Description
1. Commercial Introduction
The extrication device is the complete solution that every emergency department, ambulance, medicalised unit, civil protection and rescue and extrication team needs to safely immobilise and extract patients. This equipment combines a wraparound, flexible design with a rigid structure that keeps the head-neck-torso axis aligned during the manoeuvre. Distributed by Cahnos in Spain, please contact our technical-commercial team for terms and lead times. For large orders you can request a quote.
2. Technical explanation of the equipment
In emergency immobilisation, proper securing of the torso, head and spine is essential to minimise any segmental movement of the vertebral column in patients with suspected spinal cord injury. This extrication device is wrapped around the patient and closed with a coloured strap with quick-release and hook buckles, allowing rapid placement and immediate release when necessary. The integrated moulded splints provide structural rigidity to the assembly, while its wraparound, flexible design facilitates extraction of patients from hard-to-reach areas, such as wrecked vehicles or confined spaces.
The equipment is made of a washable green fabric that is hygienic and easy to maintain between uses, and is radiolucent, so it does not need to be removed during the patient’s radiological assessment. It is supplied complete with pillow and carrying bag for safekeeping, storage and immediate deployment. It is a Class I medical device in accordance with Regulation (EU) 2017/745.
3. Technical Specifications
3.1. Product data
| Manufacturer | Boscarol |
| Manufacturer reference | YHR-ED01 |
| SKU Cahnos | BRLYHR-ED01 |
| Product | Extrication device for spinal immobilisation |
| Size | Adult |
| Measurements | 85 x 95 x 57 cm |
| Material | Washable green fabric with moulded splints |
| Fixation system | Coloured strap with quick-release and hook buckles |
| Included accessories | Pillow and carrying bag |
| Radiotransparency | Yes (X-ray transparent) |
| Classification | Class I medical device in accordance with Regulation (EU) 2017/745 |
| Application | Immobilisation of torso, head and spine; extraction of patients from hard-to-reach areas |
3.2. Available references
| Manufacturer reference | SKU Cahnos | Description | Size |
|---|---|---|---|
| YHR-ED01 | BRLYHR-ED01 | Extrication device for spinal immobilisation (this product) | Adult |
4. Equivalences and Cross-References
This product corresponds to the manufacturer’s original reference YHR-ED01, marketed by Cahnos under code BRLYHR-ED01 (same product, dual numbering, without additional variants). No verified 1:1 equivalence table with specific codes from other manufacturers is available; the closure system, splints and measurements are specific to each manufacturer. For tenders or equipment fleet comparisons, please consult our technical-commercial department.
Within the Cahnos catalogue, it offers a paediatric version with an analogous function (paediatric spinal immobiliser, in blue fabric), as well as complementary products from the same family of spinal and head immobilisation: the universal head immobiliser WIND series (ref. IMM121640 / BRLIMM121640), the fixation system for spinal boards (ref. IMM121033 / BRLIMM121033) and the replacement sets for chin pads and straps (IMM121664 / BRLIMM121664, IMM121634 / BRLIMM121634, IMM121652 / BRLIMM121652). These references are from the same range or complementary, but not interchangeable 1:1 with the present device.
5. Selection tips and variants of interest
Choose the adult size (85 x 95 x 57 cm) for the general equipment of ambulances and emergency services; for paediatric patients, consider the paediatric spinal immobiliser from the same manufacturer. Complete the immobilisation system with the head immobiliser (WIND series), the cervical collar and the securing straps on the spinal board or rigid stretcher. After each use, wash the fabric according to the manufacturer’s instructions and periodically check the condition of the splints, buckles, seams and straps, immediately replacing worn parts so as not to compromise patient stabilisation. Check terms, lead times and supply volumes with our technical-commercial team.