Description
Sterile amniocentesis needle 21G x 80 mm – Ref. 770226
The sterile 21G x 80 mm amniocentesis needle is a single-use medical device intended for obstetric procedures to obtain amniotic fluid in prenatal diagnostic settings. It is supplied in a box of 25 units, ensuring availability and optimal hygiene and safety conditions in each procedure, for both gynaecology clinics and hospital obstetric services.
Technical explanation of the procedure
Amniocentesis is a diagnostic technique involving ultrasound-guided transabdominal puncture of the amniotic sac to obtain a sample of amniotic fluid. This sample is commonly used for karyotyping studies (detection of chromosomal abnormalities such as Down syndrome), determination of fetal sex, study of inherited metabolic disorders, assessment of Rh isoimmunisation or fetal lung maturity.
The 21G (0.80 mm) gauge offers an appropriate balance between ease of aspiration and minimal tissue trauma, while the 80 mm length is ideal for transabdominal access in patients with little adipose panniculus. As a sterile, single-use product, the risk of cross-contamination between patients is eliminated. The procedure must always be performed by qualified personnel under ultrasound guidance, with the patient properly informed and after assessing the contraindications (active vaginal bleeding or coagulation disorders).
Technical specifications
| Specification | Detail |
|---|---|
| Product | Sterile amniocentesis needle |
| Gauge | 21G (nominal outer diameter 0.80 mm) |
| Length | 80 mm |
| Sterility | Sterile, single-use product |
| Presentation | Box of 25 units |
| Indication | Amniocentesis and prenatal diagnosis (transabdominal puncture guided by ultrasound imaging) |
| Reference | SKU 770226 |
Equivalences and cross-references
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before using it in tenders. Below are references from other manufacturers verified in official catalogues or regulatory databases, comparable by category but not interchangeable 1:1 because they differ in length, tip, connector or presence of a side port:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cook Medical | Disposable EchoTip® Amniocentesis Needle | J-DAN-211501 (21G x 15 cm); J-DAN-211502 (21G x 15 cm with side port) | Comparable by category (not interchangeable 1:1) | Length 150 mm (not 80 mm); EchoTip echogenic tip; Luer connector; box of 10 units. |
| Cook Medical | Disposable EchoTip® Amniocentesis Needle (with side port) | J-DAN-210902 (21G x 9 cm) | Comparable by category (not interchangeable 1:1) | Length 90 mm (close to 80 mm, not identical); distal side port for aspiration; echogenic tip. |
| CooperSurgical (Wallace®) | Wallace® Amniocentesis Needles | 12021 (21G x 120 mm); 15021 (21G x 150 mm); 9022 (22G x 90 mm) | Comparable by category (not interchangeable 1:1) | Verified in the manufacturer’s IFU; stainless steel, self-positioning stylet, distal echogenic marker and Luer connection; longer lengths. |
| M.D.L. S.r.l. | Amnio (ultra-sharp Chiba-type tip 16°) | PBU2115 (21G x 15 cm); PBU2215 (22G x 15 cm) | Comparable by category (not interchangeable 1:1) | Verified in EUDAMED/GUDID; echogenic marker, centimetre markings, sliding stop and Luer Lock connection; length 150 mm. |
References 770201, 770212, 770222, 770224, 770228, 770202, 770223, 770227, 770229 and 770232 from Cahnos complete the same family in 20G, 21G and 22G gauges with lengths from 80 to 180 mm.
Selection tips and variants of interest
To choose the appropriate amniocentesis needle, consider the gauge and length according to the access route and the patient’s body habitus: the 21G x 80 mm is a very manageable short-access option; if greater depth is required, the 100, 120, 150 or 180 mm versions of the same family can be used. The 20G (0.90 mm) gauge facilitates greater aspiration flow and the 22G (0.70 mm) further reduces tissue trauma.
In patients with a larger adipose panniculus, a length greater than 80 mm is recommended to safely reach the amniotic cavity. Always check the expiry date and the integrity of the individual package before use, do not reuse or re-sterilise the product, and manage the used needle as hazardous healthcare waste. For tender requirements or institutional volumes, contact our commercial team for special conditions.