pipella with 1 orifice | 29826 | Comparable by category (not interchangeable 1:1) | Same indication, external Ø 3.1 mm, cannula 23.5 cm and handle 26.5 cm; usual presentation of 100 units (boxes of 25 on request depending on distributor). Verified in the manufacturer’s official manual and catalogues of authorised distributors. |
| CooperSurgical (Wallach) | Endocell – Endometrial Cell Sampler (Ø 3.1 mm) | 908016 | Comparable by category (not interchangeable 1:1) | Flexible sheath 24.3 cm and Ø 3.1 mm, rounded tip, sterile, single-use; presentation in a box of 35 units. Verified on the manufacturer’s official website and authorised distributors. |
Note: there is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. The cited references have been verified in public sources (manufacturers’ official websites and GUDID) or in catalogues of authorised distributors as support; none is interchangeable 1:1 without prior verification of dimensions, material and marking of the specific batch.
Selection tips and variants of interest
- 1 orifice vs 2 orifices: the single-orifice version (ref. 720196) offers focal suction, particularly indicated for cytological samples and screening in the consultation; the two-orifice version (ref. 0438107) distributes suction better when a wider sample is required.
- Depth control: it is recommended to check the uterine depth beforehand with a hysterometer and respect the centimetre scale from 1 to 7 cm during insertion to avoid exceeding the uterine fundus.
- Sample handling: after collection, cut the tip and push the piston to deposit the sample in the container with histological fixative; dispose of the device after use.
- Kit compatibility: at Cahnos the complete suction sampling solution is available, such as the Citovac 4 kit (ref. 0438023, includes cannula, syringe, tube and label), and intrauterine suction cannulas (ref. CARRIC) for procedures with a suction unit.
- Storage: keep the packaging intact in a cool, dry place; use before the indicated expiry date and only if the packaging shows no damage.
- Hospital purchasing: for volume needs and tender processes, contact our commercial team for special quantity conditions.




Reviews
There are no reviews yet.