We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

VitaSprings® Membrane Oxygenator (MicroPort® Surgical) for extracorporeal circulation – Models MO-L, MO-M and MO-S for adult, paediatric and infant

Price on request

VitaSprings® is a membrane oxygenation system from MicroPort® Surgical, indicated for gas–blood exchange during open-heart surgery in adult, paediatric and infant patients.

  • Maximum blood flow: 6 L/min (adult) · 2.5 L/min (paediatric) · 1.5 L/min (infant)
  • Parallel arrangement of the gas and heat exchanger: compact structure and low priming volume
  • Rotating 360° inlet panel for greater flexibility during the procedure
  • Cardiotomy reservoir from 2,000 to 4,000 ml depending on model
  • Presentation: 2 units/box

International shipping. Import duties and taxes are payable by the recipient.

Reference
MPS-VS

Description

Adult, paediatric and infant · Low priming volume · 360° rotating inlet panel

1. Product Introduction

The membrane oxygenation system VitaSprings® from MicroPort® Surgical is the reference solution for gas–blood exchange during open-heart surgery with extracorporeal circulation (ECC). A single family with three models (MO-L, MO-M and MO-S) covering the full range of adult, paediatric and infant patients, with maximum flow rates of 6, 2.5 and 1.5 L/min respectively. Its compact design, low priming volume and 360° rotating inlet panel make it a safe and convenient choice for perfusionists and cardiac surgeons. Medical device with CE marking, in accordance with Regulation (EU) 2017/745.

2. Technical explanation of the equipment

The VitaSprings® is a membrane oxygenator that performs the pulmonary function during cardiopulmonary bypass: it oxygenates venous blood and removes carbon dioxide through a high-efficiency hollow-fibre membrane, with low blood trauma. The gas exchanger and the heat exchanger are arranged in parallel, providing a compact structure, clear blood flow, effective de-airing and a reduced priming volume. It incorporates an integrated cardiotomy reservoir with filtered inlets in three sizes and a 360° rotating inlet panel that optimises flexibility and comfort during the procedure. The PET heat exchange membrane ensures high thermal efficiency with uniform temperature gradients, and the recommended air-to-blood ratio is 1:1.

3. Technical Specifications

Product Description

Description Membrane oxygenation system
Family VitaSprings®
Function Gas–blood exchange during open-heart surgery
Models MO-L (adult) · MO-M (paediatric) · MO-S (infant)
Maximum blood flow 6 · 2.5 · 1.5 L/min depending on model
Cardiotomy reservoir 2,000 – 4,000 ml depending on model
Minimum working volume 150 ml
Configuration Gas and heat exchanger in parallel arrangement
Presentation 2 units per box
Manufacturer MicroPort® Surgical

Technical features

Maximum blood flow Adult 6 L/min · Paediatric 2.5 L/min · Infant 1.5 L/min
Cardiotomy reservoir volume 4,000 · 3,000 · 2,000 ml
Minimum working volume 150 ml in all three models
Priming of the gas exchange chamber 160 · 80 · 50 ml
Priming of the heat exchange chamber 80 · 50 · 40 ml
Gas exchange membrane surface area 2 · 1.2 · 0.7 m²
Heat exchange membrane surface area 0.6 · 0.4 · 0.2 m²
Recommended air-to-blood ratio 1:1
Venous blood inlet Ø12 mm · Ø10 mm · Ø6 mm
Venous blood outlet Ø10 mm · Ø10 mm · Ø6 mm
Filtered cardiotomy inlets Ø6 / 8 / 10 mm
Heat exchanger inlet Ø10 mm · Ø10 mm · Ø6 mm
Oxygenator inlet Ø10 mm · Ø10 mm · Ø6 mm
Gas inlet Ø6 mm
Recirculation port Ø6 mm
Water inlet / outlet Ø16 mm

Performance and safety (factory data)

