We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Sterile Amniocentesis Needle 20G x 150 mm with Echogenic Stylet and Luer Lock Connector | Box of 25 units | Ref. 29638

370,50 €

Sterile amniocentesis needle for single use, gauge 20 G (0.9 mm) and length 150 mm, designed for transabdominal collection of amniotic fluid under ultrasound guidance in prenatal diagnosis (weeks 15-18). It incorporates a stylet with ultrasound-detectable tip for ultrasound-guided insertion, adjustable sliding depth stop and female Luer Lock connector for leak-free sample collection with a syringe. Manufactured (Italy), it is supplied sterile in individual packaging within a box of 25 units. Medical device Class IIa with CE marking, indicated for gynaecology clinics, fetal medicine units and obstetrics services.

Sales unit: caja de 25
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM29638

Description

Precision and safety in prenatal diagnosis

The sterile amniocentesis needle 20 G x 150 mm (ref. 29638) is the reference instrument for transabdominal collection of amniotic fluid in gynaecology and obstetrics clinics, fetal medicine units and prenatal diagnostic centres. Manufactured in Italy, it is supplied in a box of 25 units with individual sterile packaging, ensuring availability, traceability and optimal hygiene conditions in each puncture. It is a single-use, sterile medical device with CE marking (Class IIa), designed for professionals who demand reliability, precision and regulatory compliance in every diagnostic procedure.

Technical explanation of the procedure

Amniocentesis is a prenatal diagnostic technique that involves transabdominal puncture of the amniotic sac, guided by ultrasound imaging, to extract a small sample of amniotic fluid. It is usually performed between weeks 15 and 18 of gestation for the study of the fetal karyotype (detection of genetic disorders), as well as for cytogenetic and biochemical studies of the amniotic fluid.

The precise sharpening of the needle facilitates easy and atraumatic penetration. The stylet incorporates an ultrasound-detectable tip that allows real-time ultrasound-guided insertion and is colour-coded for immediate identification of the gauge (yellow = 20G). The adjustable sliding stop allows the insertion depth to be mechanically fixed, while the female Luer Lock connector ensures secure attachment of the syringe for sample collection without leaks or disconnections. The procedure must always be performed by qualified personnel under ultrasound guidance, with the patient properly informed.

Technical specifications

Specifications verified against the manufacturer’s official catalogue (Product_DB):

Manufacturer GIMA
Gauge 20 G (0.9 mm outer diameter)
Length 150 mm
Mandrel Ultrasound-detectable tip (echo-marked), with colour code
Depth stop Adjustable slider
Connection Female Luer Lock connector
Colour code Yellow (international identification of 20G calibre)
Sterility Sterile, single-use, individually packaged
Indication Transabdominal amniocentesis and prenatal diagnosis (weeks 15-18)
Origin Made in Italy
Sales unit Box of 25 units
Device type Medical device
Device class II A
CND A010204
EAN 8023279296389
Manufacturer reference 29638
SKU Cahnos GM29638

Equivalences and cross-references

There is no equivalence table validated by the manufacturer for this reference; the references indicated below are functional comparisons verified against official catalogues and regulatory databases (GUDID/FDA and product data sheets), comparable by category but not interchangeable 1:1 because they differ in tip type, connector or presentation. Before using them as a substitute in a tender or protocol, consult the technical department to validate gauge, length, materials and regulatory classification.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Observations
(Italy) Amniocentesis Needles (Aghi per Amniocentesi) 29638 (GM29638) Product reference 20 G x 150 mm; stylet with echo-marked tip, sliding stop and female Luer Lock connector; box of 25 units; Class IIa.
Cahnos (AMNIORAM range) AMNIORAM amniocentesis needle 770224 Comparable by category (not interchangeable 1:1) 20 G x 150 mm; same construction and ultrasound-guided insertion mechanics; box of 25 units.
RI.MOS (Italy) AMNIOCENT 772004 Comparable by category (not interchangeable 1:1) 20 G x 150 mm with centimetre cannula; same size and presentation; the graduated cannula differs.
Cook Medical Disposable EchoTip® Amniocentesis Needle G16289 (J-DAN-201501) Comparable by category (not interchangeable 1:1) 20 G x 15 cm without side port; EchoTip echogenic tip; box of 10 units; GUDID/FDA registration.
Cook Medical Disposable EchoTip® (with side port) G16290 (J-DAN-201502) Comparable by category (not interchangeable 1:1) 20 G x 15 cm with distal side port for suction; EchoTip echogenic tip; box of 10 units.
BPB Medica (Biopsybell) GAMMA™ GM2015EC Comparable by category (not interchangeable 1:1) 20 G x 15 cm; modified Chiba-type bevel, internal echogenic marker, centimetre markings and Luer Lock connection; box of 20 units.
CooperSurgical (Wallace®) Wallace® Amniocentesis Needles 15021 Different gauge 21 G x 150 mm; stainless steel, self-positioning stylet and distal echogenic mark.
M.D.L. S.r.l. Amnio (Chiba-type tip) PBU2115 / PBU2215 Different gauge 21 G/22 G x 15 cm; echogenic marker, centimetre markings and sliding stop.

Selection tips and variants of interest

Choice of length: the 150 mm version is the most versatile in the range and covers most patients with an average body habitus. If a greater abdominal wall thickness or deeper access is anticipated, consider longer versions (180 mm); for patients with less thickness, the 80, 100 or 120 mm versions of the same family.

Within the amniocentesis needle range, ref. 29636 corresponds to 20 G x 100 mm, 29637 to 20 G x 120 mm, 29639 to 20 G x 180 mm and 29641 to 21 G x 150 mm, all in boxes of 25 units. For protocols requiring a graduated cannula, consult the variants with centimetre cannula of the AMNIOCENT family.

Gauge: the 20G (0.9 mm) offers a good balance between suction flow and minimal tissue trauma; the 21G (0.8 mm) reduces the outer diameter for finer and more atraumatic punctures.

Good practices: always verify the integrity and expiry date of the individual packaging before each use, confirm ultrasound visualisation of the stylet tip before starting the puncture, and manage the used needle as hazardous healthcare waste in accordance with current regulations. Single-use product, not re-sterilisable. For volume orders, public tenders or technical documentation, contact our commercial team.

Additional information

Manufacturer reference

29638

EAN

8023279296389

Gauge

20 G (0.9 mm outer diameter)

Mandrel

Ultrasound-detectable tip (echo-marked), with colour code

Depth stop

Adjustable slider

Connection

Female Luer Lock connector

Colour code

Yellow (20 G)

Sterilisation

Sterile, single-use, individually packaged

Presentation

Box of 25 units

Classification

Medical device Class IIa, with CE marking

CND code

A010204

Indications

Transabdominal amniocentesis and prenatal diagnosis (weeks 15-18)

Origin

Made in Italy

Presentacion

Box of 25

Tipo dispositivo

Medical device

Clase sanitaria

II a

Longitud

15 cm

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Sterile Amniocentesis Needle 20G x 150 mm with Echogenic Stylet and Luer Lock Connector | Box of 25 units | Ref. 29638”

Your email address will not be published. Required fields are marked *