We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Sterile Amniocentesis Needle 20G x 100 mm (0.9 x 100) with Echogenic Stylet and Luer Lock | Ref. 29636 | Box of 25 units

370,50 €

Sterile amniocentesis needle 20G x 100 mm (ref. 29636), single-use and individually packaged, designed for ultrasound-guided transabdominal puncture of the amniotic sac in prenatal diagnosis (weeks 15-18 of gestation). It incorporates a stylet with echo-marked tip detectable by ultrasound, adjustable sliding depth stop and female luer lock connector compatible with standard 20 mL syringes. Sterilised by ethylene oxide (EtO), with yellow gauge colour coding. Supplied in a box of 25 units with per-unit traceability. Made in Italy.

Sales unit: caja de 25
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM29636

Description

Precision and safety in prenatal diagnosis

The sterile amniocentesis needle 20G x 100 mm (ref. 29636) is the reference instrument for transabdominal collection of amniotic fluid in gynaecology and obstetrics clinics, fetal medicine units and prenatal diagnostic centres. Made in Italy, it is supplied in a box of 25 units with individual sterile packaging, ensuring availability, traceability and optimal hygiene conditions in each puncture.

Medical device for single use, sterile and with CE marking (Class IIa), designed for professionals who demand reliability, precision and regulatory compliance in every diagnostic procedure. For large orders you can request a quote: contact our sales team for terms and delivery times.

Technical explanation of the procedure

Amniocentesis is a prenatal diagnostic technique that involves transabdominal puncture of the amniotic sac, guided by ultrasound imaging, to extract a small sample of amniotic fluid. It is usually performed between weeks 15 and 18 of gestation for fetal karyotyping studies (detection of chromosomal abnormalities), cytogenetic and biochemical analyses, fetal sex determination or assessment of lung maturity.

The needle is introduced following the path previously detected by ultrasound: the stylet incorporates an echo-marked tip, detectable by ultrasound, which allows the trajectory to be visualised in real time and provides rigidity to the cannula, avoiding the coring effect. The adjustable sliding stop mechanically fixes the maximum insertion depth, while the female luer lock connector ensures secure attachment of the syringe (usually 20 mL) for sample collection without leaks or disconnections. The 20G gauge (0.9 mm outer diameter) offers a good balance between ease of suction and minimal tissue trauma, with an atraumatic sharp point for clean, controlled penetration. The colour coding of the hub immediately identifies the gauge (yellow = 20G). The procedure must always be performed by qualified personnel, under ultrasound guidance and after assessing the contraindications (active vaginal bleeding or coagulation disorders). Check the integrity and expiry date of the individual packaging before each use; it is a single-use product, not re-sterilisable.

Technical specifications

Specification Detail
Product Sterile amniocentesis needle, single-use
Gauge 20G (0.9 mm nominal outer diameter)
Length 100 mm
Tip type Atraumatic sharpening; stylet with echo-marked tip (detectable by ultrasound)
Depth stop Adjustable slider on the cannula
Connection Female luer lock connector (compatible with standard 20 mL syringes)
Gauge coding Yellow colour (international colour code 20G)
Material Stainless steel cannula with stylet
Sterility Sterile, individual packaging, not re-sterilisable
Sterilisation Ethylene oxide (EtO)
Indication Transabdominal amniocentesis and prenatal diagnosis (weeks 15-18)
Presentation Box of 25 units with individual sterile packaging

Product data

Manufacturer GIMA
Manufacturer reference 29636
Sales unit box of 25 pcs
Device type Medical device
Device class II A
CND A010204
EAN 8023279296365
Origin Made in Italy

Available references

Reference Gauge Length
29636 20G 100 mm
29637 20G 120 mm
29638 20G 150 mm
29639 20G 180 mm
29640 21G 120 mm
29641 21G 150 mm

Equivalences and cross-references

There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tenders. Below are references verified in the official catalogue or regulatory databases, comparable by category but not interchangeable 1:1 as they differ in brand, tip design, connector or presentation:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
Cahnos (RI.MOS. AMNIORAM) Amniocentesis needle 20G x 100 mm 770228 Comparable by category (not interchangeable 1:1) Same dimensions (20G x 100 mm) and presentation (box of 25 units); stylet with echo-marked tip, adjustable stop and female luer lock connector; Class IIa, latex-free and DEHP-free
(Italy) Amniocentesis Needles 20G 29637 / 29638 / 29639 Variants of the same family Same construction and ultrasound-guided insertion mechanics, with longer lengths (120, 150 and 180 mm); box of 25 units
Cook Medical Disposable EchoTip® Amniocentesis Needle G16287 (J-DAN-201201) Comparable by category (not interchangeable 1:1) 20G x 12 cm (120 mm); EchoTip echogenic tip; standard Luer connector; box of 10 units; verified in GUDID (FDA)
BPB Medica GAMMA™ (modified Chiba-type tip) GM2012EC Comparable by category (not interchangeable 1:1) 20G x 12 cm; internal echogenic marker, centimetre markings, sliding stop and luer lock connection; box of 20 units

Other homologous families on the market (M.D.L. Amnio series, Laboratoire CCD, CooperSurgical/Wallace®) must be verified sheet by sheet (gauge, length, tip type, connector and presentation) before being considered an alternative. No reference from another manufacturer should be taken as interchangeable 1:1 without prior technical validation from the relevant department.

Selection tips and variants of interest

Choice of length: the 100 mm version (ref. 29636) is ideal for patients with an average abdominal wall thickness. If greater depth is expected due to a larger body habitus or posterior uterine position, choose the 120 mm (29637), 150 mm (29638) or 180 mm (29639) versions of the same 20G gauge; for more superficial access, consider smaller sizes in the range.

Gauge: the 20G (0.9 mm) facilitates smooth suction in larger-volume samples; the 21G (0.8 mm) offers finer, more atraumatic punctures (available in 120 and 150 mm).

Good practice: always check the integrity of the individual packaging and the expiry date before each use, confirm ultrasound visualisation of the stylet tip before starting the puncture, check the compatibility of the luer lock connector with the 20 mL syringe and manage the used needle as hazardous medical waste in accordance with current regulations. Single-use product, not re-sterilisable. For tender requirements, institutional volumes or technical documentation (IFU, declaration of conformity), contact our sales department.

Additional information

Manufacturer reference

29636

Gauge

20G (0.9 mm outer diameter)

Tip type

Atraumatic sharpening; stylet with echo-marked tip (detectable by ultrasound)

Depth stop

Adjustable slider on the cannula

Connection

Female Luer Lock connector (compatible with 20 mL syringes)

Colour code

Yellow (20G)

Material

Stainless steel cannula with stylet

Sterilisation

Ethylene oxide (EtO)

Use

Single-use, not re-sterilisable

Presentation

Box of 25 units with individual sterile packaging

Indications

Transabdominal amniocentesis and prenatal diagnosis (weeks 15-18)

Regulatory classification

Medical device Class IIa, CE marking

CND code

A010204

EAN

8023279296365

Origin

Made in Italy

Presentacion

Box of 25

Tipo dispositivo

Medical device

Clase sanitaria

II a

Longitud

10 cm

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Sterile Amniocentesis Needle 20G x 100 mm (0.9 x 100) with Echogenic Stylet and Luer Lock | Ref. 29636 | Box of 25 units”

Your email address will not be published. Required fields are marked *