Oxygen transfer Increase ≥ 45 ml at maximum blood flow
Blood circuit pressure drop 130 mmHg
Blood trauma Increase in plasma free haemoglobin < 20 mg/h; platelet reduction < 20 %/h and leucocyte reduction < 20 %/h under standard bypass conditions
Oxygenation membrane High-efficiency hollow fibres with low blood trauma
Heat exchange membrane PET, high thermal efficiency and uniform gradients
Suction ports Six ports in three sizes with 360° rotating design

References and ordering information

Reference Model Maximum flow rate Presentation
MO-L Adult 6 L/min 2 units/box
MO-M Paediatric 2.5 L/min 2 units/box
MO-S Children 1.5 L/min 2 units/box

Regulations and documentation

Product Medical device — exclusive use under medical prescription
European Regulation Regulation (EU) 2017/745 on medical devices
National regulations Royal Decree 192/2023, regulating medical devices
CE marking Attached as a separate document
Documentation Indications, contraindications, warnings and instructions for use in the instructions for use accompanying the product

4. Equivalences and Cross-References

The VitaSprings® system is a family of membrane oxygenators with an integrated cardiotomy reservoir, functionally comparable to other single-use membrane oxygenator ranges used in ECC, such as the Affinity® family from Medtronic, CAPIOX® from Terumo, Inspire from LivaNova or Quadrox-i from Getinge/Maquet in their adult, paediatric and infant versions. In the Cahnos catalogue, the product is directly complemented by the VitaSprings® GoPro family (refs. HRMO-70F, HRMO-50F and HRMO-30F), a membrane oxygenator with an integrated 38 µm arterial filter, automatic vortex purge and helical flow, indicated when arterial filtration is to be integrated into the oxygenator itself. MicroPort® Surgical (SleekFlow®) extracorporeal circuit cannulas complete the perfusion set for ECC procedures.

5. Selection tips and variants of interest

  • MO-L (adult): maximum flow rate of 6 L/min, cardiotomy reservoir of 4,000 ml and gas chamber priming of 160 ml. Indicated for adult patients with large body surface areas and full bypass flow rates.
  • MO-M (paediatric): maximum flow rate of 2.5 L/min, reservoir of 3,000 ml and priming of 80 ml. For paediatric patients with intermediate requirements.
  • MO-S (infant): maximum flow rate of 1.5 L/min, reservoir of 2,000 ml and priming of 50 ml. For infant patients where haemodilution must be minimised to the greatest extent.
  • Select the model according to the patient’s weight and expected blood flow; the low priming volume reduces haemodilution and the need for transfusions.
  • If an integrated arterial filter, automatic purge and helical flow are required, consider the complementary family VitaSprings® GoPro (HRMO-70F/50F/30F).
  • Check the compatibility of the connectors (Ø6–16 mm) with the extracorporeal circulation circuit and the perfusion machine before use. Presentation in a box of 2 units.

Additional information

Description

Membrane oxygenation system

Family

VitaSprings®

Manufacturer

MicroPort® Surgical

Models

MO-L (adult) · MO-M (paediatric) · MO-S (infant)

Function

Gas-blood exchange during open-heart surgery

Maximum blood flow

6 / 2.5 / 1.5 L/min

Cardiotomy reservoir

4,000 / 3,000 / 2,000 ml

Minimum working volume

150 ml

Gas chamber priming

160 / 80 / 50 ml

Thermal chamber priming

80 / 50 / 40 ml

Gas membrane surface area

2 / 1.2 / 0.7 m²

Thermal membrane surface area

0.6 / 0.4 / 0.2 m²

Configuration

Gas and heat exchanger in parallel arrangement

Inlet panel

360° rotating

Air-to-blood ratio

1:1

Gas inlet

Ø6 mm

Water inlet/outlet

Ø16 mm

Presentation

2 units per box

Regulatory standard

Regulation (EU) 2017/745 and Royal Decree 192/2023

Sterility

For exclusive use under medical prescription

Reviews

There are no reviews yet.

Be the first to review “VitaSprings® Membrane Oxygenator (MicroPort® Surgical) for extracorporeal circulation – Models MO-L, MO-M and MO-S for adult, paediatric and infant”

Your email address will not be published. Required fields are marked *