Sterile Amniocentesis Needle 21G x 150 mm (0.80 x 150) with Echogenic Stylet and Luer Lock | Box 25 units | Ref. 770202

217,00 €

Sterile amniocentesis needle 21G x 150 mm (0.80 x 150 mm), single-use and individually packaged, designed for ultrasound-guided transabdominal puncture of the amniotic sac in prenatal diagnosis (weeks 15-18 of gestation). It incorporates a stylet with an echo-marked tip detectable by ultrasound, an adjustable sliding depth stop and a female luer lock connector compatible with 20 mL syringes. Sterilised by ethylene oxide (EtO). Economical presentation in box of 25 units with per-unit traceability, ideal for gynaecology clinics, fetal medicine units and hospital obstetrics services. Reference 770202 (AMNIORAM range), available with immediate delivery.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
770202

Description

Precision and safety in prenatal diagnosis

The sterile amniocentesis needle 21G x 150 mm (ref. 770202) is the reference instrument for transabdominal collection of amniotic fluid in gynaecology and obstetrics clinics, fetal medicine units and prenatal diagnostic centres. It is supplied in a box of 25 units with individual sterile packaging, ensuring availability, traceability and optimal hygiene conditions for each puncture. It belongs to the AMNIORAM range, available in 11 sizes to cover all access routes and body types.

Single-use medical device, sterile and with CE marking, designed for professionals who demand reliability, precision and regulatory compliance in every diagnostic procedure.

Technical explanation of the procedure

Amniocentesis is a diagnostic technique that involves transabdominal puncture of the amniotic sac, guided by ultrasound imaging, to extract a sample of amniotic fluid. It is usually performed between weeks 15 and 18 of gestation for prenatal detection of chromosomal abnormalities (karyotype), cytogenetic and biochemical studies, determination of fetal sex or assessment of lung maturity.

This needle is designed for ultrasound-guided insertion: the stylet incorporates an echo-marked tip that allows the trajectory to be visualised in real time and provides rigidity to the cannula, avoiding the coring effect. The adjustable sliding stop mechanically limits the insertion depth and the female luer lock connector ensures secure attachment of a standard syringe (20 cc recommended) for sample collection without leaks or disconnections. The 21G gauge (0.80 mm outer diameter) offers an optimal balance between ease of aspiration and minimal tissue trauma, with atraumatic penetration. The procedure must always be performed by qualified personnel, under ultrasound control and after assessing the contraindications (active vaginal bleeding or coagulation disorders). Check the integrity and expiry date of the individual packaging before each use; it is a single-use product, not re-sterilisable.

Technical specifications

Product Sterile amniocentesis needle, single-use
Gauge 21G (nominal outer diameter 0.80 mm)
Length 150 mm
Tip type Atraumatic sharpening; stylet with echo-marked tip (detectable by ultrasound)
Depth stop Adjustable sliding stop on the cannula
Connection Female luer lock connector (compatible with 20 cc syringes)
Gauge coding Green (international identification code, 21G)
Material Stainless steel cannula with stylet
Sterility Sterile, individual packaging, sterilised by ethylene oxide (EtO)
Use Single-use, not re-sterilisable
Presentation Box of 25 units with individual sterile packaging
Indication Transabdominal amniocentesis and prenatal diagnosis (weeks 15-18)
Classification Medical device Class IIa, CE marking
Reference 770202 (AMNIORAM range)

Cahnos range of amniocentesis needles (box of 25 units):

Reference Gauge Length
770212 20G 80 mm
770228 20G 100 mm
770222 20G 120 mm
770224 20G 150 mm
770201 20G 180 mm
770226 21G 80 mm
770227 21G 100 mm
770223 21G 120 mm
770202 21G 150 mm (this product)
770229 21G 180 mm
770232 22G 150 mm
770233 22G 90 mm

Equivalences and cross-references

There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. Below are references from other manufacturers verified in official catalogues, IFUs or regulatory databases, comparable by category but not interchangeable 1:1 because they differ in tip design, connector or presentation:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
GIMA (Italy) Amniocentesis Needle 21G x 150 mm, sterile 29641 Comparable by category (not interchangeable 1:1) Same dimensions (21G x 150 mm) and presentation (box of 25 units); stylet with echo-marked tip, adjustable stop and female luer lock connector; same ultrasound-guided insertion mechanism; verified in the GIMA datasheet and manual (EAN of the 120 mm code: 8023279296402)
Cook Medical Disposable EchoTip® Amniocentesis Needle G16299 (J-DAN-211501) Comparable by category (not interchangeable 1:1) 21G x 15 cm (150 mm) without side port; echogenic EchoTip tip; presentation in box of 10 units; verified in Cook catalogue and GUDID records/authorised distributor
CooperSurgical (Wallace®) Wallace® Amniocentesis Needles 15021 Comparable by category (not interchangeable 1:1) 21G x 150 mm; stainless steel, self-positioning stylet, distal echogenic mark and Luer connection; box of 10 units; verified in official CooperSurgical IFU

Other homologous families on the market (M.D.L. Amnio series with Chiba-type tip, Medax AMNIOX, Laboratoire CCD for amniocentesis and cordocentesis) must be verified datasheet by datasheet (gauge, length, tip type, connector and presentation) before being considered an alternative; no reference from another manufacturer should be taken as interchangeable 1:1 without prior technical validation from the corresponding department.

Selection tips and variants of interest

Choice of length: the 150 mm version (ref. 770202) covers patients with medium to high abdominal wall thickness; for more superficial accesses, the 80 mm (770226), 100 mm (770227) or 120 mm (770223) versions can be used, and if greater depth is anticipated, the 180 mm (770229) version from the same family.

Gauge: the 21G version (0.80 mm) offers fine and atraumatic punctures; the 20G (0.90 mm) facilitates the flow of aspiration in larger volume samples (also available in 150 mm, ref. 770224) and the 22G (0.70 mm) further minimises tissue trauma (150 mm, ref. 770232).

Good practices: always check the expiry date and integrity of the individual packaging before use, confirm the ultrasound visualisation of the stylet tip before starting the puncture and manage the used needle as hazardous healthcare waste in accordance with current regulations. Single-use product, not re-sterilisable. For tender needs or institutional volumes, contact our commercial team for special conditions.

Additional information

Gauge

21G (0.80 mm outer diameter)

Tip type

Atraumatic sharp with echo-marked stylet tip

Depth stop

Adjustable sliding stop on the cannula

Connection

Female luer lock connector (20 cc syringe recommended)

Colour coding

Green (international code 21G)

Material

Stainless steel cannula with stylet

Sterilisation

Ethylene oxide (EtO)

Use

Single-use (disposable), not re-sterilisable

Presentation

Box of 25 units with individual sterile packaging

Indications

Transabdominal amniocentesis and prenatal diagnosis (weeks 15-18)

Regulatory classification

Medical device Class IIa, CE marking

Reference

770202

Classification

Medical device Class IIa, CE marking

Product line

AMNIORAM

Diametro mm

0.8 mm

Longitud

15 cm

Reviews

There are no reviews yet.

Be the first to review “Sterile Amniocentesis Needle 21G x 150 mm (0.80 x 150) with Echogenic Stylet and Luer Lock | Box 25 units | Ref. 770202”

Your email address will not be published. Required fields are marked *