Description
Introduction
The 1-orifice Pipella (ref. 29826) is the ideal solution for endometrial cytological sampling in the gynaecology clinic. It is a disposable, sterile cannula that allows routine endometrial screening to be performed in a simple, fast and practically painless way for the patient, without the need for dilation or traction of the cervix. Its presentation in a box of 100 units makes it an optimal option for clinics, health centres and gynaecology services with high turnover.
Technical explanation of the device
The Pipella is a minimally invasive endometrial suction device: it is introduced through the cervical canal into the uterine cavity and, by retracting the internal plunger, a negative pressure is generated that allows endometrial cells to be captured through the distal lateral orifice for subsequent cytological analysis.
Its single-orifice configuration provides focal suction, particularly indicated for cytological sampling and endometrial screening in the clinic. By avoiding cervical dilation and traction, discomfort and the risk of trauma are minimised, with excellent patient tolerance. Being a sterile, single-use product, reprocessing and the risk of cross-contamination are completely eliminated.
Technical specifications
Orifice: Ø 2.0-2.5 mm
Outer diameter: 3.1 mm
Cannula length: 23.5 cm
Handle length: 26.5 cm
Multilingual packaging and manual: GB, FR, IT, ES, PT, DE, NL, DK, SE, NO, FI, LT, LV, EE, PL, CZ, SK, HU, SI, HR, RO, BG, GR and Arabic.
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 29826 |
| Sales unit | Box of 100 units |
| Device type | Medical device (Medical device) |
| Device class | I S |
| CND | U0899 |
| EAN | 8023279298260 |
Equivalences and cross-references
This Pipella falls into the category of sterile, single-use endometrial suction cannulas with manual vacuum and an outer diameter of 3.1 mm. The references listed below are comparable by category and not interchangeable 1:1 without prior technical verification of dimensions, material and presentation:
| Manufacturer | Device | Reference |
|---|---|---|
| CooperSurgical | Pipelle – endometrial suction curette (Ø 3.1 mm) | 8200 |
| MedGyn | Endometrial pipette 3.1 mm (one orifice) | 022721 |
| Laboratoires CCD | Pipelle de Cornier 3.1 mm | 1103000 |
| CooperSurgical (Wallach) | Endocell – endometrial cell sampler (Ø 3.1 mm) | 908016 |
| RI.MOS. (GINRAM) | Cornier endometrial suction cannula (Rampipella) with 1 orifice | 720196 |
Consult our technical department to confirm equivalences in approval or tendering processes.
Selection tips and variants of interest
For cytological endometrial screening in the clinic, the 1-orifice version offers very well-tolerated focal suction. If a wider sample or distribution of suction is required, consider 2-orifice variants from the same clinical family. In stenotic cervices or menopausal patients, finer-gauge devices (Ø 2.4 mm) are preferable.
It is recommended to check the uterine depth beforehand with a hysterometer, place the sample obtained in a container with histological fixative and dispose of the device after use. For volume purchases and hospital tendering processes, consult our sales team for special conditions.